{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1291145722"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1291145722","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Investigation of Kinetics of Methotrexate for Therapeutic Treatment of Intraocular Lymphoma","abstract":"<p>Primary intraocular lymphoma (PIOL) is a term that refers to non-metastatic malignant lymphoid neoplasia that arises primarily within the eye. One of the currently available treatment options for PIOL is intravitreal injection of methotrexate. The main objective of this study is to numerically investigate the kinetics of methotrexate in a human eye following the standard induction–consolidation–maintenance (I-C-M) injection protocols for the treatment of PIOL (numerical study). In addition, we investigated the intravitreal concentration of methotrexate over time, and toxicity associated with slow sustained release of the drug from a biodegradable device containing methotrexate implanted in a deep scleral pocket of the eyes of normal rabbits (in vivo study).</p> <p> The 3-dimensional model of a rabbit eye was adapted from our previous studies and a human eye model was constructed based on its physiological dimensions. The retinal permeability values of methotrexate calculated for an albino rabbit and human eye were 1.1×10<sup>-5</sup> cm/s and 9.25×10<sup>-6</sup> cm/s, respectively. Given that the dosage above 0.1µM is considered tumoricidal, the cytotoxic levels of methotrexate were consistently achieved only in the induction phase and the concentration levels dropped below the cytotoxic levels for part of the consolidation and maintenance phases of the treatment following the I-C-M protocols. By making use of the results of this study, one could select a dosing interval for serial injections of methotrexate or establish a treatment schedule using controlled release methotrexate implant for the treatment of PIOL. </p> <p>For the <i>in vivo</i> study, biodegradable micro-needle implants (approximately 8 mg) loaded with 10% wt of methotrexate were fabricated using solvent cast method. The implants were all appropriately rigid at room temperature or when cooled in a refrigerator following fabrication. The micro-needles were expected to penetrate the inner scleral lamellae in the scleral pocket and the underlying uveal tissue of the ciliary body and project into the peripheral vitreous. All the implants were inserted surgically in a deep lamellar scleral pocket created in each eye of three albino New Zealand rabbits. Unfortunately, during the surgery unanticipated softening of the micro-needle implant occurred when the implant came in contact with the ocular tissues at body temperature. Consequently, the implant was not placed in the intended position but was simply placed in the intrascleral pocket. The micro-needle implants loaded with methotrexate did not perform mechanically in the intended way. </p> <p>The animals were sacrificed four weeks after the surgical implantation and the eyes were enucleated. The histopathology results showed that the softened implants (without and with the medication) placed in the intrascleral space (with none of its needles penetrating any eye wall structures) did not cause any obvious major toxicity to the eye. Since the micro-needles of the bio-degradable implant did not perform as expected because of the heat induced softening, our group is currently considering alternative implant designs and fabrication procedures which not only offer improved mechanical strength (rigidity) at higher temperatures but also allow us to place the implant directly in the vitreous via a full thickness eye wall microincision.</p>","abstract_html":"&lt;p&gt;Primary intraocular lymphoma (PIOL) is a term that refers to non-metastatic malignant lymphoid neoplasia that arises primarily within the eye. One of the currently available treatment options for PIOL is intravitreal injection of methotrexate. The main objective of this study is to numerically investigate the kinetics of methotrexate in a human eye following the standard induction–consolidation–maintenance (I-C-M) injection protocols for the treatment of PIOL (numerical study). In addition, we investigated the intravitreal concentration of methotrexate over time, and toxicity associated with slow sustained release of the drug from a biodegradable device containing methotrexate implanted in a deep scleral pocket of the eyes of normal rabbits (in vivo study).&lt;/p&gt; &lt;p&gt; The 3-dimensional model of a rabbit eye was adapted from our previous studies and a human eye model was constructed based on its physiological dimensions. The retinal permeability values of methotrexate calculated for an albino rabbit and human eye were 1.1×10&lt;sup&gt;-5&lt;/sup&gt; cm/s and 9.25×10&lt;sup&gt;-6&lt;/sup&gt; cm/s, respectively. Given that the dosage above 0.1µM is considered tumoricidal, the cytotoxic levels of methotrexate were consistently achieved only in the induction phase and the concentration levels dropped below the cytotoxic levels for part of the consolidation and maintenance phases of the treatment following the I-C-M protocols. By making use of the results of this study, one could select a dosing interval for serial injections of methotrexate or establish a treatment schedule