{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1471346294"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1471346294","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Point-of-care Sensors for Determination of Manganese in Clinical Applications","abstract":"Chronic exposure to elevated levels of manganese (Mn) can lead to a wide range of health issues. Both the World Health Organization (WHO) and the US Agency for Toxic Substances and Disease Registry (ATSDR) have established safely limits for Mn in water and blood. To protect public health and the environment, it is critically important to monitor concentrations of Mn, so that clinicians and environmental scientists can take immediate action when necessary. The conventional approaches to monitoring Mn, such as ICP-MS or AAS, are extremely accurate, but are costly and are not suitable for fast response. A point-of-care system featuring electrochemical sensing can meet the requirements of a simple, cost-efficient, but highly sensitive analytical tool. This dissertation describes development of a microscale electrochemical sensor for determination of Mn using cathodic stripping voltammetry. The explored sensors include a copper (Cu)-based sensor with palladium (Pd) film working electrode, a platinum (Pt) sensor, and an indium tin oxide (ITO) sensor. With proper characterization of electrodes and optimization of parameters, a sufficiently low limit of detection (LOD) can be achieved. For example, the Cu-Pd sensor on glass substrate demonstrated LOD of 333.6 nM (18.3 ppb) in pH 9.0, 0.1 M borate buffer. For the Pt sensor, the LOD improved to 16.3 nM (0.9 ppb) in pH 5.5, 0.2 M acetate buffer, with similar performance for the ITO sensor. Using the Pt sensor, trace Mn concentrations were determined in natural water samples (pond water, river water, and well water) and achieved >97% precision and ~90% accuracy when we compared with ICP-MS. Using the ITO sensor, Mn was determined in digested whole blood samples. Ultimately, these results suggest that electrochemical sensors can enable sensitive and accurate on-site determination of Mn in various sample matrices. With additional development, these sensors can be integrated into a user-friendly portable system, which could potentially become a viable alternative to the conventional lab-based analysis for clinicians and environmental scientists.","abstract_html":"Chronic exposure to elevated levels of manganese (Mn) can lead to a wide range of health issues. Both the World Health Organization (WHO) and the US Agency for Toxic Substances and Disease Registry (ATSDR) have established safely limits for Mn in water and blood. To protect public health and the environment, it is critically important to monitor concentrations of Mn, so that clinicians and environmental scientists can take immediate action when necessary. The conventional approaches to monitoring Mn, such as ICP-MS or AAS, are extremely accurate, but are costly and are not suitable for fast response. A point-of-care system featuring electrochemical sensing can meet the requirements of a simple, cost-efficient, but highly sensitive analytical tool. This dissertation describes development of a microscale electrochemical sensor for determination of Mn using cathodic stripping voltammetry. The explored sensors include a copper (Cu)-based sensor with palladium (Pd) film working electrode, a platinum (Pt) sensor, and an indium tin oxide (ITO) sensor. With proper characterization of electrodes and optimization of parameters, a sufficiently low limit of detection (LOD) can be achieved. For example, the Cu-Pd sensor on glass substrate demonstrated LOD of 333.6 nM (18.3 ppb) in pH 9.0, 0.1 M borate buffer. For the Pt sensor, the LOD improved to 16.3 nM (0.9 ppb) in pH 5.5, 0.2 M acetate buffer, with similar performance for the ITO sensor. Using the Pt sensor, trace Mn concentrations were determined in natural water samples (pond water, river water, and well water) and achieved &gt;97% precision and ~90% accuracy when we compared with ICP-MS. Using the ITO sensor, Mn was determined in digested whole blood samples. Ultimately, these results suggest that electrochemical sensors can enable sensitive and accurate on-site determination of Mn in various sample matrices. With additional development, these sensors can be integrated into a user-friendly portable system, which could potentially become a viable alternative to the conventional lab-based analysis for clinicians and environmental scientists.","abstract_has_math":false,"creators":["Kang, Wenjing"],"institution":"University of Cincinnati","degree_name":"PhD","degree_level":"doctoral","degree_discipline":"Engineering and Applied Science: Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Papautsky, Ian"],"committee_members":[],"year":2016,"date_issued":"2016-09-13","date_published":"2016-09-13","updated_at":"2026-11-27T04:41:22Z","subjects":["Analytical Chemistry","Electrochemical sensors","Cathodic Stripping voltammetry","Manganese determination","Point-of-care","Environmental applications","Clinical applications"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1471346294","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1471346294","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1471346294","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1471346294","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Papautsky, Ian"]},{"key":"dc:creator","label":"Author","values":["Kang, Wenjing"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-09-13"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Analytical