{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1367940889"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1367940889","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Case Study Analysis of Parameter Effects within the Nitrification and Denitrification Processes of Rendering Wastewater using Data Mining Techniques","abstract":"Rendering facilities utilize inedible animal and grease by-products in order to produce finished product mainly used in manufactured animal feeds, biofuels, and chemicals. In order to do so, raw material is subjected to multiple rendering processes. The resulting wastewater from rendering facilities is difficult to treat in conventional biological treatment systems due to variable inputs of high concentrations of biologically derived total inorganic ammonia and organic matter. Two high solids, high rate activated sludge processes, the Sequential Batch Reactor and Modified Ludzack-Ettinger, have been used for rendering facility wastewater treatment. Data from an example of each process were analyzed in this study. Microsoft Access databases and Microsoft Excel analysis tools were employed for data harboring and analysis. Four years (2009 to 2012) of available parameter data were collected from each facility, and both exploratory data analysis and trend analysis were conducted.The Sequential Batch Reactor facility experienced high inorganic nitrogen (total ammonia, nitrite, and nitrate) and organic matter concentrations within treated cycled wastewater effluent during 2009 and 2010. Facility operators and engineers speculated that high wastewater temperatures were responsible for treatment failure; design engineers did not agree. Temperatures met design criteria, and dissolved oxygen levels appeared adequate. However, a surface aerator was installed as a means of cooling the wastewater, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement during 2011 and 2012.The Modified Ludzack-Ettinger facility experienced high inorganic nitrogen and organic matter concentrations within treated cycled wastewater effluent during a catastrophic failure in 2010. In this case, facility operators and engineers speculated that low dissolved oxygen concentrations resulted in treatment failure. A surface aerator was installed in order to increase dissolved oxygen levels in the system, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement and overall success during 2011 and 2012.After review of the data, conclusions were made and compared to the original speculations of the cause of high inorganic nitrogen in treated effluents. It was concluded that high wastewater temperatures predominantly created upset conditions at the Sequential Batch Reactor facility, resulting in treatment failure. Due to these high wastewater temperatures, microbial inhibition and free ammonia toxicity more than likely contributed to the treatment failure. Due to lack of data, it was difficult to make definite conclusions at the Modified Ludzack-Ettinger facility. It appeared that high wastewater temperatures, once again, predominantly created conditions for treatment failure. Because wastewater temperatures appeared to be inhibitory at both facilities, data suggest an upper temperature threshold of 95°F should not be exceeded in high solids, high rate rendering wastewater treatment systems for successful treatment of rendering wastewater during summer months.","abstract_html":"Rendering facilities utilize inedible animal and grease by-products in order to produce finished product mainly used in manufactured animal feeds, biofuels, and chemicals. In order to do so, raw material is subjected to multiple rendering processes. The resulting wastewater from rendering facilities is difficult to treat in conventional biological treatment systems due to variable inputs of high concentrations of biologically derived total inorganic ammonia and organic matter. Two high solids, high rate activated sludge processes, the Sequential Batch Reactor and Modified Ludzack-Ettinger, have been used for rendering facility wastewater treatment. Data from an example of each process were analyzed in this study. Microsoft Access databases and Microsoft Excel analysis tools were employed for data harboring and analysis. Four years (2009 to 2012) of available parameter data were collected from each facility, and both exploratory data analysis and trend analysis were conducted.The Sequential Batch Reactor facility experienced high inorganic nitrogen (total ammonia, nitrite, and nitrate) and organic matter concentrations within treated cycled wastewater effluent during 2009 and 2010. Facility operators and engineers speculated that high wastewater temperatures were responsible for treatment failure; design engineers did not agree. Temperatures met design criteria, and dissolved oxygen levels appeared adequate. However, a surface aerator was installed as a means of cooling the wastewater, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement during 2011 and 2012.The Modified Ludzack-Ettinger facility experienced high inorganic nitrogen and organic matter concentrations within treated cycled wastewater effluent during a catastrophic failure in 2010. In this case, facility operators and engineers speculated that low dissolved oxygen concentrations resulted in treatment failure. A surface aerator was installed in order to increase dissolved oxygen levels in the system, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement and overall success during 2011 and 2012.After review of the data, conclusions were made and compared to the original speculations of the cause of high inorganic nitrogen in treated effluents. It was concluded that high wastewater temperatures predominantly created upset conditions at the Sequential Batch Reactor facility, resulting in treatment failure. Due to these high wastewater temperatures, microbial inhibition and free ammonia toxicity more than likely contributed to the treatment failure. Due to lack of data, it was difficult to make definite conclusions at the Modified Ludzack-Ettinger facility. It appeared that high wastewater temperatures, once again, predominantly created conditions for treatment failure. Because wastewater temperatures appeared to be inhibitory at both facilities, data suggest an upper temperature threshold of 95°F should not be exceeded in high solids, high rate rendering wastewater treatment systems for successful treatment of rendering wastewater during summer months.","abstract_has_math":false,"creators":["Elrod, Jon L., B.S."],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering and Applied Science: Environmental Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Kupferle, Margaret"],"committee_members":[],"year":2013,"date_issued":"2013-10-14","date_published":"2013-10-14","updated_at":"2026-11-27T04:12:47Z","subjects":["Environmental Science","Rendering Wastewater","Nitrification and Denitrification","Activated Sludge","High Temperatures","Sequential Batch Reactor","Modified Ludzack-Ettinger"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1367940889","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1367940889","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1367940889","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1367940889","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Kupferle, Margaret"]},{"key":"dc:creator","label":"Author","values":["Elrod, Jon L., B.S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-10-14"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Environmental Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Environmental