{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin1712913075736246"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin1712913075736246","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Three-dimensional ultrasound echo decorrelation imaging for real-time monitoring and control of thermal ablation in liver parenchyma and tumors","abstract":"Thermal ablation, including radiofrequency (RFA) and microwave ablation (MWA), is a potential first-line treatment for many patients with small liver tumors. Real-time monitoring and control methods can potentially reduce under- or over-treatment rates. Here, echo decorrelation imaging was expanded from two- to three-dimensional (3D) imaging, and its performance was assessed in ex vivo and in vivo.First, 3D echo decorrelation with three normalization approaches and 3D integrated backscatter (IBS) were used to monitor ex vivo bovine liver RFA. Receiver-operating characteristic (ROC) curves, comparing these imaging parameters to ablation zones, indicated that all four were potentially good predictors of local RFA. Tissue temperatures, recorded at four thermocouples locations, weakly correlated with co-located measured decorrelation. In tests predicting ablation zones using a weighted K-means clustering approach, echo decorrelation performed better than IBS, with smaller root mean square (RMS) volume errors and higher Dice coefficients between predicted and measured ablation zones.Further, RFA in samples from normal, steatotic, and cirrhotic human liver parenchyma was monitored and controlled using 3D echo decorrelation imaging feedback. For each liver type, N=14 samples underwent ablation per RFA generator’s settings, monitored by echo decorrelation imaging (uncontrolled). In N>14 trials, RFA was controlled, automatically ceasing if the average cumulative decorrelation within the target region of interest surpassed the control threshold (successfully controlled), otherwise, ablation continued like the uncontrolled trials (unsuccessfully controlled). ROC curves showed good prediction performance for all liver and control conditions. Significantly higher control success rate and generally higher measured ablation volume were observed in controlling normal vs. diseased liver. The same monitoring and control algorithms were used in in vivo swine liver RFA, employing motion-corrected echo decorrelation imaging. ROC curves showed better performance for controlled vs. uncontrolled trials and for motion-corrected vs. uncorrected echo decorrelation in controlled trials. Lower ablation volumes and higher ablation rates were observed for the controlled vs. uncontrolled trials.To reduce echo decorrelation’s limitations in mapping ablation zone and tissue temperature, deep learning methods were investigated in ex vivo human liver RFA. A neural network trained on local echo decorrelation, minimizing mean-squared error vs. measured temperatures, showed significantly correlated predictions vs. measurements. According to ROC and PR curves, average Dice coefficients between predicted and measured ablation zones, and RMS volume error, 3D U-Net convolutional neural networks processing echo decorrelation predicted ablation zones significantly better than thresholding of decorrelation maps.Finally, 3D echo decorrelation imaging was evaluated in monitoring standard-of-care percutaneous MWA of human liver tumors. Registration between B-mode image and follow-up CT/MRI was applied to decorrelation with and without motion correction and IBS maps. ROC and PR curves determined successful ablation prediction by echo decorrelation and IBS imaging. Motion correction improved predictability of the echo decorrelation images. A weighted K-means method predicted ablation better than target ablation zone provided by the MWA generator’s instruction for use, with smaller RMS error and higher correlation coefficients for prediction of ablation volume.These results support the potential of 3D echo decorrelation imaging in real-time monitoring and control of thermal ablation in liver parenchyma and tumors.","abstract_html":"Thermal ablation, including radiofrequency (RFA) and microwave ablation (MWA), is a potential first-line treatment for many patients with small liver tumors. Real-time monitoring and control methods can potentially reduce under- or over-treatment rates. Here, echo decorrelation imaging was expanded from two- to three-dimensional (3D) imaging, and its performance was assessed in ex vivo and in vivo.First, 3D echo decorrelation with three normalization approaches and 3D integrated backscatter (IBS) were used to monitor ex vivo bovine liver RFA. Receiver-operating characteristic (ROC) curves, comparing these imaging parameters to ablation zones, indicated that all four were potentially good predictors of local RFA. Tissue temperatures, recorded at four thermocouples locations, weakly correlated with co-located measured decorrelation. In tests predicting ablation zones using a weighted K-means clustering approach, echo decorrelation performed better than IBS, with smaller root mean square (RMS) volume errors and higher Dice coefficients between predicted and measured ablation zones.Further, RFA in samples from normal, steatotic, and cirrhotic human liver parenchyma was monitored and controlled using 3D echo decorrelation imaging feedback. For each liver type, N=14 samples underwent ablation per RFA generator’s settings, monitored by echo decorrelation imaging (uncontrolled). In N&gt;14 trials, RFA was controlled, automatically ceasing if the average cumulative decorrelation within the target region of interest surpassed the control threshold (successfully controlled), otherwise, ablation continued like the uncontrolled trials (unsuccessfully controlled). ROC curves showed good prediction performance for all liver and control conditions. Significantly higher control success rate and generally higher measured ablation volume were observed in controlling normal