using controlled release methotrexate implant for the treatment of PIOL. &lt;/p&gt; &lt;p&gt;For the &lt;i&gt;in vivo&lt;/i&gt; study, biodegradable micro-needle implants (approximately 8 mg) loaded with 10% wt of methotrexate were fabricated using solvent cast method. The implants were all appropriately rigid at room temperature or when cooled in a refrigerator following fabrication. The micro-needles were expected to penetrate the inner scleral lamellae in the scleral pocket and the underlying uveal tissue of the ciliary body and project into the peripheral vitreous. All the implants were inserted surgically in a deep lamellar scleral pocket created in each eye of three albino New Zealand rabbits. Unfortunately, during the surgery unanticipated softening of the micro-needle implant occurred when the implant came in contact with the ocular tissues at body temperature. Consequently, the implant was not placed in the intended position but was simply placed in the intrascleral pocket. The micro-needle implants loaded with methotrexate did not perform mechanically in the intended way. &lt;/p&gt; &lt;p&gt;The animals were sacrificed four weeks after the surgical implantation and the eyes were enucleated. The histopathology results showed that the softened implants (without and with the medication) placed in the intrascleral space (with none of its needles penetrating any eye wall structures) did not cause any obvious major toxicity to the eye. Since the micro-needles of the bio-degradable implant did not perform as expected because of the heat induced softening, our group is currently considering alternative implant designs and fabrication procedures which not only offer improved mechanical strength (rigidity) at higher temperatures but also allow us to place the implant directly in the vitreous via a full thickness eye wall microincision.&lt;/p&gt;","abstract_has_math":false,"creators":["Palakurthi, Nikhil Kumar"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering and Applied Science: Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Banerjee, Rupak"],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-27T04:37:40Z","subjects":["Mechanical Engineering","Intraocular Lymphoma","Methotrexate","Retinal Permeability","Drug Distribution","Intravitreal Injection","Intravitreal Implant"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1291145722","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1291145722","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1291145722","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1291145722","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Banerjee, Rupak"]},{"key":"dc:creator","label":"Author","values":["Palakurthi, Nikhil Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","Intraocular Lymphoma","Methotrexate","Retinal Permeability","Drug Distribution","Intravitreal Injection","Intravitreal Implant"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1291145722"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Primary intraocular lymphoma (PIOL) is a term that refers to non-metastatic malignant lymphoid neoplasia that arises primarily within the eye. One of the currently available treatment options for PIOL is intravitreal injection of methotrexate. The main objective of this study is to numerically investigate the kinetics of methotrexate in a human eye following the standard induction–consolidation–maintenance (I-C-M) injection protocols for the treatment of PIOL (numerical study). In addition, we investigated the intravitreal concentration of methotrexate over time, and toxicity associated with slow sustained release of the drug from a biodegradable device containing methotrexate implanted in a deep scleral pocket of the eyes of normal rabbits (in vivo study).</p> <p> The 3-dimensional model of a rabbit eye was adapted from our previous studies and a human eye model was constructed based on its physiological dimensions. The retinal permeability values of methotrexate calculated for an albino rabbit and human eye were 1.1×10<sup>-5</sup> cm/s and 9.25×10<sup>-6</sup> cm/s, respectively. Given that the dosage above 0.1µM is considered tumoricidal, the cytotoxic levels of methotrexate were consistently achieved only in the induction phase and the concentration levels dropped below the cytotoxic levels for part of the consolidation and maintenance phases of the treatment following the I-C-M protocols. By making use of the results of this study, one could select a dosing interval for serial injections of methotrexate or establish a treatment schedule using controlled release methotrexate implant for the treatment of PIOL. </p> <p>For the <i>in vivo</i> study, biodegradable micro-needle implants (approximately 8 mg) loaded with 10% wt of methotrexate were fabricated using solvent cast method. The implants were all appropriately rigid at room temperature or when cooled in a refrigerator following fabrication. The micro-needles were expected to penetrate the inner scleral lamellae in the scleral pocket and the underlying uveal tissue of the ciliary body and project into the peripheral vitreous. All the implants were inserted surgically in a deep lamellar scleral pocket created in each eye of three albino New Zealand rabbits. Unfortunately, during the surgery unanticipated