Science","Rendering Wastewater","Nitrification and Denitrification","Activated Sludge","High Temperatures","Sequential Batch Reactor","Modified Ludzack-Ettinger"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1367940889"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Rendering facilities utilize inedible animal and grease by-products in order to produce finished product mainly used in manufactured animal feeds, biofuels, and chemicals. In order to do so, raw material is subjected to multiple rendering processes. The resulting wastewater from rendering facilities is difficult to treat in conventional biological treatment systems due to variable inputs of high concentrations of biologically derived total inorganic ammonia and organic matter. Two high solids, high rate activated sludge processes, the Sequential Batch Reactor and Modified Ludzack-Ettinger, have been used for rendering facility wastewater treatment. Data from an example of each process were analyzed in this study. Microsoft Access databases and Microsoft Excel analysis tools were employed for data harboring and analysis. Four years (2009 to 2012) of available parameter data were collected from each facility, and both exploratory data analysis and trend analysis were conducted.The Sequential Batch Reactor facility experienced high inorganic nitrogen (total ammonia, nitrite, and nitrate) and organic matter concentrations within treated cycled wastewater effluent during 2009 and 2010. Facility operators and engineers speculated that high wastewater temperatures were responsible for treatment failure; design engineers did not agree. Temperatures met design criteria, and dissolved oxygen levels appeared adequate. However, a surface aerator was installed as a means of cooling the wastewater, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement during 2011 and 2012.The Modified Ludzack-Ettinger facility experienced high inorganic nitrogen and organic matter concentrations within treated cycled wastewater effluent during a catastrophic failure in 2010. In this case, facility operators and engineers speculated that low dissolved oxygen concentrations resulted in treatment failure. A surface aerator was installed in order to increase dissolved oxygen levels in the system, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement and overall success during 2011 and 2012.After review of the data, conclusions were made and compared to the original speculations of the cause of high inorganic nitrogen in treated effluents. It was concluded that high wastewater temperatures predominantly created upset conditions at the Sequential Batch Reactor facility, resulting in treatment failure. Due to these high wastewater temperatures, microbial inhibition and free ammonia toxicity more than likely contributed to the treatment failure. Due to lack of data, it was difficult to make definite conclusions at the Modified Ludzack-Ettinger facility. It appeared that high wastewater temperatures, once again, predominantly created conditions for treatment failure. Because wastewater temperatures appeared to be inhibitory at both facilities, data suggest an upper temperature threshold of 95°F should not be exceeded in high solids, high rate rendering wastewater treatment systems for successful treatment of rendering wastewater during summer months."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.115","6.97 MB"]},{"key":"dc:title","label":"Title","values":["A Case Study Analysis of Parameter Effects within the Nitrification and Denitrification Processes of Rendering Wastewater using Data Mining Techniques"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Kupferle, Margaret"],"dc:creator":["Elrod, Jon L., B.S."],"dc:date":["2013-10-14"],"dc:description":["Rendering facilities utilize inedible animal and grease by-products in order to produce finished product mainly used in manufactured animal feeds, biofuels, and chemicals. In order to do so, raw material is subjected to multiple rendering processes. The resulting wastewater from rendering facilities is difficult to treat in conventional biological treatment systems due to variable inputs of high concentrations of biologically derived total inorganic ammonia and organic matter. Two high solids, high rate activated sludge processes, the Sequential Batch Reactor and Modified Ludzack-Ettinger, have been used for rendering facility wastewater treatment. Data from an example of each process were analyzed in this study. Microsoft Access databases and Microsoft Excel analysis tools were employed for data harboring and analysis. Four years (2009 to 2012) of available parameter data were collected from each facility, and both exploratory data analysis and trend analysis were conducted.The Sequential Batch Reactor facility experienced high inorganic nitrogen (total ammonia, nitrite, and nitrate) and organic matter concentrations within treated cycled wastewater effluent during 2009 and 2010. Facility operators and engineers speculated that high wastewater temperatures were responsible for treatment failure; design engineers did not agree. Temperatures met design criteria, and dissolved oxygen levels appeared adequate. However, a surface aerator was installed as a means of cooling the wastewater, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement during 2011 and 2012.The Modified Ludzack-Ettinger facility experienced high inorganic nitrogen and organic matter concentrations within treated cycled wastewater effluent during a catastrophic failure in 2010. In this case, facility operators and engineers speculated that low dissolved oxygen concentrations resulted in treatment failure. A surface aerator was installed in order to increase dissolved oxygen levels in the system, and the system reacquired the ability to successfully treat the wastewater. The facility subsequently experienced improvement and overall success during 2011 and 2012.After review of the data, conclusions were made and compared to the original speculations of the cause of high inorganic nitrogen in treated effluents. It was concluded that high wastewater temperatures predominantly created upset conditions at the Sequential Batch Reactor facility, resulting in treatment failure. Due to these high wastewater temperatures, microbial inhibition and free ammonia toxicity more than likely contributed to the treatment failure. Due to lack of data, it was difficult to make definite conclusions at the Modified Ludzack-Ettinger facility. It appeared that high wastewater temperatures, once again, predominantly created conditions for treatment failure. Because wastewater temperatures appeared to be inhibitory at both facilities, data suggest an upper temperature threshold of 95°F should not be exceeded in high solids, high rate rendering wastewater treatment systems for successful treatment of rendering wastewater during summer months."],"dc:format":["application/pdf","p.115","6.97 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1367940889"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Environmental Science","Rendering Wastewater","Nitrification and Denitrification","Activated Sludge","High Temperatures","Sequential Batch Reactor","Modified Ludzack-Ettinger"],"dc:title":["A Case Study Analysis of Parameter Effects within the Nitrification and Denitrification Processes of Rendering Wastewater using Data Mining Techniques"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Environmental Science"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:12:47Z"}