{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1005757573"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1005757573","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"OPTIMAL LOCATIONS OF BOOSTER STATIONS IN WATER DISTRIBUTION SYSTEMS","abstract":"Disinfectant residual maintenance has been always a concern to the utilities. Booster disinfection is a strategy that is being applied to add disinfectants at strategic locations throughout a water distribution system. A designer needs information about the network for the location and operation of booster stations. This thesis describes the development and investigation of a method that would be able to estimate and identify, with some degree of accuracy, minimum location of booster stations that are practicable for real distribution networks. The model formulation is related to a general facility location problem, which uses a branch and bound solution procedure. The design objectives considered are (1) minimize the number of booster stations and (2) maximize the uniformity of the residual demand in the network. The random inputs to the model are set of potential booster locations and desired residual demand for a given system. The design method is applied to a real distribution network. Results illustrationg the tradeoffs between the objectives suggest that to maintain a higher and uniform residual demand in the network, more number of booster stations are required. For varied input set of potential booster stations, different solution sets of optimal booster locations can achieve the same residual demand. The designer has to consider the extent of residual coverage that each booster station attains and the amount of overlapping influences that takes place between the operation of the booster stations. These tradeoffs are an important factor in the network design unless the cost is of limited concern.","abstract_html":"Disinfectant residual maintenance has been always a concern to the utilities. Booster disinfection is a strategy that is being applied to add disinfectants at strategic locations throughout a water distribution system. A designer needs information about the network for the location and operation of booster stations. This thesis describes the development and investigation of a method that would be able to estimate and identify, with some degree of accuracy, minimum location of booster stations that are practicable for real distribution networks. The model formulation is related to a general facility location problem, which uses a branch and bound solution procedure. The design objectives considered are (1) minimize the number of booster stations and (2) maximize the uniformity of the residual demand in the network. The random inputs to the model are set of potential booster locations and desired residual demand for a given system. The design method is applied to a real distribution network. Results illustrationg the tradeoffs between the objectives suggest that to maintain a higher and uniform residual demand in the network, more number of booster stations are required. For varied input set of potential booster stations, different solution sets of optimal booster locations can achieve the same residual demand. The designer has to consider the extent of residual coverage that each booster station attains and the amount of overlapping influences that takes place between the operation of the booster stations. These tradeoffs are an important factor in the network design unless the cost is of limited concern.","abstract_has_math":false,"creators":["SUBRAMANIAM, PRATHIBA"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Uber, Dr. James G."],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001-12-03","date_published":"2001-12-03","updated_at":"2026-11-27T04:36:41Z","subjects":["Engineering, Environmental","water distribution systems","booster disinfection","optimal control of chlorine"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1005757573","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1005757573","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1005757573","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1005757573","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Uber, Dr. James G."]},{"key":"dc:creator","label":"Author","values":["SUBRAMANIAM, PRATHIBA"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2001-12-03"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Environmental","water distribution systems","booster disinfection","optimal control of chlorine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1005757573"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Disinfectant residual maintenance has been always a concern to the utilities. Booster disinfection is a strategy that is being applied to add disinfectants at strategic locations throughout a water distribution system. A designer needs information about the network for the location and operation of booster stations. This thesis describes the development and investigation of a method that would be able to estimate and identify, with some degree of accuracy, minimum location of booster stations that are practicable for real distribution networks. The model formulation is related to a general facility location problem, which uses a branch and bound solution procedure. The design objectives considered are (1) minimize the number of booster stations and (2) maximize the uniformity of the residual demand in the network. The random inputs to the model are set of potential booster locations and desired residual demand for a given system. The design method is applied to a real distribution network. Results illustrationg the tradeoffs between the objectives suggest that to maintain a higher and uniform residual demand in the network, more number of booster stations are required. For varied input set of potential booster stations, different solution sets of optimal booster locations can achieve the same residual demand. The designer has to consider the extent of residual coverage that each booster station attains and the amount of overlapping influences that takes place between the operation of the booster stations. These tradeoffs are an important factor in the network design unless the cost is of limited concern."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.65","1.58 MB"]},{"key":"dc:title","label":"Title","values":["OPTIMAL LOCATIONS OF BOOSTER STATIONS IN WATER DISTRIBUTION SYSTEMS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Uber, Dr. James G."],"dc:creator":["SUBRAMANIAM, PRATHIBA"],"dc:date":["2001-12-03"],"dc:description":["Disinfectant residual maintenance has been always a concern to the utilities. Booster disinfection is a strategy that is being applied to add disinfectants at strategic locations throughout a water distribution system. A designer needs information about the network for the location and operation of booster stations. This thesis describes the development and investigation of a method that would be able to estimate and identify, with some degree of accuracy, minimum location of booster stations that are practicable for real distribution networks. The model formulation is related to a general facility location problem, which uses a branch and bound solution procedure. The design objectives considered are (1) minimize the number of booster stations and (2) maximize the uniformity of the residual demand in the network. The random inputs to the model are set of potential booster locations and desired residual demand for a given system. The design method is applied to a real distribution network. Results illustrationg the tradeoffs between the objectives suggest that to maintain a higher and uniform residual demand in the network, more number of booster stations are required. For varied input set of potential booster stations, different solution sets of optimal booster locations can achieve the same residual demand. The designer has to consider the extent of residual coverage that each booster station attains and the amount of overlapping influences that takes place between the operation of the booster stations. These tradeoffs are an important factor in the network design unless the cost is of limited concern."],"dc:format":["application/pdf","p.65","1.58 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1005757573"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Environmental","water distribution systems","booster disinfection","optimal control of chlorine"],"dc:title":["OPTIMAL LOCATIONS OF BOOSTER STATIONS IN WATER DISTRIBUTION SYSTEMS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Environmental Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:36:41Z"}