{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1342106902"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1342106902","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Precision measurement of the D*(2010)+ natural line width and D*(2010)+, D0 mass difference","abstract":"<p>I present the measurement of the natural line width of the D<sup>*+</sup> meson, Γ(D<sup>*+</sup>), in the transition D<sup>*+</sup> → D<sup>0</sup> ϖ<sup>+</sup> using 522.8 fb<sup>-1</sup> of data from the BaBar detector. The D<sup>0</sup> is reconstructed in two decay channels: D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup> and D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup>ϖ<sup>-</sup>ϖ<sup>+</sup>. We use Monte Carlo to simulate our reconstruction resolution in the difference of the reconstructed D<sup>*+</sup> and reconstructed D<sup>0</sup> masses. We fit a relativistic Breit-Wigner form convolved with the measured resolution function plus background to the mass difference distribution, allowing for an additional scale factor between simulated and real data. The dominant source of systematic uncertainty in the Δm measurements is currently overestimated and will be reduced in the publication of this analysis after further assessment. Results are reported in natural units (ℏ = c = 1).<br><br></p><p>Using the decay mode D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup> we find,<br>Γ = 83.4 ± 1.7 ± 1.4 keV<br>Δ m = m(D<sup>*+</sup>) - m(D<sup>0</sup>) = 145425.6 ± 0.6 ± 1.5 keV<br><br></p><p>Using the decay mode D0→ K-ϖ+ϖ-ϖ+ we find,<br>Γ = 83.2 ± 1.5 ± 2.9 keV<br>Δm = m(D<sup>*+</sup>) - m(D<sup>0</sup>) = 145426.6 ± 0.5 ± 1.9 keV<br><br></p><p>The combined measurement is<br><Γ> = 83.3 ± 1.3 ± 1.4 keV<br><Δm> = 145425.8 ± 0.5 ± 1.6 keV<br></p>","abstract_html":"&lt;p&gt;I present the measurement of the natural line width of the D&lt;sup&gt;*+&lt;/sup&gt; meson, Γ(D&lt;sup&gt;*+&lt;/sup&gt;), in the transition D&lt;sup&gt;*+&lt;/sup&gt; → D&lt;sup&gt;0&lt;/sup&gt; ϖ&lt;sup&gt;+&lt;/sup&gt; using 522.8 fb&lt;sup&gt;-1&lt;/sup&gt; of data from the BaBar detector. The D&lt;sup&gt;0&lt;/sup&gt; is reconstructed in two decay channels: D&lt;sup&gt;0&lt;/sup&gt; → K&lt;sup&gt;-&lt;/sup&gt;ϖ&lt;sup&gt;+&lt;/sup&gt; and D&lt;sup&gt;0&lt;/sup&gt; → K&lt;sup&gt;-&lt;/sup&gt;ϖ&lt;sup&gt;+&lt;/sup&gt;ϖ&lt;sup&gt;-&lt;/sup&gt;ϖ&lt;sup&gt;+&lt;/sup&gt;. We use Monte Carlo to simulate our reconstruction resolution in the difference of the reconstructed D&lt;sup&gt;*+&lt;/sup&gt; and reconstructed D&lt;sup&gt;0&lt;/sup&gt; masses. We fit a relativistic Breit-Wigner form convolved with the measured resolution function plus background to the mass difference distribution, allowing for an additional scale factor between simulated and real data. The dominant source of systematic uncertainty in the Δm measurements is currently overestimated and will be reduced in the publication of this analysis after further assessment. Results are reported in natural units (ℏ = c = 1).&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;Using the decay mode D&lt;sup&gt;0&lt;/sup&gt; → K&lt;sup&gt;-&lt;/sup&gt;ϖ&lt;sup&gt;+&lt;/sup&gt; we find,&lt;br&gt;Γ = 83.4 ± 1.7 ± 1.4 keV&lt;br&gt;Δ m = m(D&lt;sup&gt;*+&lt;/sup&gt;) - m(D&lt;sup&gt;0&lt;/sup&gt;) = 145425.6 ± 0.6 ± 1.5 keV&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;Using the decay mode D0→ K-ϖ+ϖ-ϖ+ we find,&lt;br&gt;Γ = 83.2 ± 1.5 ± 2.9 keV&lt;br&gt;Δm = m(D&lt;sup&gt;*+&lt;/sup&gt;) - m(D&lt;sup&gt;0&lt;/sup&gt;) = 145426.6 ± 0.5 ± 1.9 keV&lt;br&gt;&lt;br&gt;&lt;/p&gt;&lt;p&gt;The combined measurement is&lt;br&gt;&lt;Γ&gt; = 83.3 ± 1.3 ± 1.4 keV&lt;br&gt;&lt;Δm&gt; = 145425.8 ± 0.5 ± 1.6 keV&lt;br&gt;&lt;/p&gt;","abstract_has_math":false,"creators":["Huard, Zachary"],"institution":"University of Cincinnati","degree_name":"PhD","degree_level":"doctoral","degree_discipline":"Arts and Sciences: Physics","degree_department":null,"school":null,"contributors":["Meadows, Brian","Sokoloff, Michael"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-10-16","date_published":"2012-10-16","updated_at":"2026-11-26T04:30:36Z","subjects":["Physics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1342106902","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1342106902","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1342106902","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1342106902","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Meadows, Brian","Sokoloff, Michael"]},{"key":"dc:creator","label":"Author","values":["Huard, Zachary"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-10-16"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Arts