{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1574422948246589"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1574422948246589","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Simulation-Based Stability Tests in Total Knee Arthroplasty: Are Component Alignment, KneeLaxity, and Tibiofemoral Contact Forces Related?","abstract":"Total knee arthroplasty (TKA) is known to be a successful procedure that can treat pain and disfunctioncaused by knee osteoarthritis (KOA). However, approximately 20% of patients are dissatisfied aftersurgery, with complications that have been linked to variable intraoperative procedures such asprosthetic component alignment and soft-tissue balancing techniques. The concept of kinematicalignment has been introduced to serve as an alternative to traditional mechanical alignment, where allpatients’ bone cuts are made in the same way to restore a straight hip-knee-ankle line. Kinematicalignment instead aims to restore the anatomy of the native knee, without the need to balance the softtissues. While many methods regarding soft-tissue balancing are subjective to surgeon decisions, newtechnology released by OrthoSensor serves to take tibiofemoral force measurements in eachcompartment of the knee during a passive range of motion, claiming that equal contact forces withinvarious thresholds presume knee balance. However, biomechanical knee balance is defined using theamount of knee motion resulting from a known applied force, which we have quantified with a novelknee stability device. The purpose of this study was to investigate the relationship of these contact forcemeasurements to biomechanical knee laxity and prosthetic component alignment, as well as to explorethe clinical utility of using contact forces and component alignments to predict knee laxity. Theserelationships were explored by creating a model of the lower limb in OpenSim 4.0 that incorporatedcontact meshes of the prosthetic components and varying properties of ligament stiffnesses torepresent five different types of knees. 790 forward dynamic simulations were run at multiple flexionangles, applying increasing and decreasing torque to move the knee in the varus-valgus direction.Correlations were calculated between contact forces, knee laxity, and component alignment, and forward step-wise regressions were done to try to predict laxity using inputs of contact and alignment.Balanced contact forces did not show a consistent association with balanced knee laxity, but highercontact forces were generally associated with decreased laxity. However, contact measurements did nothave a consistent significant effect in the prediction of knee laxity, which adds to the lack of support forthe utilization of these measurements. Tibiofemoral contact was also quite sensitive to componentalignment changes, which supports the idea that kinematically-aligned TKAs should not use a forcetarget when balancing the knee, as patient-specific alignment entails patient-specific contact forces.Overall, the relationships between tibiofemoral contact and biomechanical knee function wereinconsistent and therefore the use of these contact forces in soft-tissue balancing is not supported.More research should be done in modeling these forces during daily activities to explore a relationshipbetween contact forces and active functionality.","abstract_html":"Total knee arthroplasty (TKA) is known to be a successful procedure that can treat pain and disfunctioncaused by knee osteoarthritis (KOA). However, approximately 20% of patients are dissatisfied aftersurgery, with complications that have been linked to variable intraoperative procedures such asprosthetic component alignment and soft-tissue balancing techniques. The concept of kinematicalignment has been introduced to serve as an alternative to traditional mechanical alignment, where allpatients’ bone cuts are made in the same way to restore a straight hip-knee-ankle line. Kinematicalignment instead aims to restore the anatomy of the native knee, without the need to balance the softtissues. While many methods regarding soft-tissue balancing are subjective to surgeon decisions, newtechnology released by OrthoSensor serves to take tibiofemoral force measurements in eachcompartment of the knee during a passive range of motion, claiming that equal contact forces withinvarious thresholds presume knee balance. However, biomechanical knee balance is defined using theamount of knee motion resulting from a known applied force, which we have quantified with a novelknee stability device. The purpose of this study was to investigate the relationship of these contact forcemeasurements to biomechanical knee laxity and prosthetic component alignment, as well as to explorethe clinical utility of using contact forces and component alignments to predict knee laxity. Theserelationships were explored by creating a model of the lower limb in OpenSim 4.0 that incorporatedcontact meshes of the prosthetic components and varying properties of ligament stiffnesses torepresent five different types of knees. 790 forward dynamic simulations were run at multiple flexionangles, applying increasing and decreasing torque to move the knee in the varus-valgus direction.Correlations were calculated between contact forces, knee laxity, and component alignment, and forward step-wise regressions were done to try to predict laxity using inputs of contact and alignment.Balanced contact forces did not show a consistent association with balanced knee laxity, but highercontact forces were generally associated with decreased laxity. However, contact measurements did nothave a consistent significant effect in the prediction of knee laxity, which adds to the lack of support forthe utilization of these measurements. Tibiofemoral contact was also quite sensitive to componentalignment changes, which supports the idea that kinematically-aligned TKAs should not use a forcetarget when balancing the knee, as patient-specific alignment entails patient-specific contact forces.Overall, the relationships between tibiofemoral contact and biomechanical knee function wereinconsistent and therefore the use of these contact forces in soft-tissue balancing is not supported.More research should be done in modeling these forces during daily activities to explore a relationshipbetween contact forces and active functionality.","abstract_has_math":false,"creators":["Delventhal, Brooke"],"institution":"The Ohio State University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Siston, Robert"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-26T06:39:17Z","subjects":["Mechanical Engineering","total knee arthroplasty","knee laxity","tibiofemoral contact","prosthetic component alignment","soft-tissue balancing"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1574422948246589","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1574422948246589","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1574422948246589","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1574422948246589","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Siston, Robert"]},{"key":"dc:creator","label":"Author","values":["Delventhal, Brooke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","total