{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1243354898"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1243354898","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Propofol as a bridge to extubation in the pediatric intensive care unit","abstract":"<p><b>Objective:</b> A significant number of children require long-term sedation and mechanical ventilation, which leads to significant morbidity and mortality. Propofol use decreases time to extubation and extubation failure in adults. However, there are safety concerns with long-term use of propofol, particularly in children. The purpose of this study is to report the safety and efficacy of propofol used as a bridge to extubation in children who have received long-term mechanical ventilation and sedation.</p><p><b>Methods:</b> After querying the pharmacy database, charts were reviewed to screen for propofol infusion use in pediatric and cardiac intensive care units at a single large children's hospital. A total of 152 uses of propofol (representing 141 unique patients) were analyzed in this case series. We measured exposure to propofol by total dose, average dose, maximum dose, and duration of propofol use. We assessed safety of propofol use in this limited setting by evaluating the incidence of bradycardia, hypotension, acidosis, and mortality. Efficacy is measured by time to extubation and extubation success.</p><p><b>Results:</b> Median time to extubation was 30 minutes and the extubation failure rate was 20%. Bradycardia (42%) and hypotension (28%) are common, but typically self-limited. Inotrope requirement prior to initiation of propofol predicted hypotension and acidosis. There were no cases of propofol infusion syndrome.</p><p><b>Conclusions:</b> The short-term use of propofol as a bridge to extubation in pediatric patients after longterm ventilation is a safe and effective strategy if used in carefully selected hemodynamically stable patients.</p>","abstract_html":"&lt;p&gt;&lt;b&gt;Objective:&lt;/b&gt; A significant number of children require long-term sedation and mechanical ventilation, which leads to significant morbidity and mortality. Propofol use decreases time to extubation and extubation failure in adults. However, there are safety concerns with long-term use of propofol, particularly in children. The purpose of this study is to report the safety and efficacy of propofol used as a bridge to extubation in children who have received long-term mechanical ventilation and sedation.&lt;/p&gt;&lt;p&gt;&lt;b&gt;Methods:&lt;/b&gt; After querying the pharmacy database, charts were reviewed to screen for propofol infusion use in pediatric and cardiac intensive care units at a single large children&#x27;s hospital. A total of 152 uses of propofol (representing 141 unique patients) were analyzed in this case series. We measured exposure to propofol by total dose, average dose, maximum dose, and duration of propofol use. We assessed safety of propofol use in this limited setting by evaluating the incidence of bradycardia, hypotension, acidosis, and mortality. Efficacy is measured by time to extubation and extubation success.&lt;/p&gt;&lt;p&gt;&lt;b&gt;Results:&lt;/b&gt; Median time to extubation was 30 minutes and the extubation failure rate was 20%. Bradycardia (42%) and hypotension (28%) are common, but typically self-limited. Inotrope requirement prior to initiation of propofol predicted hypotension and acidosis. There were no cases of propofol infusion syndrome.&lt;/p&gt;&lt;p&gt;&lt;b&gt;Conclusions:&lt;/b&gt; The short-term use of propofol as a bridge to extubation in pediatric patients after longterm ventilation is a safe and effective strategy if used in carefully selected hemodynamically stable patients.&lt;/p&gt;","abstract_has_math":false,"creators":["Mack, Elizabeth H."],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Medicine : Environmental Health","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Dietrich, Kim"],"committee_members":[],"year":2009,"date_issued":"2009-08-04","date_published":"2009-08-04","updated_at":"2026-11-27T04:37:33Z","subjects":["Health Care","Pharmaceuticals","Pharmacology","propofol","sedation","pediatric critical care","mechanical ventilation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1243354898","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1243354898","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1243354898","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1243354898","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Dietrich, Kim"]},{"key":"dc:creator","label":"Author","values":["Mack, Elizabeth H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-08-04"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medicine : Environmental Health"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health Care","Pharmaceuticals","Pharmacology","propofol","sedation","pediatric critical care","mechanical ventilation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1243354898"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p><b>Objective:</b> A significant number of children require long-term sedation and mechanical ventilation, which leads to significant morbidity and mortality. Propofol use decreases time to extubation and extubation failure in adults. However, there are safety concerns with long-term use of propofol, particularly in children. The purpose of this study is to report the safety and efficacy of propofol used as a bridge to extubation in children who have received long-term mechanical ventilation and sedation.</p><p><b>Methods:</b> After querying the pharmacy database, charts were reviewed to screen for propofol infusion use in pediatric and cardiac intensive care units at a single large children's hospital. A total of 152 uses of propofol (representing 141 unique patients) were analyzed in this case series. We measured exposure to propofol by total dose, average dose, maximum dose, and duration of propofol use. We assessed safety of propofol use in this limited setting by evaluating the incidence of bradycardia, hypotension, acidosis, and mortality. Efficacy is measured by time to extubation and extubation success.</p><p><b>Results:</b> Median time to extubation was 30 minutes and the extubation failure rate was 20%. Bradycardia (42%) and hypotension (28%) are common, but typically self-limited. Inotrope requirement prior to initiation of propofol predicted hypotension and acidosis. There were no cases of propofol infusion syndrome.</p><p><b>Conclusions:</b> The short-term use of propofol as a bridge to extubation in pediatric patients after longterm ventilation is a safe and effective strategy if used in carefully selected hemodynamically stable patients.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.17","437.6 KB"]},{"key":"dc:title","label":"Title","values":["Propofol as a bridge to extubation in the pediatric intensive care unit"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Dietrich, Kim"],"dc:creator":["Mack, Elizabeth H."],"dc:date":["2009-08-04"],"dc:description":["<p><b>Objective:</b> A significant number of children require long-term sedation and mechanical ventilation, which leads to significant morbidity and mortality. Propofol use decreases time to extubation and extubation failure in adults. However, there are safety concerns with long-term use of propofol, particularly in children. The purpose of this study is to report the safety and efficacy of propofol used as a bridge to extubation in children who have received long-term mechanical ventilation and sedation.</p><p><b>Methods:</b> After querying the pharmacy database, charts were reviewed to screen for propofol infusion use in pediatric and cardiac intensive care units at a single large children's hospital. A total of 152 uses of propofol (representing 141 unique patients) were analyzed in this case series. We measured exposure to propofol by total dose, average dose, maximum dose, and duration of propofol use. We assessed safety of propofol use in this limited setting by evaluating the incidence of bradycardia, hypotension, acidosis, and mortality. Efficacy is measured by time to extubation and extubation success.</p><p><b>Results:</b> Median time to extubation was 30 minutes and the extubation failure rate was 20%. Bradycardia (42%) and hypotension (28%) are common, but typically self-limited. Inotrope requirement prior to initiation of propofol predicted hypotension and acidosis. There were no cases of propofol infusion syndrome.</p><p><b>Conclusions:</b> The short-term use of propofol as a bridge to extubation in pediatric patients after longterm ventilation is a safe and effective strategy if used in carefully selected hemodynamically stable patients.</p>"],"dc:format":["application/pdf","p.17","437.6 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1243354898"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health Care","Pharmaceuticals","Pharmacology","propofol","sedation","pediatric critical care","mechanical ventilation"],"dc:title":["Propofol as a bridge to extubation in the pediatric intensive care unit"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Medicine : Environmental Health"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:37:33Z"}