{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1085590907"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1085590907","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"ASSESSING THE ENVIRONMENTAL AND BIOLOGICAL IMPLICATIONS OF VARIOUS ELEMENTS THROUGH ELEMENTAL SPECIATION USING INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY","abstract":"Elements rarely exist as free elements or ions instead they occur as a part of a compound or a species. Toxicological and beneficial effects in the medical and biological field can’t be attributed solely to an element, but to elemental compounds with different biological, physical and chemical properties. Therefore, it is pertinent not to rely on information, which is based solely on total elemental concentration and can be misleading. While there are many separation mechanisms used with inductively coupled plasma mass spectrometry (ICP-MS) for speciation, high performance liquid chromatography (HPLC) was the mode of separation utilized in this work. The coupling of HPLC and ICP-MS is a straightforward technique that allows for the speciation of elements in complex matrices, which may not otherwise be possible. The hybrid of the two techniques provide a robust, sensitive, and selective approach. The bottleneck of speciation analysis often lies at the sample preparation step, the goal being the preservation of species integrity. Improper or incomplete sample preparation can yield misleading results, because of the low tolerance of the ICP-MS for dissolved solids. For this study microwave assisted extraction was one of the techniques used to address this problem. The analyte of choice can be successfully extracted from its matrix with the proper optimization of the microwave parameters, and careful solvent selection. The use of inductively coupled plasma mass spectrometry to study the biological implications of various elements was studied. It was evaluated as a tool for elemental speciation as well as a prescreening tool for the study of larger biomolecules. This was achieved by coupling high performance liquid chromatography (HPLC), and using either the reversed – phase (RP), ion-exchange (IE), or size-exclusion mode (SEC) of separation. More specifically these techniques were used to investigate: the presence of selenium in plants, the distribution of several elements in dietary supplements, the residual occurrence of arsenic compounds in poultry samples, and the incorporation of selenium in selenium-enriched soybeans.","abstract_html":"Elements rarely exist as free elements or ions instead they occur as a part of a compound or a species. Toxicological and beneficial effects in the medical and biological field can’t be attributed solely to an element, but to elemental compounds with different biological, physical and chemical properties. Therefore, it is pertinent not to rely on information, which is based solely on total elemental concentration and can be misleading. While there are many separation mechanisms used with inductively coupled plasma mass spectrometry (ICP-MS) for speciation, high performance liquid chromatography (HPLC) was the mode of separation utilized in this work. The coupling of HPLC and ICP-MS is a straightforward technique that allows for the speciation of elements in complex matrices, which may not otherwise be possible. The hybrid of the two techniques provide a robust, sensitive, and selective approach. The bottleneck of speciation analysis often lies at the sample preparation step, the goal being the preservation of species integrity. Improper or incomplete sample preparation can yield misleading results, because of the low tolerance of the ICP-MS for dissolved solids. For this study microwave assisted extraction was one of the techniques used to address this problem. The analyte of choice can be successfully extracted from its matrix with the proper optimization of the microwave parameters, and careful solvent selection. The use of inductively coupled plasma mass spectrometry to study the biological implications of various elements was studied. It was evaluated as a tool for elemental speciation as well as a prescreening tool for the study of larger biomolecules. This was achieved by coupling high performance liquid chromatography (HPLC), and using either the reversed – phase (RP), ion-exchange (IE), or size-exclusion mode (SEC) of separation. More specifically these techniques were used to investigate: the presence of selenium in plants, the distribution of several elements in dietary supplements, the residual occurrence of arsenic compounds in poultry samples, and the incorporation of selenium in selenium-enriched soybeans.","abstract_has_math":false,"creators":["GRANT, TYRE D."],"institution":"University of Cincinnati","degree_name":"PhD","degree_level":"doctoral","degree_discipline":"Arts and Sciences : Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":["Caruso, Dr. Joseph"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-10-07","date_published":"2004-10-07","updated_at":"2026-11-27T04:36:52Z","subjects":["Chemistry, Analytical","Elemental Speciation","ICP-MS","Trace Elemental Analysis"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085590907","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085590907","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1085590907","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1085590907","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Caruso, Dr. Joseph"]},{"key":"dc:creator","label":"Author","values":["GRANT, TYRE