Chemistry","Electrochemical sensors","Cathodic Stripping voltammetry","Manganese determination","Point-of-care","Environmental applications","Clinical applications"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1471346294"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Chronic exposure to elevated levels of manganese (Mn) can lead to a wide range of health issues. Both the World Health Organization (WHO) and the US Agency for Toxic Substances and Disease Registry (ATSDR) have established safely limits for Mn in water and blood. To protect public health and the environment, it is critically important to monitor concentrations of Mn, so that clinicians and environmental scientists can take immediate action when necessary. The conventional approaches to monitoring Mn, such as ICP-MS or AAS, are extremely accurate, but are costly and are not suitable for fast response. A point-of-care system featuring electrochemical sensing can meet the requirements of a simple, cost-efficient, but highly sensitive analytical tool. This dissertation describes development of a microscale electrochemical sensor for determination of Mn using cathodic stripping voltammetry. The explored sensors include a copper (Cu)-based sensor with palladium (Pd) film working electrode, a platinum (Pt) sensor, and an indium tin oxide (ITO) sensor. With proper characterization of electrodes and optimization of parameters, a sufficiently low limit of detection (LOD) can be achieved. For example, the Cu-Pd sensor on glass substrate demonstrated LOD of 333.6 nM (18.3 ppb) in pH 9.0, 0.1 M borate buffer. For the Pt sensor, the LOD improved to 16.3 nM (0.9 ppb) in pH 5.5, 0.2 M acetate buffer, with similar performance for the ITO sensor. Using the Pt sensor, trace Mn concentrations were determined in natural water samples (pond water, river water, and well water) and achieved >97% precision and ~90% accuracy when we compared with ICP-MS. Using the ITO sensor, Mn was determined in digested whole blood samples. Ultimately, these results suggest that electrochemical sensors can enable sensitive and accurate on-site determination of Mn in various sample matrices. With additional development, these sensors can be integrated into a user-friendly portable system, which could potentially become a viable alternative to the conventional lab-based analysis for clinicians and environmental scientists."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.92","5.31 MB"]},{"key":"dc:title","label":"Title","values":["Point-of-care Sensors for Determination of Manganese in Clinical Applications"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Papautsky, Ian"],"dc:creator":["Kang, Wenjing"],"dc:date":["2016-09-13"],"dc:description":["Chronic exposure to elevated levels of manganese (Mn) can lead to a wide range of health issues. Both the World Health Organization (WHO) and the US Agency for Toxic Substances and Disease Registry (ATSDR) have established safely limits for Mn in water and blood. To protect public health and the environment, it is critically important to monitor concentrations of Mn, so that clinicians and environmental scientists can take immediate action when necessary. The conventional approaches to monitoring Mn, such as ICP-MS or AAS, are extremely accurate, but are costly and are not suitable for fast response. A point-of-care system featuring electrochemical sensing can meet the requirements of a simple, cost-efficient, but highly sensitive analytical tool. This dissertation describes development of a microscale electrochemical sensor for determination of Mn using cathodic stripping voltammetry. The explored sensors include a copper (Cu)-based sensor with palladium (Pd) film working electrode, a platinum (Pt) sensor, and an indium tin oxide (ITO) sensor. With proper characterization of electrodes and optimization of parameters, a sufficiently low limit of detection (LOD) can be achieved. For example, the Cu-Pd sensor on glass substrate demonstrated LOD of 333.6 nM (18.3 ppb) in pH 9.0, 0.1 M borate buffer. For the Pt sensor, the LOD improved to 16.3 nM (0.9 ppb) in pH 5.5, 0.2 M acetate buffer, with similar performance for the ITO sensor. Using the Pt sensor, trace Mn concentrations were determined in natural water samples (pond water, river water, and well water) and achieved >97% precision and ~90% accuracy when we compared with ICP-MS. Using the ITO sensor, Mn was determined in digested whole blood samples. Ultimately, these results suggest that electrochemical sensors can enable sensitive and accurate on-site determination of Mn in various sample matrices. With additional development, these sensors can be integrated into a user-friendly portable system, which could potentially become a viable alternative to the conventional lab-based analysis for clinicians and environmental scientists."],"dc:format":["application/pdf","p.92","5.31 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1471346294"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Analytical Chemistry","Electrochemical sensors","Cathodic Stripping voltammetry","Manganese determination","Point-of-care","Environmental applications","Clinical applications"],"dc:title":["Point-of-care Sensors for Determination of Manganese in Clinical Applications"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["PhD"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:41:22Z"}