{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1275924272"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1275924272","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Investigation and Improvement of Occupational and Military Noise Exposure Guidelines: Evaluation of Existing and Modified Noise Exposure Metrics Using Historical Animal Data","abstract":"Noise induced hearing loss is a significant problem in both the occupational and military settings. Current occupational noise guidelines use an energy based noise metric to predict the risk of hearing loss and thus ignore the effect of temporal characteristics of the noise. The practice is widely considered to underestimate the risk of a complex noise environment, where impulsive noises are embedded in a steady-state noise. A basic form for noise metrics is designed by combining the equivalent SPL and a temporal correction term defined as a function of kurtosis of the noise. Several noise metrics are developed by varying this basic form and evaluated utilizing existing chinchilla noise exposure data. It is shown that the kurtosis correction term significantly improves the correlation of the noise metric with the measured hearing losses in chinchillas. One of the investigated metrics, the kurtosis corrected A-weighted SPL, is applied to a human exposure study data as a preview of applying the metrics to human guidelines. A method to remove statistically unlikely outliers from the animal test data is also investigated. In addition to the basic temporal correction term for the characterization of complex noise exposures, a complex noise separation algorithm is explored to further characterize the exposure. In military noise settings, the effects of high intensity, impulsive noise on the auditory system are complex and difficult to quantify in a simple criterion. Several impulse noise criteria (e.g. MIL-STD 1474D, Pfander, Smoorenburg) are studied for their analytic structure to understand underlying basic assumptions. Then, these and other criteria are compared for their performance based on animal blast overpressure data. In occupational and military settings, a frequency-matched, weighted equivalent sound pressure level is investigated. The statistical correlations of this weight are compared with metrics currently in use. The possibility of developing a new noise standards according to the approach adopted in this study as well as remaining challenges are discussed.","abstract_html":"Noise induced hearing loss is a significant problem in both the occupational and military settings. Current occupational noise guidelines use an energy based noise metric to predict the risk of hearing loss and thus ignore the effect of temporal characteristics of the noise. The practice is widely considered to underestimate the risk of a complex noise environment, where impulsive noises are embedded in a steady-state noise. A basic form for noise metrics is designed by combining the equivalent SPL and a temporal correction term defined as a function of kurtosis of the noise. Several noise metrics are developed by varying this basic form and evaluated utilizing existing chinchilla noise exposure data. It is shown that the kurtosis correction term significantly improves the correlation of the noise metric with the measured hearing losses in chinchillas. One of the investigated metrics, the kurtosis corrected A-weighted SPL, is applied to a human exposure study data as a preview of applying the metrics to human guidelines. A method to remove statistically unlikely outliers from the animal test data is also investigated. In addition to the basic temporal correction term for the characterization of complex noise exposures, a complex noise separation algorithm is explored to further characterize the exposure. In military noise settings, the effects of high intensity, impulsive noise on the auditory system are complex and difficult to quantify in a simple criterion. Several impulse noise criteria (e.g. MIL-STD 1474D, Pfander, Smoorenburg) are studied for their analytic structure to understand underlying basic assumptions. Then, these and other criteria are compared for their performance based on animal blast overpressure data. In occupational and military settings, a frequency-matched, weighted equivalent sound pressure level is investigated. The statistical correlations of this weight are compared with metrics currently in use. The possibility of developing a new noise standards according to the approach adopted in this study as well as remaining challenges are discussed.","abstract_has_math":false,"creators":["Goley, George"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kim, J."],"committee_members":[],"year":2010,"date_issued":"2010-08-03","date_published":"2010-08-03","updated_at":"2026-11-27T04:37:33Z","subjects":["Mechanical Engineering","NIHL","hearing loss","impulsive noise","noise exposure","occupational noise","military noise"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1275924272","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1275924272","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1275924272","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1275924272","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Kim, J."]