{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1121436799"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1121436799","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Influence of Laser Parameters on Selective Retinal Photocoagulation for Macular Diseases","abstract":"Selective retinal photocoagulation uses short pulsed lasers to coagulate retinal pigment epithelium selectively, while sparing the photoreceptors. The problem associated with the usage of short pulsed laser is the difficulty in determining the correct dosimetry parameters. This study quantifies the influence of laser parameters and variation of thickness and melanin concentration of RPE over the therapeutic range. The laser-tissue interaction is numerically investigated by analyzing the transient temperature in ocular tissues during the treatment. The rate process analysis for thermal injury is employed to estimate the selective damage of retina. Calculated contours of Arrhenius integral show both the area and magnitude of damage caused by various laser parameters. Results reveal that the 2 micro-s pulsed-laser with green wavelength and Gaussian profile is more effective for selective retinal treatment. The repetition frequency of 100 Hz selectively damages RPE, while 1000 Hz produces damage to neural retina and choroid located within 2 micro-m from RPE interface. However, the maximum Arrhenius integral for 1000 Hz is ~2000 times greater than that for 100 Hz. The threshold energy required for 14 micro-m thick RPE is ~25% less than that for 10 micro-m RPE, while 6 micro-m RPE requires ~35% more energy.","abstract_html":"Selective retinal photocoagulation uses short pulsed lasers to coagulate retinal pigment epithelium selectively, while sparing the photoreceptors. The problem associated with the usage of short pulsed laser is the difficulty in determining the correct dosimetry parameters. This study quantifies the influence of laser parameters and variation of thickness and melanin concentration of RPE over the therapeutic range. The laser-tissue interaction is numerically investigated by analyzing the transient temperature in ocular tissues during the treatment. The rate process analysis for thermal injury is employed to estimate the selective damage of retina. Calculated contours of Arrhenius integral show both the area and magnitude of damage caused by various laser parameters. Results reveal that the 2 micro-s pulsed-laser with green wavelength and Gaussian profile is more effective for selective retinal treatment. The repetition frequency of 100 Hz selectively damages RPE, while 1000 Hz produces damage to neural retina and choroid located within 2 micro-m from RPE interface. However, the maximum Arrhenius integral for 1000 Hz is ~2000 times greater than that for 100 Hz. The threshold energy required for 14 micro-m thick RPE is ~25% less than that for 10 micro-m RPE, while 6 micro-m RPE requires ~35% more energy.","abstract_has_math":false,"creators":["Gopalakrishnan, Pradeep"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Banerjee, Dr. Rupak"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-09-27","date_published":"2005-09-27","updated_at":"2026-11-27T04:37:03Z","subjects":["laser photocoagulation","microphotocoagulation","selective retinal treatment","rate process analysis","retinal pigment epithelium"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1121436799","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1121436799","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1121436799","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1121436799","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Banerjee, Dr. Rupak"]},{"key":"dc:creator","label":"Author","values":["Gopalakrishnan, Pradeep"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-09-27"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["laser photocoagulation","microphotocoagulation","selective retinal treatment","rate process analysis","retinal pigment epithelium"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1121436799"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Selective retinal photocoagulation uses short pulsed lasers to coagulate retinal pigment epithelium selectively, while sparing the photoreceptors. The problem associated with the usage of short pulsed laser is the difficulty in determining the correct dosimetry parameters. This study quantifies the influence of laser parameters and variation of thickness and melanin concentration of RPE over the therapeutic range. The laser-tissue interaction is numerically investigated by analyzing the transient temperature in ocular tissues during the treatment. The rate process analysis for thermal injury is employed to estimate the selective damage of retina. Calculated contours of Arrhenius integral show both the area and magnitude of damage caused by various laser parameters. Results reveal that the 2 micro-s pulsed-laser with green wavelength and Gaussian profile is more effective for selective retinal treatment. The repetition frequency of 100 Hz selectively damages RPE, while 1000 Hz produces damage to neural retina and choroid located within 2 micro-m from RPE interface. However, the maximum Arrhenius integral for 1000 Hz is ~2000 times greater than that for 100 Hz. The threshold energy required for 14 micro-m thick RPE is ~25% less than that for 10 micro-m RPE, while 6 micro-m RPE requires ~35% more energy."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.61","1.67 MB"]},{"key":"dc:title","label":"Title","values":["Influence of Laser Parameters on Selective Retinal Photocoagulation for Macular Diseases"]}]}],"canonical_facts":{"dc:contributor.advisor":["Banerjee, Dr. Rupak"],"dc:creator":["Gopalakrishnan, Pradeep"],"dc:date":["2005-09-27"],"dc:description":["Selective retinal photocoagulation uses short pulsed lasers to coagulate retinal pigment epithelium selectively, while sparing the photoreceptors. The problem associated with the usage of short pulsed laser is the difficulty in determining the correct dosimetry parameters. This study quantifies the influence of laser parameters and variation of thickness and melanin concentration of RPE over the therapeutic range. The laser-tissue interaction is numerically investigated by analyzing the transient temperature in ocular tissues during the treatment. The rate process analysis for thermal injury is employed to estimate the selective damage of retina. Calculated contours of Arrhenius integral show both the area and magnitude of damage caused by various laser parameters. Results reveal that the 2 micro-s pulsed-laser with green wavelength and Gaussian profile is more effective for selective retinal treatment. The repetition frequency of 100 Hz selectively damages RPE, while 1000 Hz produces damage to neural retina and choroid located within 2 micro-m from RPE interface. However, the maximum Arrhenius integral for 1000 Hz is ~2000 times greater than that for 100 Hz. The threshold energy required for 14 micro-m thick RPE is ~25% less than that for 10 micro-m RPE, while 6 micro-m RPE requires ~35% more energy."],"dc:format":["application/pdf","p.61","1.67 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1121436799"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["laser photocoagulation","microphotocoagulation","selective retinal treatment","rate process analysis","retinal pigment epithelium"],"dc:title":["Influence of Laser Parameters on Selective Retinal Photocoagulation for Macular Diseases"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:37:03Z"}