knee arthroplasty","knee laxity","tibiofemoral contact","prosthetic component alignment","soft-tissue balancing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1574422948246589"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Total knee arthroplasty (TKA) is known to be a successful procedure that can treat pain and disfunctioncaused by knee osteoarthritis (KOA). However, approximately 20% of patients are dissatisfied aftersurgery, with complications that have been linked to variable intraoperative procedures such asprosthetic component alignment and soft-tissue balancing techniques. The concept of kinematicalignment has been introduced to serve as an alternative to traditional mechanical alignment, where allpatients’ bone cuts are made in the same way to restore a straight hip-knee-ankle line. Kinematicalignment instead aims to restore the anatomy of the native knee, without the need to balance the softtissues. While many methods regarding soft-tissue balancing are subjective to surgeon decisions, newtechnology released by OrthoSensor serves to take tibiofemoral force measurements in eachcompartment of the knee during a passive range of motion, claiming that equal contact forces withinvarious thresholds presume knee balance. However, biomechanical knee balance is defined using theamount of knee motion resulting from a known applied force, which we have quantified with a novelknee stability device. The purpose of this study was to investigate the relationship of these contact forcemeasurements to biomechanical knee laxity and prosthetic component alignment, as well as to explorethe clinical utility of using contact forces and component alignments to predict knee laxity. Theserelationships were explored by creating a model of the lower limb in OpenSim 4.0 that incorporatedcontact meshes of the prosthetic components and varying properties of ligament stiffnesses torepresent five different types of knees. 790 forward dynamic simulations were run at multiple flexionangles, applying increasing and decreasing torque to move the knee in the varus-valgus direction.Correlations were calculated between contact forces, knee laxity, and component alignment, and forward step-wise regressions were done to try to predict laxity using inputs of contact and alignment.Balanced contact forces did not show a consistent association with balanced knee laxity, but highercontact forces were generally associated with decreased laxity. However, contact measurements did nothave a consistent significant effect in the prediction of knee laxity, which adds to the lack of support forthe utilization of these measurements. Tibiofemoral contact was also quite sensitive to componentalignment changes, which supports the idea that kinematically-aligned TKAs should not use a forcetarget when balancing the knee, as patient-specific alignment entails patient-specific contact forces.Overall, the relationships between tibiofemoral contact and biomechanical knee function wereinconsistent and therefore the use of these contact forces in soft-tissue balancing is not supported.More research should be done in modeling these forces during daily activities to explore a relationshipbetween contact forces and active functionality."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.85","1.7 MB"]},{"key":"dc:title","label":"Title","values":["Simulation-Based Stability Tests in Total Knee Arthroplasty: Are Component Alignment, KneeLaxity, and Tibiofemoral Contact Forces Related?"]}]}],"canonical_facts":{"dc:contributor":["Siston, Robert"],"dc:creator":["Delventhal, Brooke"],"dc:date":["2019"],"dc:description":["Total knee arthroplasty (TKA) is known to be a successful procedure that can treat pain and disfunctioncaused by knee osteoarthritis (KOA). However, approximately 20% of patients are dissatisfied aftersurgery, with complications that have been linked to variable intraoperative procedures such asprosthetic component alignment and soft-tissue balancing techniques. The concept of kinematicalignment has been introduced to serve as an alternative to traditional mechanical alignment, where allpatients’ bone cuts are made in the same way to restore a straight hip-knee-ankle line. Kinematicalignment instead aims to restore the anatomy of the native knee, without the need to balance the softtissues. While many methods regarding soft-tissue balancing are subjective to surgeon decisions, newtechnology released by OrthoSensor serves to take tibiofemoral force measurements in eachcompartment of the knee during a passive range of motion, claiming that equal contact forces withinvarious thresholds presume knee balance. However, biomechanical knee balance is defined using theamount of knee motion resulting from a known applied force, which we have quantified with a novelknee stability device. The purpose of this study was to investigate the relationship of these contact forcemeasurements to biomechanical knee laxity and prosthetic component alignment, as well as to explorethe clinical utility of using contact forces and component alignments to predict knee laxity. Theserelationships were explored by creating a model of the lower limb in OpenSim 4.0 that incorporatedcontact meshes of the prosthetic components and varying properties of ligament stiffnesses torepresent five different types of knees. 790 forward dynamic simulations were run at multiple flexionangles, applying increasing and decreasing torque to move the knee in the varus-valgus direction.Correlations were calculated between contact forces, knee laxity, and component alignment, and forward step-wise regressions were done to try to predict laxity using inputs of contact and alignment.Balanced contact forces did not show a consistent association with balanced knee laxity, but highercontact forces were generally associated with decreased laxity. However, contact measurements did nothave a consistent significant effect in the prediction of knee laxity, which adds to the lack of support forthe utilization of these measurements. Tibiofemoral contact was also quite sensitive to componentalignment changes, which supports the idea that kinematically-aligned TKAs should not use a forcetarget when balancing the knee, as patient-specific alignment entails patient-specific contact forces.Overall, the relationships between tibiofemoral contact and biomechanical knee function wereinconsistent and therefore the use of these contact forces in soft-tissue balancing is not supported.More research should be done in modeling these forces during daily activities to explore a relationshipbetween contact forces and active functionality."],"dc:format":["application/pdf","p.85","1.7 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1574422948246589"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","total knee arthroplasty","knee laxity","tibiofemoral contact","prosthetic component alignment","soft-tissue balancing"],"dc:title":["Simulation-Based Stability Tests in Total Knee Arthroplasty: Are Component Alignment, KneeLaxity, and Tibiofemoral Contact Forces Related?"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-26T06:39:17Z"}