},{"key":"dc:creator","label":"Author","values":["Goley, George"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-08-03"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","NIHL","hearing loss","impulsive noise","noise exposure","occupational noise","military noise"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1275924272"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Noise induced hearing loss is a significant problem in both the occupational and military settings. Current occupational noise guidelines use an energy based noise metric to predict the risk of hearing loss and thus ignore the effect of temporal characteristics of the noise. The practice is widely considered to underestimate the risk of a complex noise environment, where impulsive noises are embedded in a steady-state noise. A basic form for noise metrics is designed by combining the equivalent SPL and a temporal correction term defined as a function of kurtosis of the noise. Several noise metrics are developed by varying this basic form and evaluated utilizing existing chinchilla noise exposure data. It is shown that the kurtosis correction term significantly improves the correlation of the noise metric with the measured hearing losses in chinchillas. One of the investigated metrics, the kurtosis corrected A-weighted SPL, is applied to a human exposure study data as a preview of applying the metrics to human guidelines. A method to remove statistically unlikely outliers from the animal test data is also investigated. In addition to the basic temporal correction term for the characterization of complex noise exposures, a complex noise separation algorithm is explored to further characterize the exposure. In military noise settings, the effects of high intensity, impulsive noise on the auditory system are complex and difficult to quantify in a simple criterion. Several impulse noise criteria (e.g. MIL-STD 1474D, Pfander, Smoorenburg) are studied for their analytic structure to understand underlying basic assumptions. Then, these and other criteria are compared for their performance based on animal blast overpressure data. In occupational and military settings, a frequency-matched, weighted equivalent sound pressure level is investigated. The statistical correlations of this weight are compared with metrics currently in use. The possibility of developing a new noise standards according to the approach adopted in this study as well as remaining challenges are discussed."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.104","2.29 MB"]},{"key":"dc:title","label":"Title","values":["Investigation and Improvement of Occupational and Military Noise Exposure Guidelines: Evaluation of Existing and Modified Noise Exposure Metrics Using Historical Animal Data"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Kim, J."],"dc:creator":["Goley, George"],"dc:date":["2010-08-03"],"dc:description":["Noise induced hearing loss is a significant problem in both the occupational and military settings. Current occupational noise guidelines use an energy based noise metric to predict the risk of hearing loss and thus ignore the effect of temporal characteristics of the noise. The practice is widely considered to underestimate the risk of a complex noise environment, where impulsive noises are embedded in a steady-state noise. A basic form for noise metrics is designed by combining the equivalent SPL and a temporal correction term defined as a function of kurtosis of the noise. Several noise metrics are developed by varying this basic form and evaluated utilizing existing chinchilla noise exposure data. It is shown that the kurtosis correction term significantly improves the correlation of the noise metric with the measured hearing losses in chinchillas. One of the investigated metrics, the kurtosis corrected A-weighted SPL, is applied to a human exposure study data as a preview of applying the metrics to human guidelines. A method to remove statistically unlikely outliers from the animal test data is also investigated. In addition to the basic temporal correction term for the characterization of complex noise exposures, a complex noise separation algorithm is explored to further characterize the exposure. In military noise settings, the effects of high intensity, impulsive noise on the auditory system are complex and difficult to quantify in a simple criterion. Several impulse noise criteria (e.g. MIL-STD 1474D, Pfander, Smoorenburg) are studied for their analytic structure to understand underlying basic assumptions. Then, these and other criteria are compared for their performance based on animal blast overpressure data. In occupational and military settings, a frequency-matched, weighted equivalent sound pressure level is investigated. The statistical correlations of this weight are compared with metrics currently in use. The possibility of developing a new noise standards according to the approach adopted in this study as well as remaining challenges are discussed."],"dc:format":["application/pdf","p.104","2.29 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1275924272"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Mechanical Engineering","NIHL","hearing loss","impulsive noise","noise exposure","occupational noise","military noise"],"dc:title":["Investigation and Improvement of Occupational and Military Noise Exposure Guidelines: Evaluation of Existing and Modified Noise Exposure Metrics Using Historical Animal Data"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:37:33Z"}