{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:toledo1471543246"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:toledo1471543246","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"An Evaluation of Corrosion Sensors for the Monitoring of the Main Cables of the Anthony Wayne Bridge","abstract":"The Anthony Wayne Bridge is a suspension bridge located in Toledo, Ohio currently undergoing an extensive rehabilitation project. Internal inspection revealed corrosion of the steel wires within the bridge’s main cable. The bridge operators have elected to pursue the installation of a dehumidification system. Such a system injects dry air into the cable to lower the relative humidity and stop the corrosion process. The research presented in this thesis investigates the use of the Analtom AN110 corrosion sensor and its applications on the Anthony Wayne Bridge. Dehumidification systems require extensive monitoring systems to ensure their effectiveness and proper operation. The AN110 corrosion sensor uses linear polarization resistance (LPR) technology to measure corrosion rates in real time. Such measurements could potentially provide data valuable in ensuring the effectiveness and progress of the drying-out process. Included is an extensive review of the bridge’s rehabilitation process, a literature review of dehumidification and the application of LPR technology, and laboratory testing of the corrosion sensor. Laboratory testing involved the exposure of the sensor to cyclic relative humidity to observe the relationship between corrosion rate and relative humidity. The use of the AN110 corrosion sensor in the monitoring of the future dehumidification system on the Anthony Wayne Bridge is recommended. Among other factors, testing results showed a clear and consistent relationship between the recorded corrosion rate and the relative humidity. The sensor functions as expected and confirms the existing understanding of the effect of relative humidity on the corrosion of steel.","abstract_html":"The Anthony Wayne Bridge is a suspension bridge located in Toledo, Ohio currently undergoing an extensive rehabilitation project. Internal inspection revealed corrosion of the steel wires within the bridge’s main cable. The bridge operators have elected to pursue the installation of a dehumidification system. Such a system injects dry air into the cable to lower the relative humidity and stop the corrosion process. The research presented in this thesis investigates the use of the Analtom AN110 corrosion sensor and its applications on the Anthony Wayne Bridge. Dehumidification systems require extensive monitoring systems to ensure their effectiveness and proper operation. The AN110 corrosion sensor uses linear polarization resistance (LPR) technology to measure corrosion rates in real time. Such measurements could potentially provide data valuable in ensuring the effectiveness and progress of the drying-out process. Included is an extensive review of the bridge’s rehabilitation process, a literature review of dehumidification and the application of LPR technology, and laboratory testing of the corrosion sensor. Laboratory testing involved the exposure of the sensor to cyclic relative humidity to observe the relationship between corrosion rate and relative humidity. The use of the AN110 corrosion sensor in the monitoring of the future dehumidification system on the Anthony Wayne Bridge is recommended. Among other factors, testing results showed a clear and consistent relationship between the recorded corrosion rate and the relative humidity. The sensor functions as expected and confirms the existing understanding of the effect of relative humidity on the corrosion of steel.","abstract_has_math":false,"creators":["Colony, Charles W., Colony"],"institution":"University of Toledo","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Nims, Douglas"],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-27T04:41:22Z","subjects":["Civil Engineering","linear polarization corrosion Anthony Wayne Bridge dehumidification LPR bridge"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=toledo1471543246","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=toledo1471543246","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Atoledo1471543246","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Atoledo1471543246","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Nims, Douglas"]},{"key":"dc:creator","label":"Author","values":["Colony, Charles W., Colony"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016"]},{"key":"dc:publisher","label":"Institution","values":["University of Toledo / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Toledo"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","linear polarization corrosion Anthony Wayne Bridge dehumidification LPR bridge"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=toledo1471543246"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The Anthony Wayne Bridge is a suspension bridge located in Toledo, Ohio currently undergoing an extensive rehabilitation project. Internal inspection revealed corrosion of the steel wires within the bridge’s main cable. The bridge operators have elected to pursue the installation of a dehumidification system. Such a system injects dry air into the cable to lower the relative humidity and stop the corrosion process. The research presented in this thesis investigates the use of the Analtom AN110 corrosion sensor and its applications on the Anthony Wayne Bridge. Dehumidification systems require extensive monitoring systems to ensure their effectiveness and proper operation. The AN110 corrosion sensor uses linear polarization resistance (LPR) technology to measure corrosion rates in real time. Such measurements could potentially provide data valuable in ensuring the effectiveness and progress of the drying-out process. Included is an extensive review of the bridge’s rehabilitation process, a literature review of dehumidification and the application of LPR technology, and laboratory testing of the corrosion sensor. Laboratory testing involved the exposure of the sensor to cyclic relative humidity to observe the relationship between corrosion rate and relative humidity. The use of the AN110 corrosion sensor in the monitoring of the future dehumidification system on the Anthony Wayne Bridge is recommended. Among other factors, testing results showed a clear and consistent relationship between the recorded corrosion rate and the relative humidity. The sensor functions as expected and confirms the existing understanding of the effect of relative humidity on the corrosion of steel."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.59","1.47 MB"]},{"key":"dc:title","label":"Title","values":["An Evaluation of Corrosion Sensors for the Monitoring of the Main Cables of the Anthony Wayne Bridge"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Nims, Douglas"],"dc:creator":["Colony, Charles W., Colony"],"dc:date":["2016"],"dc:description":["The Anthony Wayne Bridge is a suspension bridge located in Toledo, Ohio currently undergoing an extensive rehabilitation project. Internal inspection revealed corrosion of the steel wires within the bridge’s main cable. The bridge operators have elected to pursue the installation of a dehumidification system. Such a system injects dry air into the cable to lower the relative humidity and stop the corrosion process. The research presented in this thesis investigates the use of the Analtom AN110 corrosion sensor and its applications on the Anthony Wayne Bridge. Dehumidification systems require extensive monitoring systems to ensure their effectiveness and proper operation. The AN110 corrosion sensor uses linear polarization resistance (LPR) technology to measure corrosion rates in real time. Such measurements could potentially provide data valuable in ensuring the effectiveness and progress of the drying-out process. Included is an extensive review of the bridge’s rehabilitation process, a literature review of dehumidification and the application of LPR technology, and laboratory testing of the corrosion sensor. Laboratory testing involved the exposure of the sensor to cyclic relative humidity to observe the relationship between corrosion rate and relative humidity. The use of the AN110 corrosion sensor in the monitoring of the future dehumidification system on the Anthony Wayne Bridge is recommended. Among other factors, testing results showed a clear and consistent relationship between the recorded corrosion rate and the relative humidity. The sensor functions as expected and confirms the existing understanding of the effect of relative humidity on the corrosion of steel."],"dc:format":["application/pdf","p.59","1.47 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=toledo1471543246"],"dc:language":["English"],"dc:publisher":["University of Toledo / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Civil Engineering","linear polarization corrosion Anthony Wayne Bridge dehumidification LPR bridge"],"dc:title":["An Evaluation of Corrosion Sensors for the Monitoring of the Main Cables of the Anthony Wayne Bridge"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["University of Toledo"]},"updated_at":"2026-11-27T04:41:22Z"}