and Sciences: Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1342106902"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>I present the measurement of the natural line width of the D<sup>*+</sup> meson, Γ(D<sup>*+</sup>), in the transition D<sup>*+</sup> → D<sup>0</sup> ϖ<sup>+</sup> using 522.8 fb<sup>-1</sup> of data from the BaBar detector. The D<sup>0</sup> is reconstructed in two decay channels: D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup> and D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup>ϖ<sup>-</sup>ϖ<sup>+</sup>. We use Monte Carlo to simulate our reconstruction resolution in the difference of the reconstructed D<sup>*+</sup> and reconstructed D<sup>0</sup> masses. We fit a relativistic Breit-Wigner form convolved with the measured resolution function plus background to the mass difference distribution, allowing for an additional scale factor between simulated and real data. The dominant source of systematic uncertainty in the Δm measurements is currently overestimated and will be reduced in the publication of this analysis after further assessment. Results are reported in natural units (ℏ = c = 1).<br><br></p><p>Using the decay mode D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup> we find,<br>Γ = 83.4 ± 1.7 ± 1.4 keV<br>Δ m = m(D<sup>*+</sup>) - m(D<sup>0</sup>) = 145425.6 ± 0.6 ± 1.5 keV<br><br></p><p>Using the decay mode D0→ K-ϖ+ϖ-ϖ+ we find,<br>Γ = 83.2 ± 1.5 ± 2.9 keV<br>Δm = m(D<sup>*+</sup>) - m(D<sup>0</sup>) = 145426.6 ± 0.5 ± 1.9 keV<br><br></p><p>The combined measurement is<br><Γ> = 83.3 ± 1.3 ± 1.4 keV<br><Δm> = 145425.8 ± 0.5 ± 1.6 keV<br></p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.131","2. MB"]},{"key":"dc:title","label":"Title","values":["Precision measurement of the D*(2010)+ natural line width and D*(2010)+, D0 mass difference"]}]}],"canonical_facts":{"dc:contributor":["Meadows, Brian","Sokoloff, Michael"],"dc:creator":["Huard, Zachary"],"dc:date":["2012-10-16"],"dc:description":["<p>I present the measurement of the natural line width of the D<sup>*+</sup> meson, Γ(D<sup>*+</sup>), in the transition D<sup>*+</sup> → D<sup>0</sup> ϖ<sup>+</sup> using 522.8 fb<sup>-1</sup> of data from the BaBar detector. The D<sup>0</sup> is reconstructed in two decay channels: D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup> and D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup>ϖ<sup>-</sup>ϖ<sup>+</sup>. We use Monte Carlo to simulate our reconstruction resolution in the difference of the reconstructed D<sup>*+</sup> and reconstructed D<sup>0</sup> masses. We fit a relativistic Breit-Wigner form convolved with the measured resolution function plus background to the mass difference distribution, allowing for an additional scale factor between simulated and real data. The dominant source of systematic uncertainty in the Δm measurements is currently overestimated and will be reduced in the publication of this analysis after further assessment. Results are reported in natural units (ℏ = c = 1).<br><br></p><p>Using the decay mode D<sup>0</sup> → K<sup>-</sup>ϖ<sup>+</sup> we find,<br>Γ = 83.4 ± 1.7 ± 1.4 keV<br>Δ m = m(D<sup>*+</sup>) - m(D<sup>0</sup>) = 145425.6 ± 0.6 ± 1.5 keV<br><br></p><p>Using the decay mode D0→ K-ϖ+ϖ-ϖ+ we find,<br>Γ = 83.2 ± 1.5 ± 2.9 keV<br>Δm = m(D<sup>*+</sup>) - m(D<sup>0</sup>) = 145426.6 ± 0.5 ± 1.9 keV<br><br></p><p>The combined measurement is<br><Γ> = 83.3 ± 1.3 ± 1.4 keV<br><Δm> = 145425.8 ± 0.5 ± 1.6 keV<br></p>"],"dc:format":["application/pdf","p.131","2. MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1342106902"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics"],"dc:title":["Precision measurement of the D*(2010)+ natural line width and D*(2010)+, D0 mass difference"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Arts and Sciences: Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["PhD"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-26T04:30:36Z"}