{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin161710655436974"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin161710655436974","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Experimental Analysis of the Use of 0.7-in. Diameter Strand in Prestressed Concrete Bridge Girders","abstract":"The LRFD Bridge Design Specifications (LRFD-8) govern the design and construction of prestressed concrete bridge girders in the United States and currently does not address the use of prestressing strands larger than 0.6-in. dia. Larger, 0.7-in. dia. strands have the potential to permit longer spans, shallower girder depths, and/or less congested cross-sections. Relatively few studies have been performed on full-scale beams utilizing the larger strand. Further research is required to investigate how the provisions of LRFD-8 apply to 0.7-in. dia. strands, and if changes are needed to accommodate the use of the larger strand. In this thesis, the performance of full-scale bridge girders was investigated with respect to key provisions of LRFD-8. Various cross-sections, concrete strengths, reinforcement levels, and debonding levels were tested to investigate effects on (1) transfer length, (2) development length, (3) end-zone confinement performance (4) flexural behavior, and (5) shear behavior. To investigate these issues, 12 full-scale girders were fabricated and tested to failure; these tests are reported here. The results of these tests indicate that the LRFD-8 provisions for transfer and development length are conservative for 0.7-in. dia. strands – as they are for smaller diameters. Measured girder capacities exceeded the LRFD-8 predicted capacities, except where confinement reinforcement was not sufficiently extended beyond the debonding termination point. While some states require confinement to be extend further in the presence of debonded strands, LRFD-8 only requires confinement reinforcement to extended 1.5d from the girder end. Extending confinement reinforcement 1.5d beyond the debonding termination point improved ductility and performance at extreme load levels in girders with debonded strands.","abstract_html":"The LRFD Bridge Design Specifications (LRFD-8) govern the design and construction of prestressed concrete bridge girders in the United States and currently does not address the use of prestressing strands larger than 0.6-in. dia. Larger, 0.7-in. dia. strands have the potential to permit longer spans, shallower girder depths, and/or less congested cross-sections. Relatively few studies have been performed on full-scale beams utilizing the larger strand. Further research is required to investigate how the provisions of LRFD-8 apply to 0.7-in. dia. strands, and if changes are needed to accommodate the use of the larger strand. In this thesis, the performance of full-scale bridge girders was investigated with respect to key provisions of LRFD-8. Various cross-sections, concrete strengths, reinforcement levels, and debonding levels were tested to investigate effects on (1) transfer length, (2) development length, (3) end-zone confinement performance (4) flexural behavior, and (5) shear behavior. To investigate these issues, 12 full-scale girders were fabricated and tested to failure; these tests are reported here. The results of these tests indicate that the LRFD-8 provisions for transfer and development length are conservative for 0.7-in. dia. strands – as they are for smaller diameters. Measured girder capacities exceeded the LRFD-8 predicted capacities, except where confinement reinforcement was not sufficiently extended beyond the debonding termination point. While some states require confinement to be extend further in the presence of debonded strands, LRFD-8 only requires confinement reinforcement to extended 1.5d from the girder end. Extending confinement reinforcement 1.5d beyond the debonding termination point improved ductility and performance at extreme load levels in girders with debonded strands.","abstract_has_math":false,"creators":["Tamayo, Carlos A."],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering and Applied Science: Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Shahrooz, Bahram"],"committee_members":[],"year":2021,"date_issued":"2021-09-30","date_published":"2021-09-30","updated_at":"2026-11-27T04:50:09Z","subjects":["Civil Engineering","seven tenths inch diameter strands","prestressing stand debonding","confinement reinforcement","prestressed girder"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin161710655436974","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin161710655436974","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin161710655436974","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin161710655436974","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Shahrooz, Bahram"]},{"key":"dc:creator","label":"Author","values":["Tamayo, Carlos A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-09-30"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil Engineering","seven tenths inch diameter strands","prestressing stand debonding","confinement reinforcement","prestressed girder"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin161710655436974"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The LRFD Bridge Design Specifications (LRFD-8) govern the design and construction of prestressed concrete bridge girders in the United States and currently does not address the use of prestressing strands larger than 0.6-in. dia. Larger, 0.7-in. dia. strands have the potential to permit longer spans, shallower girder depths, and/or less congested cross-sections. Relatively few studies have been performed on full-scale beams utilizing the larger strand. Further research is required to investigate how the provisions of LRFD-8 apply to 0.7-in. dia. strands, and if changes are needed to accommodate the use of the larger strand. In this thesis, the performance of full-scale bridge girders was investigated with respect to key provisions of LRFD-8. Various cross-sections, concrete strengths, reinforcement levels, and debonding levels were tested to investigate effects on (1) transfer length, (2) development length, (3) end-zone confinement performance (4) flexural behavior, and (5) shear behavior. To investigate these issues, 12 full-scale girders were fabricated and tested to failure; these tests are reported here. The results of these tests indicate that the LRFD-8 provisions for transfer and development length are conservative for 0.7-in. dia. strands – as they are for smaller diameters. Measured girder capacities exceeded the LRFD-8 predicted capacities, except where confinement reinforcement was not sufficiently extended beyond the debonding termination point. While some states require confinement to be extend further in the presence of debonded strands, LRFD-8 only requires confinement reinforcement to extended 1.5d from the girder end. Extending confinement reinforcement 1.5d beyond the debonding termination point improved ductility and performance at extreme load levels in girders with debonded strands."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.181","27.23 MB"]},{"key":"dc:title","label":"Title","values":["Experimental Analysis of the Use of 0.7-in. Diameter Strand in Prestressed Concrete Bridge Girders"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Shahrooz, Bahram"],"dc:creator":["Tamayo, Carlos A."],"dc:date":["2021-09-30"],"dc:description":["The LRFD Bridge Design Specifications (LRFD-8) govern the design and construction of prestressed concrete bridge girders in the United States and currently does not address the use of prestressing strands larger than 0.6-in. dia. Larger, 0.7-in. dia. strands have the potential to permit longer spans, shallower girder depths, and/or less congested cross-sections. Relatively few studies have been performed on full-scale beams utilizing the larger strand. Further research is required to investigate how the provisions of LRFD-8 apply to 0.7-in. dia. strands, and if changes are needed to accommodate the use of the larger strand. In this thesis, the performance of full-scale bridge girders was investigated with respect to key provisions of LRFD-8. Various cross-sections, concrete strengths, reinforcement levels, and debonding levels were tested to investigate effects on (1) transfer length, (2) development length, (3) end-zone confinement performance (4) flexural behavior, and (5) shear behavior. To investigate these issues, 12 full-scale girders were fabricated and tested to failure; these tests are reported here. The results of these tests indicate that the LRFD-8 provisions for transfer and development length are conservative for 0.7-in. dia. strands – as they are for smaller diameters. Measured girder capacities exceeded the LRFD-8 predicted capacities, except where confinement reinforcement was not sufficiently extended beyond the debonding termination point. While some states require confinement to be extend further in the presence of debonded strands, LRFD-8 only requires confinement reinforcement to extended 1.5d from the girder end. Extending confinement reinforcement 1.5d beyond the debonding termination point improved ductility and performance at extreme load levels in girders with debonded strands."],"dc:format":["application/pdf","p.181","27.23 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin161710655436974"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Civil Engineering","seven tenths inch diameter strands","prestressing stand debonding","confinement reinforcement","prestressed girder"],"dc:title":["Experimental Analysis of the Use of 0.7-in. Diameter Strand in Prestressed Concrete Bridge Girders"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:50:09Z"}