vs. diseased liver. The same monitoring and control algorithms were used in in vivo swine liver RFA, employing motion-corrected echo decorrelation imaging. ROC curves showed better performance for controlled vs. uncontrolled trials and for motion-corrected vs. uncorrected echo decorrelation in controlled trials. Lower ablation volumes and higher ablation rates were observed for the controlled vs. uncontrolled trials.To reduce echo decorrelation’s limitations in mapping ablation zone and tissue temperature, deep learning methods were investigated in ex vivo human liver RFA. A neural network trained on local echo decorrelation, minimizing mean-squared error vs. measured temperatures, showed significantly correlated predictions vs. measurements. According to ROC and PR curves, average Dice coefficients between predicted and measured ablation zones, and RMS volume error, 3D U-Net convolutional neural networks processing echo decorrelation predicted ablation zones significantly better than thresholding of decorrelation maps.Finally, 3D echo decorrelation imaging was evaluated in monitoring standard-of-care percutaneous MWA of human liver tumors. Registration between B-mode image and follow-up CT/MRI was applied to decorrelation with and without motion correction and IBS maps. ROC and PR curves determined successful ablation prediction by echo decorrelation and IBS imaging. Motion correction improved predictability of the echo decorrelation images. A weighted K-means method predicted ablation better than target ablation zone provided by the MWA generator’s instruction for use, with smaller RMS error and higher correlation coefficients for prediction of ablation volume.These results support the potential of 3D echo decorrelation imaging in real-time monitoring and control of thermal ablation in liver parenchyma and tumors.","abstract_has_math":false,"creators":["Ghahramani Zarajabad, Elmira"],"institution":"University of Cincinnati","degree_name":"PhD","degree_level":"doctoral","degree_discipline":"Engineering and Applied Science: Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Mast, T. Douglas"],"committee_members":[],"year":2024,"date_issued":"2024-06-26","date_published":"2024-06-26","updated_at":"2026-11-27T04:59:13Z","subjects":["Biomedical Engineering","3D ultrasound echo decorrelation imaging","Image-guided thermal ablation","Real-time ablation control","Deep learning","Weighted K-means classification","Liver disease"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1712913075736246","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin1712913075736246","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin1712913075736246","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin1712913075736246","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Mast, T. Douglas"]},{"key":"dc:creator","label":"Author","values":["Ghahramani Zarajabad, Elmira"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-06-26"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering and Applied Science: Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","3D ultrasound echo decorrelation imaging","Image-guided thermal ablation","Real-time ablation control","Deep learning","Weighted K-means classification","Liver disease"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1712913075736246"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thermal ablation, including radiofrequency (RFA) and microwave ablation (MWA), is a potential first-line treatment for many patients with small liver tumors. Real-time monitoring and control methods can potentially reduce under- or over-treatment rates. Here, echo decorrelation imaging was expanded from two- to three-dimensional (3D) imaging, and its performance was assessed in ex vivo and in vivo.First, 3D echo decorrelation with three normalization approaches and 3D integrated backscatter (IBS) were used to monitor ex vivo bovine liver RFA. Receiver-operating characteristic (ROC) curves, comparing these imaging parameters to ablation zones, indicated that all four were potentially good predictors of local RFA. Tissue temperatures, recorded at four thermocouples locations, weakly correlated with co-located measured decorrelation. In tests predicting ablation zones using a weighted K-means clustering approach, echo decorrelation performed better than IBS, with smaller root mean square (RMS) volume errors and higher Dice coefficients between predicted and measured ablation zones.Further, RFA in samples from normal, steatotic, and cirrhotic human liver parenchyma was monitored and controlled using 3D echo decorrelation imaging feedback. For each liver type, N=14 samples underwent ablation per RFA generator’s settings, monitored by echo decorrelation imaging (uncontrolled). In N>14 trials, RFA was controlled, automatically ceasing if the average cumulative decorrelation within the target region of interest surpassed the control threshold (successfully controlled), otherwise, ablation continued like the uncontrolled trials (unsuccessfully controlled). ROC curves showed good prediction performance for all liver and control conditions. Significantly higher control success rate and generally higher measured ablation volume were observed in controlling normal vs. diseased liver. The same monitoring and control algorithms were used in in vivo swine liver RFA, employing motion-corrected echo decorrelation imaging. ROC curves showed better performance for controlled vs. uncontrolled trials and for motion-corrected vs. uncorrected echo decorrelation in controlled trials. Lower ablation volumes and higher ablation rates were observed for the controlled vs. uncontrolled trials.To reduce echo decorrelation’s limitations in mapping ablation zone and tissue temperature, deep learning methods were investigated in ex vivo human liver RFA. A neural network trained on local echo decorrelation, minimizing mean-squared error vs. measured temperatures, showed significantly