{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1396454864"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1396454864","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Evaluation of the Seismic Performance Factors for Hybrid Coupled Core Wall Systems with Steel Fuse Coupling Beams","abstract":"Coupled core wall systems with steel coupling beams are effective seismic force resisting systems to resist structural collapse. A typical coupling beam shear wall system would dissipate energy through the formation of plastic hinges at the coupling beam-wall interface. These plastic hinges would damage the coupling beam, requiring an infeasible and uneconomical repair involving the replacement of the beam embedded in the concrete wall pier. However, research at the University of Cincinnati has introduced a weak-link section (the fuse) at the mid-span of the coupling beam that will dissipate energy through shear yielding, leading to the development and modification of the steel fuse coupling beams. This would allow the plasticity at the face of the wall to be shifted to the mid-span of the coupling beam, requiring a feasible and economical repair involving only the replacement of the fuse at mid-span.","abstract_html":"Coupled core wall systems with steel coupling beams are effective seismic force resisting systems to resist structural collapse. A typical coupling beam shear wall system would dissipate energy through the formation of plastic hinges at the coupling beam-wall interface. These plastic hinges would damage the coupling beam, requiring an infeasible and uneconomical repair involving the replacement of the beam embedded in the concrete wall pier. However, research at the University of Cincinnati has introduced a weak-link section (the fuse) at the mid-span of the coupling beam that will dissipate energy through shear yielding, leading to the development and modification of the steel fuse coupling beams. This would allow the plasticity at the face of the wall to be shifted to the mid-span of the coupling beam, requiring a feasible and economical repair involving only the replacement of the fuse at mid-span.","abstract_has_math":false,"creators":["Ficker, Kyle A., M.S."],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering and Applied Science: Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Rassati, Gian"],"committee_members":[],"year":2014,"date_issued":"2014-07-11","date_published":"2014-07-11","updated_at":"2026-11-27T04:39:27Z","subjects":["Civil Engineering","coupled core wall","coupling beam","seismic performance factor","steel fuse coupling beam","FEMA P695"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1396454864","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1396454864","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1396454864","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1396454864","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Rassati, Gian"]},{"key":"dc:creator","label":"Author","values":["Ficker, Kyle A., M.S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-07-11"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","coupled core wall","coupling beam","seismic performance factor","steel fuse coupling beam","FEMA P695"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1396454864"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Coupled core wall systems with steel coupling beams are effective seismic force resisting systems to resist structural collapse. A typical coupling beam shear wall system would dissipate energy through the formation of plastic hinges at the coupling beam-wall interface. These plastic hinges would damage the coupling beam, requiring an infeasible and uneconomical repair involving the replacement of the beam embedded in the concrete wall pier. However, research at the University of Cincinnati has introduced a weak-link section (the fuse) at the mid-span of the coupling beam that will dissipate energy through shear yielding, leading to the development and modification of the steel fuse coupling beams. This would allow the plasticity at the face of the wall to be shifted to the mid-span of the coupling beam, requiring a feasible and economical repair involving only the replacement of the fuse at mid-span."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.123","2.09 MB"]},{"key":"dc:title","label":"Title","values":["Evaluation of the Seismic Performance Factors for Hybrid Coupled Core Wall Systems with Steel Fuse Coupling Beams"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Rassati, Gian"],"dc:creator":["Ficker, Kyle A., M.S."],"dc:date":["2014-07-11"],"dc:description":["Coupled core wall systems with steel coupling beams are effective seismic force resisting systems to resist structural collapse. A typical coupling beam shear wall system would dissipate energy through the formation of plastic hinges at the coupling beam-wall interface. These plastic hinges would damage the coupling beam, requiring an infeasible and uneconomical repair involving the replacement of the beam embedded in the concrete wall pier. However, research at the University of Cincinnati has introduced a weak-link section (the fuse) at the mid-span of the coupling beam that will dissipate energy through shear yielding, leading to the development and modification of the steel fuse coupling beams. This would allow the plasticity at the face of the wall to be shifted to the mid-span of the coupling beam, requiring a feasible and economical repair involving only the replacement of the fuse at mid-span."],"dc:format":["application/pdf","p.123","2.09 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1396454864"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Civil Engineering","coupled core wall","coupling beam","seismic performance factor","steel fuse coupling beam","FEMA P695"],"dc:title":["Evaluation of the Seismic Performance Factors for Hybrid Coupled Core Wall Systems with Steel Fuse Coupling Beams"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:39:27Z"}