{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1428066046"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1428066046","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Single Position Focusing of Cells in a Microchannel System","abstract":"The ability to focus and separate cells is invaluable in the area of cellular research. Inertial microfluidics uses the intrinsic physical properties of cells for manipulation and separation. Previous microfluidic devices use external controls in order to achieve focusing of cells into a single position. In this thesis we have examined a microfluidic device that exhibits inertial lift force as the only control to manipulate cells into a single position. We demonstrated that this device could handle variation of cell size and still achieve high efficiency and throughput. The device was verified for efficiency, throughput, recovery, and cell viability. The efficiency was reported at 99%, the throughput was reported at 850 cells per second, the recovery was reported at 99% and the cell viability were shown by incubation post device run. The simplified device offers many advantages over current methods, due to the simplified geometry, the ability for modification, and the flexibility in sample size variation.","abstract_html":"The ability to focus and separate cells is invaluable in the area of cellular research. Inertial microfluidics uses the intrinsic physical properties of cells for manipulation and separation. Previous microfluidic devices use external controls in order to achieve focusing of cells into a single position. In this thesis we have examined a microfluidic device that exhibits inertial lift force as the only control to manipulate cells into a single position. We demonstrated that this device could handle variation of cell size and still achieve high efficiency and throughput. The device was verified for efficiency, throughput, recovery, and cell viability. The efficiency was reported at 99%, the throughput was reported at 850 cells per second, the recovery was reported at 99% and the cell viability were shown by incubation post device run. The simplified device offers many advantages over current methods, due to the simplified geometry, the ability for modification, and the flexibility in sample size variation.","abstract_has_math":false,"creators":["Zandi, Matthew A."],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering and Applied Science: Chemical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Ho, Chia Chi"],"committee_members":[],"year":2015,"date_issued":"2015-09-04","date_published":"2015-09-04","updated_at":"2026-11-27T04:40:14Z","subjects":["Chemical Engineering","Focusing","Cell","Microchannel","Inertial Force"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1428066046","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1428066046","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1428066046","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1428066046","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Ho, Chia Chi"]},{"key":"dc:creator","label":"Author","values":["Zandi, Matthew A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-04"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical Engineering","Focusing","Cell","Microchannel","Inertial Force"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1428066046"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The ability to focus and separate cells is invaluable in the area of cellular research. Inertial microfluidics uses the intrinsic physical properties of cells for manipulation and separation. Previous microfluidic devices use external controls in order to achieve focusing of cells into a single position. In this thesis we have examined a microfluidic device that exhibits inertial lift force as the only control to manipulate cells into a single position. We demonstrated that this device could handle variation of cell size and still achieve high efficiency and throughput. The device was verified for efficiency, throughput, recovery, and cell viability. The efficiency was reported at 99%, the throughput was reported at 850 cells per second, the recovery was reported at 99% and the cell viability were shown by incubation post device run. The simplified device offers many advantages over current methods, due to the simplified geometry, the ability for modification, and the flexibility in sample size variation."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.22","3. MB"]},{"key":"dc:title","label":"Title","values":["Single Position Focusing of Cells in a Microchannel System"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Ho, Chia Chi"],"dc:creator":["Zandi, Matthew A."],"dc:date":["2015-09-04"],"dc:description":["The ability to focus and separate cells is invaluable in the area of cellular research. Inertial microfluidics uses the intrinsic physical properties of cells for manipulation and separation. Previous microfluidic devices use external controls in order to achieve focusing of cells into a single position. In this thesis we have examined a microfluidic device that exhibits inertial lift force as the only control to manipulate cells into a single position. We demonstrated that this device could handle variation of cell size and still achieve high efficiency and throughput. The device was verified for efficiency, throughput, recovery, and cell viability. The efficiency was reported at 99%, the throughput was reported at 850 cells per second, the recovery was reported at 99% and the cell viability were shown by incubation post device run. The simplified device offers many advantages over current methods, due to the simplified geometry, the ability for modification, and the flexibility in sample size variation."],"dc:format":["application/pdf","p.22","3. MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1428066046"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Chemical Engineering","Focusing","Cell","Microchannel","Inertial Force"],"dc:title":["Single Position Focusing of Cells in a Microchannel System"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Chemical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:40:14Z"}