correlated predictions vs. measurements. According to ROC and PR curves, average Dice coefficients between predicted and measured ablation zones, and RMS volume error, 3D U-Net convolutional neural networks processing echo decorrelation predicted ablation zones significantly better than thresholding of decorrelation maps.Finally, 3D echo decorrelation imaging was evaluated in monitoring standard-of-care percutaneous MWA of human liver tumors. Registration between B-mode image and follow-up CT/MRI was applied to decorrelation with and without motion correction and IBS maps. ROC and PR curves determined successful ablation prediction by echo decorrelation and IBS imaging. Motion correction improved predictability of the echo decorrelation images. A weighted K-means method predicted ablation better than target ablation zone provided by the MWA generator’s instruction for use, with smaller RMS error and higher correlation coefficients for prediction of ablation volume.These results support the potential of 3D echo decorrelation imaging in real-time monitoring and control of thermal ablation in liver parenchyma and tumors."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.159","8.79 MB"]},{"key":"dc:title","label":"Title","values":["Three-dimensional ultrasound echo decorrelation imaging for real-time monitoring and control of thermal ablation in liver parenchyma and tumors"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Mast, T. Douglas"],"dc:creator":["Ghahramani Zarajabad, Elmira"],"dc:date":["2024-06-26"],"dc:description":["Thermal ablation, including radiofrequency (RFA) and microwave ablation (MWA), is a potential first-line treatment for many patients with small liver tumors. Real-time monitoring and control methods can potentially reduce under- or over-treatment rates. Here, echo decorrelation imaging was expanded from two- to three-dimensional (3D) imaging, and its performance was assessed in ex vivo and in vivo.First, 3D echo decorrelation with three normalization approaches and 3D integrated backscatter (IBS) were used to monitor ex vivo bovine liver RFA. Receiver-operating characteristic (ROC) curves, comparing these imaging parameters to ablation zones, indicated that all four were potentially good predictors of local RFA. Tissue temperatures, recorded at four thermocouples locations, weakly correlated with co-located measured decorrelation. In tests predicting ablation zones using a weighted K-means clustering approach, echo decorrelation performed better than IBS, with smaller root mean square (RMS) volume errors and higher Dice coefficients between predicted and measured ablation zones.Further, RFA in samples from normal, steatotic, and cirrhotic human liver parenchyma was monitored and controlled using 3D echo decorrelation imaging feedback. For each liver type, N=14 samples underwent ablation per RFA generator’s settings, monitored by echo decorrelation imaging (uncontrolled). In N>14 trials, RFA was controlled, automatically ceasing if the average cumulative decorrelation within the target region of interest surpassed the control threshold (successfully controlled), otherwise, ablation continued like the uncontrolled trials (unsuccessfully controlled). ROC curves showed good prediction performance for all liver and control conditions. Significantly higher control success rate and generally higher measured ablation volume were observed in controlling normal vs. diseased liver. The same monitoring and control algorithms were used in in vivo swine liver RFA, employing motion-corrected echo decorrelation imaging. ROC curves showed better performance for controlled vs. uncontrolled trials and for motion-corrected vs. uncorrected echo decorrelation in controlled trials. Lower ablation volumes and higher ablation rates were observed for the controlled vs. uncontrolled trials.To reduce echo decorrelation’s limitations in mapping ablation zone and tissue temperature, deep learning methods were investigated in ex vivo human liver RFA. A neural network trained on local echo decorrelation, minimizing mean-squared error vs. measured temperatures, showed significantly correlated predictions vs. measurements. According to ROC and PR curves, average Dice coefficients between predicted and measured ablation zones, and RMS volume error, 3D U-Net convolutional neural networks processing echo decorrelation predicted ablation zones significantly better than thresholding of decorrelation maps.Finally, 3D echo decorrelation imaging was evaluated in monitoring standard-of-care percutaneous MWA of human liver tumors. Registration between B-mode image and follow-up CT/MRI was applied to decorrelation with and without motion correction and IBS maps. ROC and PR curves determined successful ablation prediction by echo decorrelation and IBS imaging. Motion correction improved predictability of the echo decorrelation images. A weighted K-means method predicted ablation better than target ablation zone provided by the MWA generator’s instruction for use, with smaller RMS error and higher correlation coefficients for prediction of ablation volume.These results support the potential of 3D echo decorrelation imaging in real-time monitoring and control of thermal ablation in liver parenchyma and tumors."],"dc:format":["application/pdf","p.159","8.79 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin1712913075736246"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","3D ultrasound echo decorrelation imaging","Image-guided thermal ablation","Real-time ablation control","Deep learning","Weighted K-means classification","Liver disease"],"dc:title":["Three-dimensional ultrasound echo decorrelation imaging for real-time monitoring and control of thermal ablation in liver parenchyma and tumors"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering and Applied Science: Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["PhD"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:59:13Z"}