{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1123783607"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1123783607","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"SILICON MICROELECTRODE ARRAYS FOR IN SITU ENVIRONMENTAL MONITORING","abstract":"Silicon microelectrode arrays for in situ environmental monitoring have been successfully developed in this work. Meniscus etching was used to sharpen these cantilevered probes. Microelectrodes with solid tips were fabricated for oxidation-reduction potential (ORP) measurements. Microelectrodes with recessed tips were fabricated for future developments of ion selective electrodes. Both microelectrode types were fully characterized with standard and reference solutions as recommended by the American Society for Testing and Materials (ASTM). The silicon microelectrodes have substantially smaller sensing areas (µm vs. cm) than their current commercial counterparts and exhibit significantly faster response times (milliseconds vs. minutes). Further, the sensors are robust due to redundant array configuration and the material strength of silicon. In the long term, we envision the use of these new sensors for field-based in situ monitoring in ground water quality and bioremediation applications.","abstract_html":"Silicon microelectrode arrays for in situ environmental monitoring have been successfully developed in this work. Meniscus etching was used to sharpen these cantilevered probes. Microelectrodes with solid tips were fabricated for oxidation-reduction potential (ORP) measurements. Microelectrodes with recessed tips were fabricated for future developments of ion selective electrodes. Both microelectrode types were fully characterized with standard and reference solutions as recommended by the American Society for Testing and Materials (ASTM). The silicon microelectrodes have substantially smaller sensing areas (µm vs. cm) than their current commercial counterparts and exhibit significantly faster response times (milliseconds vs. minutes). Further, the sensors are robust due to redundant array configuration and the material strength of silicon. In the long term, we envision the use of these new sensors for field-based in situ monitoring in ground water quality and bioremediation applications.","abstract_has_math":false,"creators":["WEI, XINGTAO"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Papautsky, Dr. Ian"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-09-27","date_published":"2005-09-27","updated_at":"2026-11-27T04:37:03Z","subjects":["Microelectrode Array Environmental Monitoring Silicon MEMS ORP Electrode"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123783607","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123783607","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1123783607","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1123783607","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Papautsky, Dr. Ian"]},{"key":"dc:creator","label":"Author","values":["WEI, XINGTAO"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-09-27"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microelectrode Array Environmental Monitoring Silicon MEMS ORP Electrode"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123783607"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Silicon microelectrode arrays for in situ environmental monitoring have been successfully developed in this work. Meniscus etching was used to sharpen these cantilevered probes. Microelectrodes with solid tips were fabricated for oxidation-reduction potential (ORP) measurements. Microelectrodes with recessed tips were fabricated for future developments of ion selective electrodes. Both microelectrode types were fully characterized with standard and reference solutions as recommended by the American Society for Testing and Materials (ASTM). The silicon microelectrodes have substantially smaller sensing areas (µm vs. cm) than their current commercial counterparts and exhibit significantly faster response times (milliseconds vs. minutes). Further, the sensors are robust due to redundant array configuration and the material strength of silicon. In the long term, we envision the use of these new sensors for field-based in situ monitoring in ground water quality and bioremediation applications."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.67","1.15 MB"]},{"key":"dc:title","label":"Title","values":["SILICON MICROELECTRODE ARRAYS FOR IN SITU ENVIRONMENTAL MONITORING"]}]}],"canonical_facts":{"dc:contributor.advisor":["Papautsky, Dr. Ian"],"dc:creator":["WEI, XINGTAO"],"dc:date":["2005-09-27"],"dc:description":["Silicon microelectrode arrays for in situ environmental monitoring have been successfully developed in this work. Meniscus etching was used to sharpen these cantilevered probes. Microelectrodes with solid tips were fabricated for oxidation-reduction potential (ORP) measurements. Microelectrodes with recessed tips were fabricated for future developments of ion selective electrodes. Both microelectrode types were fully characterized with standard and reference solutions as recommended by the American Society for Testing and Materials (ASTM). The silicon microelectrodes have substantially smaller sensing areas (µm vs. cm) than their current commercial counterparts and exhibit significantly faster response times (milliseconds vs. minutes). Further, the sensors are robust due to redundant array configuration and the material strength of silicon. In the long term, we envision the use of these new sensors for field-based in situ monitoring in ground water quality and bioremediation applications."],"dc:format":["application/pdf","p.67","1.15 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123783607"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Microelectrode Array Environmental Monitoring Silicon MEMS ORP Electrode"],"dc:title":["SILICON MICROELECTRODE ARRAYS FOR IN SITU ENVIRONMENTAL MONITORING"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:37:03Z"}