{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1471731571"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1471731571","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Probabilistic Performance Assessment of Deteriorating Buried Concrete Sewer Pipes","abstract":"Deterioration in wastewater infrastructure systems is recognized as a serious, worldwide concern. Deterioration due to sulfate attack is one of the primary reasons of functional and structural failures in concrete sewer pipes which is a significant component in wastewater infrastructure systems. Any type of failure may lead to serious health, environmental, and economical issues, lack of the wastewater services, incidents, and traffic delays. The deterioration model presented by Environmental Protection Agency (EPA) is used to obtain the corrosion rate. Subsequently, a time-dependent model is utilized to determine the loss of wall thickness in concrete pipes. In this study, ANSYS is used to construct a nonlinear three-dimensional Finite Element model, which is capable of simulating the behavior of buried concrete sewer pipes under gravity and truck loads. Deterioration of concrete pipe is modeled in ANSYS in such a way that a continuous degradation of the system is considered during the service life of the pipes. A Monte Carlo-based reliability assessment method that uses Latin Hypercube Sampling technique is employed to capture the uncertainties associated with concrete and soil characteristics. The crack width which is the primary reason for leakage in the concrete pipes, is defined as the limit state function, and can be obtained from the tensile stresses on the pipe wall. Hence, the descending portion of stress-strain curve of concrete on the tension side is studied through post-processing of ANSYS results. The results indicate the significant impact of moderate deterioration on the performance and probability of failure of concrete sewer pipes for the serviceability level. In addition, elastic modulus of sidefill and bedding soil are found to have considerable effect on the stress distribution along the deteriorated concrete pipe.","abstract_html":"Deterioration in wastewater infrastructure systems is recognized as a serious, worldwide concern. Deterioration due to sulfate attack is one of the primary reasons of functional and structural failures in concrete sewer pipes which is a significant component in wastewater infrastructure systems. Any type of failure may lead to serious health, environmental, and economical issues, lack of the wastewater services, incidents, and traffic delays. The deterioration model presented by Environmental Protection Agency (EPA) is used to obtain the corrosion rate. Subsequently, a time-dependent model is utilized to determine the loss of wall thickness in concrete pipes. In this study, ANSYS is used to construct a nonlinear three-dimensional Finite Element model, which is capable of simulating the behavior of buried concrete sewer pipes under gravity and truck loads. Deterioration of concrete pipe is modeled in ANSYS in such a way that a continuous degradation of the system is considered during the service life of the pipes. A Monte Carlo-based reliability assessment method that uses Latin Hypercube Sampling technique is employed to capture the uncertainties associated with concrete and soil characteristics. The crack width which is the primary reason for leakage in the concrete pipes, is defined as the limit state function, and can be obtained from the tensile stresses on the pipe wall. Hence, the descending portion of stress-strain curve of concrete on the tension side is studied through post-processing of ANSYS results. The results indicate the significant impact of moderate deterioration on the performance and probability of failure of concrete sewer pipes for the serviceability level. In addition, elastic modulus of sidefill and bedding soil are found to have considerable effect on the stress distribution along the deteriorated concrete pipe.","abstract_has_math":false,"creators":["Zamanian, Soroush, Zamanian"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Shafieezadeh, Absollah"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-27T04:41:22Z","subjects":["Civil Engineering","Water Resource Management","Wastewater Infrastructure Systems, Probabilistic Performance Assessment, Deteriorating Buried Concrete Sewer Pipes"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1471731571","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1471731571","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1471731571","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1471731571","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Shafieezadeh, Absollah"]},{"key":"dc:creator","label":"Author","values":["Zamanian, Soroush, Zamanian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","Water Resource Management","Wastewater Infrastructure Systems, Probabilistic Performance Assessment, Deteriorating Buried Concrete Sewer Pipes"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1471731571"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Deterioration in wastewater infrastructure systems is recognized as a serious, worldwide concern. Deterioration due to sulfate attack is one of the primary reasons of functional and structural failures in concrete sewer pipes which is a significant component in wastewater infrastructure systems. Any type of failure may lead to serious health, environmental, and economical issues, lack of the wastewater services, incidents, and traffic delays. The deterioration model presented by Environmental Protection Agency (EPA) is used to obtain the corrosion rate. Subsequently, a time-dependent model is utilized to determine the loss of wall thickness in concrete pipes. In this study, ANSYS is used to construct a nonlinear three-dimensional Finite Element model, which is capable of simulating the behavior of buried concrete sewer pipes under gravity and truck loads. Deterioration of concrete pipe is modeled in ANSYS in such a way that a continuous degradation of the system is considered during the service life of the pipes. A Monte Carlo-based reliability assessment method that uses Latin Hypercube Sampling technique is employed to capture the uncertainties associated with concrete and soil characteristics. The crack width which is the primary reason for leakage in the concrete pipes, is defined as the limit state function, and can be obtained from the tensile stresses on the pipe wall. Hence, the descending portion of stress-strain curve of concrete on the tension side is studied through post-processing of ANSYS results. The results indicate the significant impact of moderate deterioration on the performance and probability of failure of concrete sewer pipes for the serviceability level. In addition, elastic modulus of sidefill and bedding soil are found to have considerable effect on the stress distribution along the deteriorated concrete pipe."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.108","4.69 MB"]},{"key":"dc:title","label":"Title","values":["Probabilistic Performance Assessment of Deteriorating Buried Concrete Sewer Pipes"]}]}],"canonical_facts":{"dc:contributor.advisor":["Shafieezadeh, Absollah"],"dc:creator":["Zamanian, Soroush, Zamanian"],"dc:date":["2016"],"dc:description":["Deterioration in wastewater infrastructure systems is recognized as a serious, worldwide concern. Deterioration due to sulfate attack is one of the primary reasons of functional and structural failures in concrete sewer pipes which is a significant component in wastewater infrastructure systems. Any type of failure may lead to serious health, environmental, and economical issues, lack of the wastewater services, incidents, and traffic delays. The deterioration model presented by Environmental Protection Agency (EPA) is used to obtain the corrosion rate. Subsequently, a time-dependent model is utilized to determine the loss of wall thickness in concrete pipes. In this study, ANSYS is used to construct a nonlinear three-dimensional Finite Element model, which is capable of simulating the behavior of buried concrete sewer pipes under gravity and truck loads. Deterioration of concrete pipe is modeled in ANSYS in such a way that a continuous degradation of the system is considered during the service life of the pipes. A Monte Carlo-based reliability assessment method that uses Latin Hypercube Sampling technique is employed to capture the uncertainties associated with concrete and soil characteristics. The crack width which is the primary reason for leakage in the concrete pipes, is defined as the limit state function, and can be obtained from the tensile stresses on the pipe wall. Hence, the descending portion of stress-strain curve of concrete on the tension side is studied through post-processing of ANSYS results. The results indicate the significant impact of moderate deterioration on the performance and probability of failure of concrete sewer pipes for the serviceability level. In addition, elastic modulus of sidefill and bedding soil are found to have considerable effect on the stress distribution along the deteriorated concrete pipe."],"dc:format":["application/pdf","p.108","4.69 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1471731571"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Civil Engineering","Water Resource Management","Wastewater Infrastructure Systems, Probabilistic Performance Assessment, Deteriorating Buried Concrete Sewer Pipes"],"dc:title":["Probabilistic Performance Assessment of Deteriorating Buried Concrete Sewer Pipes"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:41:22Z"}