{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:osu1720612866047653"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:osu1720612866047653","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Separation of Nanoscale Iron Oxide Particles and Biological Materials using Permanent Magnet-basedSystems","abstract":"Superparamagnetic iron oxide nanoparticles (SPIONs) are crucial in biomedical and chemical engineering applications, including wastewater management, bio-detection, biological imaging, targeted drug delivery, and bio-sensing. However, magnetic separation of SPIONs, especially those smaller than 50 nm, is challenging due to thermal energy and viscous drag hindering magnetophoretic motion. This study explores the magnetically facilitated sedimentation of SPIONs (5–30 nm) by applying high magnetic fields and gradients two magnetic sorters. Experimental data, validated by in-situ Small Angle X-ray scattering (SAXS), show that only the 30 nm particles experienced particle aggregation or agglomeration, indicating that dipole–dipole interactions did not play a discernable role in the separation process for particles smaller than ∼15 nm.. Variables such as initial SPION concentration, temperature, magnetic field strength, and gradient were evaluated. Additionally, numerical simulations confirmed that even SPIONs smaller than 15 nm exhibit effective magnetophoresis, counteracting Brownian motion.Moreover, we demonstrate the application of a magnetic filtration model for red blood cell (RBCs) separation using high gradient magnetic separation (HGMS) packed columns. The study investigates flow rate, cell concentration, and external field strength,iishowing that varying the magnetic field produces an exponential increase in the magnetic energy gradient. The binary separation capability of paramagnetic methemoglobin-containing RBCs from diamagnetic oxyhemoglobin-containing RBCs was confirmed, achieving 99% purity in isolated cells. This work underscores the utility of magnetic filtration for biological separations and its scalability potential.","abstract_html":"Superparamagnetic iron oxide nanoparticles (SPIONs) are crucial in biomedical and chemical engineering applications, including wastewater management, bio-detection, biological imaging, targeted drug delivery, and bio-sensing. However, magnetic separation of SPIONs, especially those smaller than 50 nm, is challenging due to thermal energy and viscous drag hindering magnetophoretic motion. This study explores the magnetically facilitated sedimentation of SPIONs (5–30 nm) by applying high magnetic fields and gradients two magnetic sorters. Experimental data, validated by in-situ Small Angle X-ray scattering (SAXS), show that only the 30 nm particles experienced particle aggregation or agglomeration, indicating that dipole–dipole interactions did not play a discernable role in the separation process for particles smaller than ∼15 nm.. Variables such as initial SPION concentration, temperature, magnetic field strength, and gradient were evaluated. Additionally, numerical simulations confirmed that even SPIONs smaller than 15 nm exhibit effective magnetophoresis, counteracting Brownian motion.Moreover, we demonstrate the application of a magnetic filtration model for red blood cell (RBCs) separation using high gradient magnetic separation (HGMS) packed columns. The study investigates flow rate, cell concentration, and external field strength,iishowing that varying the magnetic field produces an exponential increase in the magnetic energy gradient. The binary separation capability of paramagnetic methemoglobin-containing RBCs from diamagnetic oxyhemoglobin-containing RBCs was confirmed, achieving 99% purity in isolated cells. This work underscores the utility of magnetic filtration for biological separations and its scalability potential.","abstract_has_math":false,"creators":["Wu, Xian"],"institution":"The Ohio State University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Chalmers, Jeffrey"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-09-19","date_published":"2024-09-19","updated_at":"2026-11-27T04:59:23Z","subjects":["Chemical Engineering"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1720612866047653","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=osu1720612866047653","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aosu1720612866047653","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aosu1720612866047653","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chalmers, Jeffrey"]},{"key":"dc:creator","label":"Author","values":["Wu, Xian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-09-19"]},{"key":"dc:publisher","label":"Institution","values":["The Ohio State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["The Ohio State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1720612866047653"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Superparamagnetic iron oxide nanoparticles (SPIONs) are crucial in biomedical and chemical engineering applications, including wastewater management, bio-detection, biological imaging, targeted drug delivery, and bio-sensing. However, magnetic separation of SPIONs, especially those smaller than 50 nm, is challenging due to thermal energy and viscous drag hindering magnetophoretic motion. This study explores the magnetically facilitated sedimentation of SPIONs (5–30 nm) by applying high magnetic fields and gradients two magnetic sorters. Experimental data, validated by in-situ Small Angle X-ray scattering (SAXS), show that only the 30 nm particles experienced particle aggregation or agglomeration, indicating that dipole–dipole interactions did not play a discernable role in the separation process for particles smaller than ∼15 nm.. Variables such as initial SPION concentration, temperature, magnetic field strength, and gradient were evaluated. Additionally, numerical simulations confirmed that even SPIONs smaller than 15 nm exhibit effective magnetophoresis, counteracting Brownian motion.Moreover, we demonstrate the application of a magnetic filtration model for red blood cell (RBCs) separation using high gradient magnetic separation (HGMS) packed columns. The study investigates flow rate, cell concentration, and external field strength,iishowing that varying the magnetic field produces an exponential increase in the magnetic energy gradient. The binary separation capability of paramagnetic methemoglobin-containing RBCs from diamagnetic oxyhemoglobin-containing RBCs was confirmed, achieving 99% purity in isolated cells. This work underscores the utility of magnetic filtration for biological separations and its scalability potential."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.245","6.82 MB"]},{"key":"dc:title","label":"Title","values":["Separation of Nanoscale Iron Oxide Particles and Biological Materials using Permanent Magnet-basedSystems"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chalmers, Jeffrey"],"dc:creator":["Wu, Xian"],"dc:date":["2024-09-19"],"dc:description":["Superparamagnetic iron oxide nanoparticles (SPIONs) are crucial in biomedical and chemical engineering applications, including wastewater management, bio-detection, biological imaging, targeted drug delivery, and bio-sensing. However, magnetic separation of SPIONs, especially those smaller than 50 nm, is challenging due to thermal energy and viscous drag hindering magnetophoretic motion. This study explores the magnetically facilitated sedimentation of SPIONs (5–30 nm) by applying high magnetic fields and gradients two magnetic sorters. Experimental data, validated by in-situ Small Angle X-ray scattering (SAXS), show that only the 30 nm particles experienced particle aggregation or agglomeration, indicating that dipole–dipole interactions did not play a discernable role in the separation process for particles smaller than ∼15 nm.. Variables such as initial SPION concentration, temperature, magnetic field strength, and gradient were evaluated. Additionally, numerical simulations confirmed that even SPIONs smaller than 15 nm exhibit effective magnetophoresis, counteracting Brownian motion.Moreover, we demonstrate the application of a magnetic filtration model for red blood cell (RBCs) separation using high gradient magnetic separation (HGMS) packed columns. The study investigates flow rate, cell concentration, and external field strength,iishowing that varying the magnetic field produces an exponential increase in the magnetic energy gradient. The binary separation capability of paramagnetic methemoglobin-containing RBCs from diamagnetic oxyhemoglobin-containing RBCs was confirmed, achieving 99% purity in isolated cells. This work underscores the utility of magnetic filtration for biological separations and its scalability potential."],"dc:format":["application/pdf","p.245","6.82 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=osu1720612866047653"],"dc:language":["English"],"dc:publisher":["The Ohio State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Chemical Engineering"],"dc:title":["Separation of Nanoscale Iron Oxide Particles and Biological Materials using Permanent Magnet-basedSystems"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["The Ohio State University"]},"updated_at":"2026-11-27T04:59:23Z"}