{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1123784883"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1123784883","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"THE DESIGN OF A UNIQUE AND ADAPTIVE UPPER LIMB PROSTHESIS","abstract":"The field of prosthetic development has existed since the first century. Ground breaking achievements have been made by great minds in the field, but in the last few decades, advancements in prosthetic development have slowed. Existing upper limb prosthetic devices are little more than basic tools to help the sound limb. Most terminal devices move at only two joints and are burdensome to the user due to high weight and poor weight distribution. This thesis presents new concepts in upper limb prosthetic design to improve multiple characteristics of upper limb prosthetics. In this design the terminal device and forearm are designed as a single system with motive means of the multi-articulated terminal device placed at the base of the forearm for better weight distribution. The system is capable of greater speeds, stronger grip, multiple prehension patterns, passive finger wrap all while reducing the burden upon the user of the device.","abstract_html":"The field of prosthetic development has existed since the first century. Ground breaking achievements have been made by great minds in the field, but in the last few decades, advancements in prosthetic development have slowed. Existing upper limb prosthetic devices are little more than basic tools to help the sound limb. Most terminal devices move at only two joints and are burdensome to the user due to high weight and poor weight distribution. This thesis presents new concepts in upper limb prosthetic design to improve multiple characteristics of upper limb prosthetics. In this design the terminal device and forearm are designed as a single system with motive means of the multi-articulated terminal device placed at the base of the forearm for better weight distribution. The system is capable of greater speeds, stronger grip, multiple prehension patterns, passive finger wrap all while reducing the burden upon the user of the device.","abstract_has_math":false,"creators":["JONES, DANIEL V."],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Huston, Dr. Ron"],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-09-27","date_published":"2005-09-27","updated_at":"2026-11-27T04:37:03Z","subjects":["Engineering, Mechanical","Prosthetic","Prosthesis","Upper Limb","Terminal Device","Articulated"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123784883","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123784883","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1123784883","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1123784883","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Huston, Dr. Ron"]},{"key":"dc:creator","label":"Author","values":["JONES, DANIEL V."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005-09-27"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Mechanical","Prosthetic","Prosthesis","Upper Limb","Terminal Device","Articulated"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123784883"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The field of prosthetic development has existed since the first century. Ground breaking achievements have been made by great minds in the field, but in the last few decades, advancements in prosthetic development have slowed. Existing upper limb prosthetic devices are little more than basic tools to help the sound limb. Most terminal devices move at only two joints and are burdensome to the user due to high weight and poor weight distribution. This thesis presents new concepts in upper limb prosthetic design to improve multiple characteristics of upper limb prosthetics. In this design the terminal device and forearm are designed as a single system with motive means of the multi-articulated terminal device placed at the base of the forearm for better weight distribution. The system is capable of greater speeds, stronger grip, multiple prehension patterns, passive finger wrap all while reducing the burden upon the user of the device."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.181","7.65 MB"]},{"key":"dc:title","label":"Title","values":["THE DESIGN OF A UNIQUE AND ADAPTIVE UPPER LIMB PROSTHESIS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Huston, Dr. Ron"],"dc:creator":["JONES, DANIEL V."],"dc:date":["2005-09-27"],"dc:description":["The field of prosthetic development has existed since the first century. Ground breaking achievements have been made by great minds in the field, but in the last few decades, advancements in prosthetic development have slowed. Existing upper limb prosthetic devices are little more than basic tools to help the sound limb. Most terminal devices move at only two joints and are burdensome to the user due to high weight and poor weight distribution. This thesis presents new concepts in upper limb prosthetic design to improve multiple characteristics of upper limb prosthetics. In this design the terminal device and forearm are designed as a single system with motive means of the multi-articulated terminal device placed at the base of the forearm for better weight distribution. The system is capable of greater speeds, stronger grip, multiple prehension patterns, passive finger wrap all while reducing the burden upon the user of the device."],"dc:format":["application/pdf","p.181","7.65 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1123784883"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Mechanical","Prosthetic","Prosthesis","Upper Limb","Terminal Device","Articulated"],"dc:title":["THE DESIGN OF A UNIQUE AND ADAPTIVE UPPER LIMB PROSTHESIS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:37:03Z"}