{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1657796469961839"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1657796469961839","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Optimizing the mechanical properties of a PLA/PCL thin film through the inclusion of PEG as a plasticizing agent","abstract":"Fetoscopic prenatal myelomeningocele (MMC) repair is a promising method for minimizing the severe neurological damages associated with spina bifida. Tatu et al. (2019) developed a polylactic acid (PLA) / polycaprolactone (PCL) (83/17) blend thin-film polymer patch specifically for this procedure. The patch possesses key characteristics such as biodegradability, watertightness, and self-expansion abilities that make it a more suitable option over other various materials typically used in surgical patches, such as Teflon (PTFE) or collagen. However, a downside to the PLA/PCL patch is its mechanical properties. The material is too strong to conform to the morphology of the surrounding tissue when implanted, causing pressure to the spinal cord that could result in hinderance to neurological development. In this study, we look to use the plasticizing effects of polyethylene glycol (PEG) to soften the patch and increase its flexibility. While using 0% PEG as a control, we also analyze the effect of various concentrations of PEG (1%, 5%, and 10%) on the patches original properties (thickness, watertightness, and self-expansion ability) as these need to be preserved to ensure the patch can perform optimally as a MMC repair patch.","abstract_html":"Fetoscopic prenatal myelomeningocele (MMC) repair is a promising method for minimizing the severe neurological damages associated with spina bifida. Tatu et al. (2019) developed a polylactic acid (PLA) / polycaprolactone (PCL) (83/17) blend thin-film polymer patch specifically for this procedure. The patch possesses key characteristics such as biodegradability, watertightness, and self-expansion abilities that make it a more suitable option over other various materials typically used in surgical patches, such as Teflon (PTFE) or collagen. However, a downside to the PLA/PCL patch is its mechanical properties. The material is too strong to conform to the morphology of the surrounding tissue when implanted, causing pressure to the spinal cord that could result in hinderance to neurological development. In this study, we look to use the plasticizing effects of polyethylene glycol (PEG) to soften the patch and increase its flexibility. While using 0% PEG as a control, we also analyze the effect of various concentrations of PEG (1%, 5%, and 10%) on the patches original properties (thickness, watertightness, and self-expansion ability) as these need to be preserved to ensure the patch can perform optimally as a MMC repair patch.","abstract_has_math":false,"creators":["Kuhn, Alexander"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering and Applied Science: Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-08-23","date_published":"2022-08-23","updated_at":"2026-11-27T04:50:43Z","subjects":["Biomedical Engineering","spina bifida","fetoscopic MMC repair","biomaterials","thin film","plasticizer","bioompatibility"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1657796469961839","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1657796469961839","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1657796469961839","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1657796469961839","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kuhn, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-08-23"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","spina bifida","fetoscopic MMC repair","biomaterials","thin film","plasticizer","bioompatibility"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1657796469961839"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Fetoscopic prenatal myelomeningocele (MMC) repair is a promising method for minimizing the severe neurological damages associated with spina bifida. Tatu et al. (2019) developed a polylactic acid (PLA) / polycaprolactone (PCL) (83/17) blend thin-film polymer patch specifically for this procedure. The patch possesses key characteristics such as biodegradability, watertightness, and self-expansion abilities that make it a more suitable option over other various materials typically used in surgical patches, such as Teflon (PTFE) or collagen. However, a downside to the PLA/PCL patch is its mechanical properties. The material is too strong to conform to the morphology of the surrounding tissue when implanted, causing pressure to the spinal cord that could result in hinderance to neurological development. In this study, we look to use the plasticizing effects of polyethylene glycol (PEG) to soften the patch and increase its flexibility. While using 0% PEG as a control, we also analyze the effect of various concentrations of PEG (1%, 5%, and 10%) on the patches original properties (thickness, watertightness, and self-expansion ability) as these need to be preserved to ensure the patch can perform optimally as a MMC repair patch."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.37","3.66 MB"]},{"key":"dc:title","label":"Title","values":["Optimizing the mechanical properties of a PLA/PCL thin film through the inclusion of PEG as a plasticizing agent"]}]}],"canonical_facts":{"dc:creator":["Kuhn, Alexander"],"dc:date":["2022-08-23"],"dc:description":["Fetoscopic prenatal myelomeningocele (MMC) repair is a promising method for minimizing the severe neurological damages associated with spina bifida. Tatu et al. (2019) developed a polylactic acid (PLA) / polycaprolactone (PCL) (83/17) blend thin-film polymer patch specifically for this procedure. The patch possesses key characteristics such as biodegradability, watertightness, and self-expansion abilities that make it a more suitable option over other various materials typically used in surgical patches, such as Teflon (PTFE) or collagen. However, a downside to the PLA/PCL patch is its mechanical properties. The material is too strong to conform to the morphology of the surrounding tissue when implanted, causing pressure to the spinal cord that could result in hinderance to neurological development. In this study, we look to use the plasticizing effects of polyethylene glycol (PEG) to soften the patch and increase its flexibility. While using 0% PEG as a control, we also analyze the effect of various concentrations of PEG (1%, 5%, and 10%) on the patches original properties (thickness, watertightness, and self-expansion ability) as these need to be preserved to ensure the patch can perform optimally as a MMC repair patch."],"dc:format":["application/pdf","p.37","3.66 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1657796469961839"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","spina bifida","fetoscopic MMC repair","biomaterials","thin film","plasticizer","bioompatibility"],"dc:title":["Optimizing the mechanical properties of a PLA/PCL thin film through the inclusion of PEG as a plasticizing agent"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:50:43Z"}