softening of the micro-needle implant occurred when the implant came in contact with the ocular tissues at body temperature. Consequently, the implant was not placed in the intended position but was simply placed in the intrascleral pocket. The micro-needle implants loaded with methotrexate did not perform mechanically in the intended way. </p> <p>The animals were sacrificed four weeks after the surgical implantation and the eyes were enucleated. The histopathology results showed that the softened implants (without and with the medication) placed in the intrascleral space (with none of its needles penetrating any eye wall structures) did not cause any obvious major toxicity to the eye. Since the micro-needles of the bio-degradable implant did not perform as expected because of the heat induced softening, our group is currently considering alternative implant designs and fabrication procedures which not only offer improved mechanical strength (rigidity) at higher temperatures but also allow us to place the implant directly in the vitreous via a full thickness eye wall microincision.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.92","2.09 MB"]},{"key":"dc:title","label":"Title","values":["Investigation of Kinetics of Methotrexate for Therapeutic Treatment of Intraocular Lymphoma"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Banerjee, Rupak"],"dc:creator":["Palakurthi, Nikhil Kumar"],"dc:date":["2010"],"dc:description":["<p>Primary intraocular lymphoma (PIOL) is a term that refers to non-metastatic malignant lymphoid neoplasia that arises primarily within the eye. One of the currently available treatment options for PIOL is intravitreal injection of methotrexate. The main objective of this study is to numerically investigate the kinetics of methotrexate in a human eye following the standard induction–consolidation–maintenance (I-C-M) injection protocols for the treatment of PIOL (numerical study). In addition, we investigated the intravitreal concentration of methotrexate over time, and toxicity associated with slow sustained release of the drug from a biodegradable device containing methotrexate implanted in a deep scleral pocket of the eyes of normal rabbits (in vivo study).</p> <p> The 3-dimensional model of a rabbit eye was adapted from our previous studies and a human eye model was constructed based on its physiological dimensions. The retinal permeability values of methotrexate calculated for an albino rabbit and human eye were 1.1×10<sup>-5</sup> cm/s and 9.25×10<sup>-6</sup> cm/s, respectively. Given that the dosage above 0.1µM is considered tumoricidal, the cytotoxic levels of methotrexate were consistently achieved only in the induction phase and the concentration levels dropped below the cytotoxic levels for part of the consolidation and maintenance phases of the treatment following the I-C-M protocols. By making use of the results of this study, one could select a dosing interval for serial injections of methotrexate or establish a treatment schedule using controlled release methotrexate implant for the treatment of PIOL. </p> <p>For the <i>in vivo</i> study, biodegradable micro-needle implants (approximately 8 mg) loaded with 10% wt of methotrexate were fabricated using solvent cast method. The implants were all appropriately rigid at room temperature or when cooled in a refrigerator following fabrication. The micro-needles were expected to penetrate the inner scleral lamellae in the scleral pocket and the underlying uveal tissue of the ciliary body and project into the peripheral vitreous. All the implants were inserted surgically in a deep lamellar scleral pocket created in each eye of three albino New Zealand rabbits. Unfortunately, during the surgery unanticipated softening of the micro-needle implant occurred when the implant came in contact with the ocular tissues at body temperature. Consequently, the implant was not placed in the intended position but was simply placed in the intrascleral pocket. The micro-needle implants loaded with methotrexate did not perform mechanically in the intended way. </p> <p>The animals were sacrificed four weeks after the surgical implantation and the eyes were enucleated. The histopathology results showed that the softened implants (without and with the medication) placed in the intrascleral space (with none of its needles penetrating any eye wall structures) did not cause any obvious major toxicity to the eye. Since the micro-needles of the bio-degradable implant did not perform as expected because of the heat induced softening, our group is currently considering alternative implant designs and fabrication procedures which not only offer improved mechanical strength (rigidity) at higher temperatures but also allow us to place the implant directly in the vitreous via a full thickness eye wall microincision.</p>"],"dc:format":["application/pdf","p.92","2.09 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1291145722"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","Intraocular Lymphoma","Methotrexate","Retinal Permeability","Drug Distribution","Intravitreal Injection","Intravitreal Implant"],"dc:title":["Investigation of Kinetics of Methotrexate for Therapeutic Treatment of Intraocular Lymphoma"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:37:40Z"}