{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin974902659"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin974902659","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"EARTH PRESSURE ON RETAINING WALL NEAR ROCK FACE","abstract":"There are always cases in which retaining structures have to be constructed close to a stable rock face. In such cases, the fill between the retaining structure and the rock face is partly supported by friction on the wall and the rock face; subsequently, the theoretically assumed wedge of sliding soil cannot develop, and the vertical stress in the fill and the horizontal stress on the structure are reduced. Finite element analyses (FEA) were performed for this thesis to evaluate the effect of the interface friction on the magnitude and the distribution of the lateral earth pressure acting on the retaining structure. The analyses show that Coulomb's theory is very conservative and that modified silo theory can be used to evaluate the lateral earth pressure when the fill width is small. Finite element analyses also show that different base material and the friction angle between the fill-base interface may influence the magnitude and the distribution of the lateral earth pressure to a great degree.","abstract_html":"There are always cases in which retaining structures have to be constructed close to a stable rock face. In such cases, the fill between the retaining structure and the rock face is partly supported by friction on the wall and the rock face; subsequently, the theoretically assumed wedge of sliding soil cannot develop, and the vertical stress in the fill and the horizontal stress on the structure are reduced. Finite element analyses (FEA) were performed for this thesis to evaluate the effect of the interface friction on the magnitude and the distribution of the lateral earth pressure acting on the retaining structure. The analyses show that Coulomb&#x27;s theory is very conservative and that modified silo theory can be used to evaluate the lateral earth pressure when the fill width is small. Finite element analyses also show that different base material and the friction angle between the fill-base interface may influence the magnitude and the distribution of the lateral earth pressure to a great degree.","abstract_has_math":false,"creators":["ZHUANG, JUN"],"institution":"University of Cincinnati","degree_name":"MS","degree_level":"masters","degree_discipline":"Engineering : Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Bowers, Dr. Mark T."],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000","date_published":"2000","updated_at":"2026-11-27T04:38:24Z","subjects":["Engineering, Civil","earth pressure","retaining wall","finite element analysis"],"languages":["English"],"rights":["restricted--full text not available online","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin974902659","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin974902659","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin974902659","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin974902659","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bowers, Dr. Mark T."]},{"key":"dc:creator","label":"Author","values":["ZHUANG, JUN"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2000"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering : Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Civil","earth pressure","retaining wall","finite element analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["restricted--full text not available online","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin974902659"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["There are always cases in which retaining structures have to be constructed close to a stable rock face. In such cases, the fill between the retaining structure and the rock face is partly supported by friction on the wall and the rock face; subsequently, the theoretically assumed wedge of sliding soil cannot develop, and the vertical stress in the fill and the horizontal stress on the structure are reduced. Finite element analyses (FEA) were performed for this thesis to evaluate the effect of the interface friction on the magnitude and the distribution of the lateral earth pressure acting on the retaining structure. The analyses show that Coulomb's theory is very conservative and that modified silo theory can be used to evaluate the lateral earth pressure when the fill width is small. Finite element analyses also show that different base material and the friction angle between the fill-base interface may influence the magnitude and the distribution of the lateral earth pressure to a great degree."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.1"]},{"key":"dc:title","label":"Title","values":["EARTH PRESSURE ON RETAINING WALL NEAR ROCK FACE"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bowers, Dr. Mark T."],"dc:creator":["ZHUANG, JUN"],"dc:date":["2000"],"dc:description":["There are always cases in which retaining structures have to be constructed close to a stable rock face. In such cases, the fill between the retaining structure and the rock face is partly supported by friction on the wall and the rock face; subsequently, the theoretically assumed wedge of sliding soil cannot develop, and the vertical stress in the fill and the horizontal stress on the structure are reduced. Finite element analyses (FEA) were performed for this thesis to evaluate the effect of the interface friction on the magnitude and the distribution of the lateral earth pressure acting on the retaining structure. The analyses show that Coulomb's theory is very conservative and that modified silo theory can be used to evaluate the lateral earth pressure when the fill width is small. Finite element analyses also show that different base material and the friction angle between the fill-base interface may influence the magnitude and the distribution of the lateral earth pressure to a great degree."],"dc:format":["application/pdf","p.1"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin974902659"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["restricted--full text not available online","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Civil","earth pressure","retaining wall","finite element analysis"],"dc:title":["EARTH PRESSURE ON RETAINING WALL NEAR ROCK FACE"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering : Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["MS"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:38:24Z"}