D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004-10-07"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Arts and Sciences : Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry, Analytical","Elemental Speciation","ICP-MS","Trace Elemental Analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085590907"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Elements rarely exist as free elements or ions instead they occur as a part of a compound or a species. Toxicological and beneficial effects in the medical and biological field can’t be attributed solely to an element, but to elemental compounds with different biological, physical and chemical properties. Therefore, it is pertinent not to rely on information, which is based solely on total elemental concentration and can be misleading. While there are many separation mechanisms used with inductively coupled plasma mass spectrometry (ICP-MS) for speciation, high performance liquid chromatography (HPLC) was the mode of separation utilized in this work. The coupling of HPLC and ICP-MS is a straightforward technique that allows for the speciation of elements in complex matrices, which may not otherwise be possible. The hybrid of the two techniques provide a robust, sensitive, and selective approach. The bottleneck of speciation analysis often lies at the sample preparation step, the goal being the preservation of species integrity. Improper or incomplete sample preparation can yield misleading results, because of the low tolerance of the ICP-MS for dissolved solids. For this study microwave assisted extraction was one of the techniques used to address this problem. The analyte of choice can be successfully extracted from its matrix with the proper optimization of the microwave parameters, and careful solvent selection. The use of inductively coupled plasma mass spectrometry to study the biological implications of various elements was studied. It was evaluated as a tool for elemental speciation as well as a prescreening tool for the study of larger biomolecules. This was achieved by coupling high performance liquid chromatography (HPLC), and using either the reversed – phase (RP), ion-exchange (IE), or size-exclusion mode (SEC) of separation. More specifically these techniques were used to investigate: the presence of selenium in plants, the distribution of several elements in dietary supplements, the residual occurrence of arsenic compounds in poultry samples, and the incorporation of selenium in selenium-enriched soybeans."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.118","1.37 MB"]},{"key":"dc:title","label":"Title","values":["ASSESSING THE ENVIRONMENTAL AND BIOLOGICAL IMPLICATIONS OF VARIOUS ELEMENTS THROUGH ELEMENTAL SPECIATION USING INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY"]}]}],"canonical_facts":{"dc:contributor.advisor":["Caruso, Dr. Joseph"],"dc:creator":["GRANT, TYRE D."],"dc:date":["2004-10-07"],"dc:description":["Elements rarely exist as free elements or ions instead they occur as a part of a compound or a species. Toxicological and beneficial effects in the medical and biological field can’t be attributed solely to an element, but to elemental compounds with different biological, physical and chemical properties. Therefore, it is pertinent not to rely on information, which is based solely on total elemental concentration and can be misleading. While there are many separation mechanisms used with inductively coupled plasma mass spectrometry (ICP-MS) for speciation, high performance liquid chromatography (HPLC) was the mode of separation utilized in this work. The coupling of HPLC and ICP-MS is a straightforward technique that allows for the speciation of elements in complex matrices, which may not otherwise be possible. The hybrid of the two techniques provide a robust, sensitive, and selective approach. The bottleneck of speciation analysis often lies at the sample preparation step, the goal being the preservation of species integrity. Improper or incomplete sample preparation can yield misleading results, because of the low tolerance of the ICP-MS for dissolved solids. For this study microwave assisted extraction was one of the techniques used to address this problem. The analyte of choice can be successfully extracted from its matrix with the proper optimization of the microwave parameters, and careful solvent selection. The use of inductively coupled plasma mass spectrometry to study the biological implications of various elements was studied. It was evaluated as a tool for elemental speciation as well as a prescreening tool for the study of larger biomolecules. This was achieved by coupling high performance liquid chromatography (HPLC), and using either the reversed – phase (RP), ion-exchange (IE), or size-exclusion mode (SEC) of separation. More specifically these techniques were used to investigate: the presence of selenium in plants, the distribution of several elements in dietary supplements, the residual occurrence of arsenic compounds in poultry samples, and the incorporation of selenium in selenium-enriched soybeans."],"dc:format":["application/pdf","p.118","1.37 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085590907"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Chemistry, Analytical","Elemental Speciation","ICP-MS","Trace Elemental Analysis"],"dc:title":["ASSESSING THE ENVIRONMENTAL AND BIOLOGICAL IMPLICATIONS OF VARIOUS ELEMENTS THROUGH ELEMENTAL SPECIATION USING INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Arts and Sciences : Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["PhD"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:36:52Z"}