{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1237872813"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1237872813","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"State of Stress in Idealized Fusiform Abdominal Aortic Aneurysm Phantoms: A Photoelastic Study","abstract":"The absence of reliable predictors of rupture poses a significant challenge in the intervention and treatment of abdominal aortic aneurysm (AAA). Laplace’s law has been used to predict the risk of rupture based upon maximum diameter of the AAA(≥5cm); however, AAA with smaller diameters have been known to rupture, suggesting that more reliable predictors need to be determined. Current hypotheses point to the role of biaxial stress distributions on the aneurysm wall as a critical parameter in predicting the risk of rupture. Since, <i>in-vivo</i> direct measurement of stress and strain is not feasible, computational and <i>in-vitro</i> models have been utilized to study the stress or strain distributions in aneurysm models. In this study, the epoxy resin PL3 has been used to develop synthetic AAA phantoms for non-contact stress and strain analysis using the reflective photoelastic method. The PL3 resin has been previously used by Morris et al. (2004), but he did not address the material properties of the resin. The mechanical and optical properties of the PL3 epoxy resin have been characterized and an optimized resin to hardener ratio proposed, to render higher material flexibility without compromising the optical sensitivity for photoelastic analysis. The experimentally derived parameters have been validated against tests with known analytical solutions and the error associated with the photoelastic approach assessed. Stress separation of the photoelastic data using optical tracking methods has been explored and the benefits and drawbacks of the photoelastic approach discussed.","abstract_html":"The absence of reliable predictors of rupture poses a significant challenge in the intervention and treatment of abdominal aortic aneurysm (AAA). Laplace’s law has been used to predict the risk of rupture based upon maximum diameter of the AAA(≥5cm); however, AAA with smaller diameters have been known to rupture, suggesting that more reliable predictors need to be determined. Current hypotheses point to the role of biaxial stress distributions on the aneurysm wall as a critical parameter in predicting the risk of rupture. Since, &lt;i&gt;in-vivo&lt;/i&gt; direct measurement of stress and strain is not feasible, computational and &lt;i&gt;in-vitro&lt;/i&gt; models have been utilized to study the stress or strain distributions in aneurysm models. In this study, the epoxy resin PL3 has been used to develop synthetic AAA phantoms for non-contact stress and strain analysis using the reflective photoelastic method. The PL3 resin has been previously used by Morris et al. (2004), but he did not address the material properties of the resin. The mechanical and optical properties of the PL3 epoxy resin have been characterized and an optimized resin to hardener ratio proposed, to render higher material flexibility without compromising the optical sensitivity for photoelastic analysis. The experimentally derived parameters have been validated against tests with known analytical solutions and the error associated with the photoelastic approach assessed. Stress separation of the photoelastic data using optical tracking methods has been explored and the benefits and drawbacks of the photoelastic approach discussed.","abstract_has_math":false,"creators":["Srivastava, Gaurav K."],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Biomedical Engineering","degree_department":null,"school":null,"contributors":["Haridas, Balakrishna","Abot, Jandro","Abruzzo, Todd"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-26T04:28:22Z","subjects":["Biomedical Research","abdominal aortic aneurysms","photoelasticity"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1237872813","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1237872813","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1237872813","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1237872813","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Haridas, Balakrishna","Abot, Jandro","Abruzzo, Todd"]},{"key":"dc:creator","label":"Author","values":["Srivastava, Gaurav K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","abdominal aortic aneurysms","photoelasticity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1237872813"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The absence of reliable predictors of rupture poses a significant challenge in the intervention and treatment of abdominal aortic aneurysm (AAA). Laplace’s law has been used to predict the risk of rupture based upon maximum diameter of the AAA(≥5cm); however, AAA with smaller diameters have been known to rupture, suggesting that more reliable predictors need to be determined. Current hypotheses point to the role of biaxial stress distributions on the aneurysm wall as a critical parameter in predicting the risk of rupture. Since, <i>in-vivo</i> direct measurement of stress and strain is not feasible, computational and <i>in-vitro</i> models have been utilized to study the stress or strain distributions in aneurysm models. In this study, the epoxy resin PL3 has been used to develop synthetic AAA phantoms for non-contact stress and strain analysis using the reflective photoelastic method. The PL3 resin has been previously used by Morris et al. (2004), but he did not address the material properties of the resin. The mechanical and optical properties of the PL3 epoxy resin have been characterized and an optimized resin to hardener ratio proposed, to render higher material flexibility without compromising the optical sensitivity for photoelastic analysis. The experimentally derived parameters have been validated against tests with known analytical solutions and the error associated with the photoelastic approach assessed. Stress separation of the photoelastic data using optical tracking methods has been explored and the benefits and drawbacks of the photoelastic approach discussed."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.88","1.77 MB"]},{"key":"dc:title","label":"Title","values":["State of Stress in Idealized Fusiform Abdominal Aortic Aneurysm Phantoms: A Photoelastic Study"]}]}],"canonical_facts":{"dc:contributor":["Haridas, Balakrishna","Abot, Jandro","Abruzzo, Todd"],"dc:creator":["Srivastava, Gaurav K."],"dc:date":["2008"],"dc:description":["The absence of reliable predictors of rupture poses a significant challenge in the intervention and treatment of abdominal aortic aneurysm (AAA). Laplace’s law has been used to predict the risk of rupture based upon maximum diameter of the AAA(≥5cm); however, AAA with smaller diameters have been known to rupture, suggesting that more reliable predictors need to be determined. Current hypotheses point to the role of biaxial stress distributions on the aneurysm wall as a critical parameter in predicting the risk of rupture. Since, <i>in-vivo</i> direct measurement of stress and strain is not feasible, computational and <i>in-vitro</i> models have been utilized to study the stress or strain distributions in aneurysm models. In this study, the epoxy resin PL3 has been used to develop synthetic AAA phantoms for non-contact stress and strain analysis using the reflective photoelastic method. The PL3 resin has been previously used by Morris et al. (2004), but he did not address the material properties of the resin. The mechanical and optical properties of the PL3 epoxy resin have been characterized and an optimized resin to hardener ratio proposed, to render higher material flexibility without compromising the optical sensitivity for photoelastic analysis. The experimentally derived parameters have been validated against tests with known analytical solutions and the error associated with the photoelastic approach assessed. Stress separation of the photoelastic data using optical tracking methods has been explored and the benefits and drawbacks of the photoelastic approach discussed."],"dc:format":["application/pdf","p.88","1.77 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1237872813"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","abdominal aortic aneurysms","photoelasticity"],"dc:title":["State of Stress in Idealized Fusiform Abdominal Aortic Aneurysm Phantoms: A Photoelastic Study"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-26T04:28:22Z"}