{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1042051817"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1042051817","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"ENVIRONMENTAL CONDITIONING AND TESTING OF THREE FIBER REINFORCED POLYMER PANELS","abstract":"Three types of fiber reinforced polymer bridge deck panels were supplied to the University of Cincinnati. Specimens included were small-size specimens supplied by their respective manufacturers and full-size specimens obtained from the Salem Avenue bridge in Dayton, Ohio. Research performed includes: long-term environmental monitoring, load testing, and finite-element analysis. Long-term environmental monitoring was performed on small-size specimens for all three deck types. Environmental monitoring included collection of temperature and strain data over a period of nine months. Average internal mperature, coefficient of thermal expansion (in both directions), and temperature gradient were calculated for each type of panel. Load testing was performed at the University of Cincinnati Large Scale Test Facility (UCLSTF). Load tests were performed on small-size specimens and full-size specimens obtained from a bridge retrofit project. Effective flexural and shear stiffness were calculated for each panel tested. Failure load and failure type for each test are reported. Finally, a finite-element model of a full-size panel was created for one of the deck types in order to capture the effects of internal damages. Analysis results of the finite-element model are compared against experimental results.","abstract_html":"Three types of fiber reinforced polymer bridge deck panels were supplied to the University of Cincinnati. Specimens included were small-size specimens supplied by their respective manufacturers and full-size specimens obtained from the Salem Avenue bridge in Dayton, Ohio. Research performed includes: long-term environmental monitoring, load testing, and finite-element analysis. Long-term environmental monitoring was performed on small-size specimens for all three deck types. Environmental monitoring included collection of temperature and strain data over a period of nine months. Average internal mperature, coefficient of thermal expansion (in both directions), and temperature gradient were calculated for each type of panel. Load testing was performed at the University of Cincinnati Large Scale Test Facility (UCLSTF). Load tests were performed on small-size specimens and full-size specimens obtained from a bridge retrofit project. Effective flexural and shear stiffness were calculated for each panel tested. Failure load and failure type for each test are reported. Finally, a finite-element model of a full-size panel was created for one of the deck types in order to capture the effects of internal damages. Analysis results of the finite-element model are compared against experimental results.","abstract_has_math":false,"creators":["NEUMANN, ANDREW ROBERT"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Shahrooz, Dr. Bahram"],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-01-22","date_published":"2003-01-22","updated_at":"2026-11-27T04:36:45Z","subjects":["Engineering, Civil","fiber reinforced polymers","bridge decks","load testing","finite element model","thermal expansion"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1042051817","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1042051817","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1042051817","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1042051817","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Shahrooz, Dr. Bahram"]},{"key":"dc:creator","label":"Author","values":["NEUMANN, ANDREW ROBERT"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2003-01-22"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Civil","fiber reinforced polymers","bridge decks","load testing","finite element model","thermal expansion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1042051817"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Three types of fiber reinforced polymer bridge deck panels were supplied to the University of Cincinnati. Specimens included were small-size specimens supplied by their respective manufacturers and full-size specimens obtained from the Salem Avenue bridge in Dayton, Ohio. Research performed includes: long-term environmental monitoring, load testing, and finite-element analysis. Long-term environmental monitoring was performed on small-size specimens for all three deck types. Environmental monitoring included collection of temperature and strain data over a period of nine months. Average internal mperature, coefficient of thermal expansion (in both directions), and temperature gradient were calculated for each type of panel. Load testing was performed at the University of Cincinnati Large Scale Test Facility (UCLSTF). Load tests were performed on small-size specimens and full-size specimens obtained from a bridge retrofit project. Effective flexural and shear stiffness were calculated for each panel tested. Failure load and failure type for each test are reported. Finally, a finite-element model of a full-size panel was created for one of the deck types in order to capture the effects of internal damages. Analysis results of the finite-element model are compared against experimental results."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.201","12.64 MB"]},{"key":"dc:title","label":"Title","values":["ENVIRONMENTAL CONDITIONING AND TESTING OF THREE FIBER REINFORCED POLYMER PANELS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Shahrooz, Dr. Bahram"],"dc:creator":["NEUMANN, ANDREW ROBERT"],"dc:date":["2003-01-22"],"dc:description":["Three types of fiber reinforced polymer bridge deck panels were supplied to the University of Cincinnati. Specimens included were small-size specimens supplied by their respective manufacturers and full-size specimens obtained from the Salem Avenue bridge in Dayton, Ohio. Research performed includes: long-term environmental monitoring, load testing, and finite-element analysis. Long-term environmental monitoring was performed on small-size specimens for all three deck types. Environmental monitoring included collection of temperature and strain data over a period of nine months. Average internal mperature, coefficient of thermal expansion (in both directions), and temperature gradient were calculated for each type of panel. Load testing was performed at the University of Cincinnati Large Scale Test Facility (UCLSTF). Load tests were performed on small-size specimens and full-size specimens obtained from a bridge retrofit project. Effective flexural and shear stiffness were calculated for each panel tested. Failure load and failure type for each test are reported. Finally, a finite-element model of a full-size panel was created for one of the deck types in order to capture the effects of internal damages. Analysis results of the finite-element model are compared against experimental results."],"dc:format":["application/pdf","p.201","12.64 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1042051817"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Civil","fiber reinforced polymers","bridge decks","load testing","finite element model","thermal expansion"],"dc:title":["ENVIRONMENTAL CONDITIONING AND TESTING OF THREE FIBER REINFORCED POLYMER PANELS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:36:45Z"}