{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1282331536"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1282331536","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Novel Electrowetting Microvalve","abstract":"<p>Microvalves are essential devices in handling of microfluidic flows for applications in micro total analysis systems (μTAS). With the advancement of microfluidics and the development towards analysis chips there is a growing need for on-chip actuation methods to control liquid flows. However, lack of robustness, complex fabrication and high power consumption place challenges on conventional approaches.</p><p>Presented here is a novel microvalve based on electrowetting droplet actuation. Electrowetting is voltage manipulation of wetting of polar liquids on a dielectric surface. It has demonstrated robust beam steering, lenses, displays and lab-on-a-chip devices with simple and scalable fabrication techniques. In this thesis an electrowetting droplet actuation principle is described in detail. Two generations of electrowetting microvalves have been developed. Comparisons including structure design, working performance and operating voltages are performed to optimize the device performance. Furthermore, future work on SU-8 thin dielectrics for low voltage operation, device flexibility, air bubble removal, and no-leakage sealing are also discussed. The achieved results clearly show that the novel electrowetting microvalve presented here could be a good choice for future low cost, low power consumption, fast response, robust and flexible microvalves.</p>","abstract_html":"&lt;p&gt;Microvalves are essential devices in handling of microfluidic flows for applications in micro total analysis systems (μTAS). With the advancement of microfluidics and the development towards analysis chips there is a growing need for on-chip actuation methods to control liquid flows. However, lack of robustness, complex fabrication and high power consumption place challenges on conventional approaches.&lt;/p&gt;&lt;p&gt;Presented here is a novel microvalve based on electrowetting droplet actuation. Electrowetting is voltage manipulation of wetting of polar liquids on a dielectric surface. It has demonstrated robust beam steering, lenses, displays and lab-on-a-chip devices with simple and scalable fabrication techniques. In this thesis an electrowetting droplet actuation principle is described in detail. Two generations of electrowetting microvalves have been developed. Comparisons including structure design, working performance and operating voltages are performed to optimize the device performance. Furthermore, future work on SU-8 thin dielectrics for low voltage operation, device flexibility, air bubble removal, and no-leakage sealing are also discussed. The achieved results clearly show that the novel electrowetting microvalve presented here could be a good choice for future low cost, low power consumption, fast response, robust and flexible microvalves.&lt;/p&gt;","abstract_has_math":false,"creators":["Yang, Jia"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering and Applied Science: Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Heikenfeld, Jason"],"committee_members":[],"year":2010,"date_issued":"2010-12-06","date_published":"2010-12-06","updated_at":"2026-11-27T04:37:40Z","subjects":["Electrical Engineering","Electrowetting","Microvalve","droplet","Electrowetting Microvalve","Valve","SU-8","dielectric"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1282331536","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1282331536","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1282331536","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1282331536","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Heikenfeld, Jason"]},{"key":"dc:creator","label":"Author","values":["Yang, Jia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-12-06"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","Electrowetting","Microvalve","droplet","Electrowetting Microvalve","Valve","SU-8","dielectric"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1282331536"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Microvalves are essential devices in handling of microfluidic flows for applications in micro total analysis systems (μTAS). With the advancement of microfluidics and the development towards analysis chips there is a growing need for on-chip actuation methods to control liquid flows. However, lack of robustness, complex fabrication and high power consumption place challenges on conventional approaches.</p><p>Presented here is a novel microvalve based on electrowetting droplet actuation. Electrowetting is voltage manipulation of wetting of polar liquids on a dielectric surface. It has demonstrated robust beam steering, lenses, displays and lab-on-a-chip devices with simple and scalable fabrication techniques. In this thesis an electrowetting droplet actuation principle is described in detail. Two generations of electrowetting microvalves have been developed. Comparisons including structure design, working performance and operating voltages are performed to optimize the device performance. Furthermore, future work on SU-8 thin dielectrics for low voltage operation, device flexibility, air bubble removal, and no-leakage sealing are also discussed. The achieved results clearly show that the novel electrowetting microvalve presented here could be a good choice for future low cost, low power consumption, fast response, robust and flexible microvalves.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.47","1.53 MB"]},{"key":"dc:title","label":"Title","values":["Novel Electrowetting Microvalve"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Heikenfeld, Jason"],"dc:creator":["Yang, Jia"],"dc:date":["2010-12-06"],"dc:description":["<p>Microvalves are essential devices in handling of microfluidic flows for applications in micro total analysis systems (μTAS). With the advancement of microfluidics and the development towards analysis chips there is a growing need for on-chip actuation methods to control liquid flows. However, lack of robustness, complex fabrication and high power consumption place challenges on conventional approaches.</p><p>Presented here is a novel microvalve based on electrowetting droplet actuation. Electrowetting is voltage manipulation of wetting of polar liquids on a dielectric surface. It has demonstrated robust beam steering, lenses, displays and lab-on-a-chip devices with simple and scalable fabrication techniques. In this thesis an electrowetting droplet actuation principle is described in detail. Two generations of electrowetting microvalves have been developed. Comparisons including structure design, working performance and operating voltages are performed to optimize the device performance. Furthermore, future work on SU-8 thin dielectrics for low voltage operation, device flexibility, air bubble removal, and no-leakage sealing are also discussed. The achieved results clearly show that the novel electrowetting microvalve presented here could be a good choice for future low cost, low power consumption, fast response, robust and flexible microvalves.</p>"],"dc:format":["application/pdf","p.47","1.53 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1282331536"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Electrical Engineering","Electrowetting","Microvalve","droplet","Electrowetting Microvalve","Valve","SU-8","dielectric"],"dc:title":["Novel Electrowetting Microvalve"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:37:40Z"}