{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1085759166"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1085759166","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A BIOPARTICLE SEPARATION TECHNIQUE THROUGH MICROCHANNELS USING SEQUENTIAL PRESSURE PULSES","abstract":"In this work, an on-chip magnetic bead separator in an aqueous solution has been implemented on a plastic substrate. The technique has been successfully characterized in separating magnetic microspheres of 4.1 µm diameter from a suspension solution in DI water. µTAS (Micro Total Analysis System) frequently need to deal with bioparticle suspensions in solution. Separation of certain bioparticles is often desirable. Traditionally, methods like physical filtration have been used to separate biomolecules from suspension solutions. These methods, though well-established are not suited for integration on to mass-fabricated plastic lab-on-a-chip devices. The method developed in this work relies on the differential force exerted by application of high amplitude, short duration pressure pulses on a suspension solution, resulting in separation of suspended particles. From a dispensed volume of 500 nl of the suspension solution, up to 300 nl, or 60 % of volume has been cleared of particles.","abstract_html":"In this work, an on-chip magnetic bead separator in an aqueous solution has been implemented on a plastic substrate. The technique has been successfully characterized in separating magnetic microspheres of 4.1 µm diameter from a suspension solution in DI water. µTAS (Micro Total Analysis System) frequently need to deal with bioparticle suspensions in solution. Separation of certain bioparticles is often desirable. Traditionally, methods like physical filtration have been used to separate biomolecules from suspension solutions. These methods, though well-established are not suited for integration on to mass-fabricated plastic lab-on-a-chip devices. The method developed in this work relies on the differential force exerted by application of high amplitude, short duration pressure pulses on a suspension solution, resulting in separation of suspended particles. From a dispensed volume of 500 nl of the suspension solution, up to 300 nl, or 60 % of volume has been cleared of particles.","abstract_has_math":false,"creators":["JAIN, ALOK"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Ahn, Dr. Chong"],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-07-02","date_published":"2004-07-02","updated_at":"2026-11-27T04:36:52Z","subjects":["Bioparticle separation","magnetic bead separation","blood separation","pressure pulses","biomems"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085759166","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085759166","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1085759166","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1085759166","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahn, Dr. Chong"]},{"key":"dc:creator","label":"Author","values":["JAIN, ALOK"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2004-07-02"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bioparticle separation","magnetic bead separation","blood separation","pressure pulses","biomems"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085759166"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this work, an on-chip magnetic bead separator in an aqueous solution has been implemented on a plastic substrate. The technique has been successfully characterized in separating magnetic microspheres of 4.1 µm diameter from a suspension solution in DI water. µTAS (Micro Total Analysis System) frequently need to deal with bioparticle suspensions in solution. Separation of certain bioparticles is often desirable. Traditionally, methods like physical filtration have been used to separate biomolecules from suspension solutions. These methods, though well-established are not suited for integration on to mass-fabricated plastic lab-on-a-chip devices. The method developed in this work relies on the differential force exerted by application of high amplitude, short duration pressure pulses on a suspension solution, resulting in separation of suspended particles. From a dispensed volume of 500 nl of the suspension solution, up to 300 nl, or 60 % of volume has been cleared of particles."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.50","917.3 KB"]},{"key":"dc:title","label":"Title","values":["A BIOPARTICLE SEPARATION TECHNIQUE THROUGH MICROCHANNELS USING SEQUENTIAL PRESSURE PULSES"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ahn, Dr. Chong"],"dc:creator":["JAIN, ALOK"],"dc:date":["2004-07-02"],"dc:description":["In this work, an on-chip magnetic bead separator in an aqueous solution has been implemented on a plastic substrate. The technique has been successfully characterized in separating magnetic microspheres of 4.1 µm diameter from a suspension solution in DI water. µTAS (Micro Total Analysis System) frequently need to deal with bioparticle suspensions in solution. Separation of certain bioparticles is often desirable. Traditionally, methods like physical filtration have been used to separate biomolecules from suspension solutions. These methods, though well-established are not suited for integration on to mass-fabricated plastic lab-on-a-chip devices. The method developed in this work relies on the differential force exerted by application of high amplitude, short duration pressure pulses on a suspension solution, resulting in separation of suspended particles. From a dispensed volume of 500 nl of the suspension solution, up to 300 nl, or 60 % of volume has been cleared of particles."],"dc:format":["application/pdf","p.50","917.3 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1085759166"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Bioparticle separation","magnetic bead separation","blood separation","pressure pulses","biomems"],"dc:title":["A BIOPARTICLE SEPARATION TECHNIQUE THROUGH MICROCHANNELS USING SEQUENTIAL PRESSURE PULSES"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:36:52Z"}