{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1470239374"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1470239374","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"AN SEM INVESTIGATION INTO THE EFFECTS OF CLINICAL USE ON HEAT-TREATED NICKEL-TITANIUM ROTARY ENDODONTIC FILES","abstract":"Introduction: The third generation of NiTi based rotary files involves a new proprietary thermomechanical process which improves fatigue resistance and flexibility. The purpose of this study was to evaluate the qualitative and quantitative wear/fatigue of three third-generation NiTi rotary endodontic file systems following use in extracted posterior human teeth in a simulated clinical model. Materials and Methods: One hundred files (five packs of five files across four brands: ProFile Vortex™, Vortex Blue™, ProTaper Gold™, and Coltene HyFlex® CM™) were examined with an SEM at the same four positions along their length using a custom-fabricated sample jig before use and through three clinical simulations, and were then evaluated for wear and deformation. Files were categorized as usable, microscopically unacceptable and visually unacceptable. Results: Twelve files visibly failed throughout this study (three separated and eight plastically deformed), and the majority of these failures occurred in the first use of the file. Many instruments were evaluated as microscopically unacceptable before use. A repeated-measures logistic regression analysis found no significant effects for brand, amount of use, and their interaction for files that remained visibly useful. Of those that rated microscopically useful, a significant effect was seen for number of uses (p=0.0127). Contrasts of uses showed significance for use 0 vs. 1, 0 vs. 2, and 0 vs. 3, indicating that unused files were more likely to be microscopically acceptable than used files. No significance was seen between contrasts of uses 1, 2, or 3. Summary and Conclusions: No quantitative wear or distortion pattern specific to any brand was observed that limited multiple file uses. Poor surface condition observed microscopically is not necessarily a precursor to instrument failure. Third-generation controlled memory instruments tend to deform plastically and present minimal risk of clinical separation and canal obstruction through multiple uses.","abstract_html":"Introduction: The third generation of NiTi based rotary files involves a new proprietary thermomechanical process which improves fatigue resistance and flexibility. The purpose of this study was to evaluate the qualitative and quantitative wear/fatigue of three third-generation NiTi rotary endodontic file systems following use in extracted posterior human teeth in a simulated clinical model. Materials and Methods: One hundred files (five packs of five files across four brands: ProFile Vortex™, Vortex Blue™, ProTaper Gold™, and Coltene HyFlex® CM™) were examined with an SEM at the same four positions along their length using a custom-fabricated sample jig before use and through three clinical simulations, and were then evaluated for wear and deformation. Files were categorized as usable, microscopically unacceptable and visually unacceptable. Results: Twelve files visibly failed throughout this study (three separated and eight plastically deformed), and the majority of these failures occurred in the first use of the file. Many instruments were evaluated as microscopically unacceptable before use. A repeated-measures logistic regression analysis found no significant effects for brand, amount of use, and their interaction for files that remained visibly useful. Of those that rated microscopically useful, a significant effect was seen for number of uses (p=0.0127). Contrasts of uses showed significance for use 0 vs. 1, 0 vs. 2, and 0 vs. 3, indicating that unused files were more likely to be microscopically acceptable than used files. No significance was seen between contrasts of uses 1, 2, or 3. Summary and Conclusions: No quantitative wear or distortion pattern specific to any brand was observed that limited multiple file uses. Poor surface condition observed microscopically is not necessarily a precursor to instrument failure. Third-generation controlled memory instruments tend to deform plastically and present minimal risk of clinical separation and canal obstruction through multiple uses.","abstract_has_math":false,"creators":["Burke, Thomas"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Dentistry","degree_department":null,"school":null,"contributors":[],"advisors":["Nusstein, John"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-27T04:41:22Z","subjects":["Dentistry","Nickel-titanium","endodontic","rotary","files","heat-treated","SEM"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1470239374","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1470239374","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1470239374","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1470239374","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Nusstein, John"]},{"key":"dc:creator","label":"Author","values":["Burke, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Nickel-titanium","endodontic","rotary","files","heat-treated","SEM"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1470239374"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Introduction: The third generation of NiTi based rotary files involves a new proprietary thermomechanical process which improves fatigue resistance and flexibility. The purpose of this study was to evaluate the qualitative and quantitative wear/fatigue of three third-generation NiTi rotary endodontic file systems following use in extracted posterior human teeth in a simulated clinical model. Materials and Methods: One hundred files (five packs of five files across four brands: ProFile Vortex™, Vortex Blue™, ProTaper Gold™, and Coltene HyFlex® CM™) were examined with an SEM at the same four positions along their length using a custom-fabricated sample jig before use and through three clinical simulations, and were then evaluated for wear and deformation. Files were categorized as usable, microscopically unacceptable and visually unacceptable. Results: Twelve files visibly failed throughout this study (three separated and eight plastically deformed), and the majority of these failures occurred in the first use of the file. Many instruments were evaluated as microscopically unacceptable before use. A repeated-measures logistic regression analysis found no significant effects for brand, amount of use, and their interaction for files that remained visibly useful. Of those that rated microscopically useful, a significant effect was seen for number of uses (p=0.0127). Contrasts of uses showed significance for use 0 vs. 1, 0 vs. 2, and 0 vs. 3, indicating that unused files were more likely to be microscopically acceptable than used files. No significance was seen between contrasts of uses 1, 2, or 3. Summary and Conclusions: No quantitative wear or distortion pattern specific to any brand was observed that limited multiple file uses. Poor surface condition observed microscopically is not necessarily a precursor to instrument failure. Third-generation controlled memory instruments tend to deform plastically and present minimal risk of clinical separation and canal obstruction through multiple uses."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.98","3.18 MB"]},{"key":"dc:title","label":"Title","values":["AN SEM INVESTIGATION INTO THE EFFECTS OF CLINICAL USE ON HEAT-TREATED NICKEL-TITANIUM ROTARY ENDODONTIC FILES"]}]}],"canonical_facts":{"dc:contributor.advisor":["Nusstein, John"],"dc:creator":["Burke, Thomas"],"dc:date":["2016"],"dc:description":["Introduction: The third generation of NiTi based rotary files involves a new proprietary thermomechanical process which improves fatigue resistance and flexibility. The purpose of this study was to evaluate the qualitative and quantitative wear/fatigue of three third-generation NiTi rotary endodontic file systems following use in extracted posterior human teeth in a simulated clinical model. Materials and Methods: One hundred files (five packs of five files across four brands: ProFile Vortex™, Vortex Blue™, ProTaper Gold™, and Coltene HyFlex® CM™) were examined with an SEM at the same four positions along their length using a custom-fabricated sample jig before use and through three clinical simulations, and were then evaluated for wear and deformation. Files were categorized as usable, microscopically unacceptable and visually unacceptable. Results: Twelve files visibly failed throughout this study (three separated and eight plastically deformed), and the majority of these failures occurred in the first use of the file. Many instruments were evaluated as microscopically unacceptable before use. A repeated-measures logistic regression analysis found no significant effects for brand, amount of use, and their interaction for files that remained visibly useful. Of those that rated microscopically useful, a significant effect was seen for number of uses (p=0.0127). Contrasts of uses showed significance for use 0 vs. 1, 0 vs. 2, and 0 vs. 3, indicating that unused files were more likely to be microscopically acceptable than used files. No significance was seen between contrasts of uses 1, 2, or 3. Summary and Conclusions: No quantitative wear or distortion pattern specific to any brand was observed that limited multiple file uses. Poor surface condition observed microscopically is not necessarily a precursor to instrument failure. Third-generation controlled memory instruments tend to deform plastically and present minimal risk of clinical separation and canal obstruction through multiple uses."],"dc:format":["application/pdf","p.98","3.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1470239374"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Dentistry","Nickel-titanium","endodontic","rotary","files","heat-treated","SEM"],"dc:title":["AN SEM INVESTIGATION INTO THE EFFECTS OF CLINICAL USE ON HEAT-TREATED NICKEL-TITANIUM ROTARY ENDODONTIC FILES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Dentistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:41:22Z"}