{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:ucin976038470"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:ucin976038470","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"INTERFACES FOR LIQUID SAMPLE INTRODUCTION FOR INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY AND APPLICATIONS OF ELEMENTAL SPECIATION WITH ICP-MS DETECTION INCLUDING ARSENIC IN APPLES AND SELENIUM IN DIETARY FOOD SUPPLEMENTS","abstract":"Liquid sample introduction with inductively coupled plasma-mass spectrometry (ICP-MS) can be a key issue in the development of separation techniques used for elemental speciation. A two-tube oscillating capillary nebulizer (OCN) was developed and evaluated for interfacing both high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The chief theoretical advantage of the OCN is in its low flow operation which makes it well suited for the ICP. A number of commercial nebulizers and spray chambers were compared to the developed OCN equipped with a single pass spray chamber; all nebulizers were compared using ion-pair HPLC conditions. Observed detection limits for arsenic compounds separated were 160 to 360 ppb for the OCN verses 2.0 to 11 ppb for the conventional nebulizer combinations using a small bore (2 mm ID) column. Also, a microbore (1 mm ID) column using a commercial micronebulizer produced low detection limits for the arsenic compounds. Capillary electrophoresis is a low flow separation technique and is well suited for low flow nebulizers. All pneumatic nebulizers, however, have a problem with interfacing with CE. The aspiration generated by the nebulizer can greatly affect the flow rate through the capillary and compromise the CE separation. Different designs of CE OCN interfaces were tried using UV detection as a scouting technique. The use of a permeable frit in the sample side of the capillary was used to evaluate the OCN for possible ICP-MS interface. The novel concept of the fritted capillary was ultimately conducted on a more conventional micronebulizer. The application of elemental speciation to actual samples not previously studied was performed. Freeze-dried apple samples were studied for trace levels of various arsenic compounds using ion-exchange HPLC interfaced to the ICP-MS. Total arsenic levels of three apple samples were determined, as well as an evaluation of extraction techniques used for speciation. Finally, reversed-phase HPLC was used to study six different brands of yeast-based selenium dietary food supplements using ICP-MS detection. Although selenomethionine was the expected main component from yeast inoculated with selenium, only two of the brands of supplements showed high levels of selenomethionine. Two brands were found to contain high levels of inorganic selenium, and two brands had poor extraction results.","abstract_html":"Liquid sample introduction with inductively coupled plasma-mass spectrometry (ICP-MS) can be a key issue in the development of separation techniques used for elemental speciation. A two-tube oscillating capillary nebulizer (OCN) was developed and evaluated for interfacing both high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The chief theoretical advantage of the OCN is in its low flow operation which makes it well suited for the ICP. A number of commercial nebulizers and spray chambers were compared to the developed OCN equipped with a single pass spray chamber; all nebulizers were compared using ion-pair HPLC conditions. Observed detection limits for arsenic compounds separated were 160 to 360 ppb for the OCN verses 2.0 to 11 ppb for the conventional nebulizer combinations using a small bore (2 mm ID) column. Also, a microbore (1 mm ID) column using a commercial micronebulizer produced low detection limits for the arsenic compounds. Capillary electrophoresis is a low flow separation technique and is well suited for low flow nebulizers. All pneumatic nebulizers, however, have a problem with interfacing with CE. The aspiration generated by the nebulizer can greatly affect the flow rate through the capillary and compromise the CE separation. Different designs of CE OCN interfaces were tried using UV detection as a scouting technique. The use of a permeable frit in the sample side of the capillary was used to evaluate the OCN for possible ICP-MS interface. The novel concept of the fritted capillary was ultimately conducted on a more conventional micronebulizer. The application of elemental speciation to actual samples not previously studied was performed. Freeze-dried apple samples were studied for trace levels of various arsenic compounds using ion-exchange HPLC interfaced to the ICP-MS. Total arsenic levels of three apple samples were determined, as well as an evaluation of extraction techniques used for speciation. Finally, reversed-phase HPLC was used to study six different brands of yeast-based selenium dietary food supplements using ICP-MS detection. Although selenomethionine was the expected main component from yeast inoculated with selenium, only two of the brands of supplements showed high levels of selenomethionine. Two brands were found to contain high levels of inorganic selenium, and two brands had poor extraction results.","abstract_has_math":false,"creators":["B'Hymer, Clayton"],"institution":"University of Cincinnati","degree_name":"PhD","degree_level":"doctoral","degree_discipline":"Arts and Sciences : Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":["Caruso, Joseph"],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000","date_published":"2000","updated_at":"2026-11-27T04:38:24Z","subjects":["Chemistry, Analytical","Elemental Speculation","Inductively Coupled Plasma-Mass Spectrometry","Selenium","Arsenic"],"languages":["English"],"rights":["restricted--full text not available online","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin976038470","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=ucin976038470","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Aucin976038470","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Aucin976038470","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Caruso, Joseph"]},{"key":"dc:creator","label":"Author","values":["B'Hymer, Clayton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2000"]},{"key":"dc:publisher","label":"Institution","values":["University of Cincinnati / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Arts and Sciences : Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Cincinnati"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry, Analytical","Elemental Speculation","Inductively Coupled Plasma-Mass Spectrometry","Selenium","Arsenic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["restricted--full text not available online","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin976038470"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Liquid sample introduction with inductively coupled plasma-mass spectrometry (ICP-MS) can be a key issue in the development of separation techniques used for elemental speciation. A two-tube oscillating capillary nebulizer (OCN) was developed and evaluated for interfacing both high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The chief theoretical advantage of the OCN is in its low flow operation which makes it well suited for the ICP. A number of commercial nebulizers and spray chambers were compared to the developed OCN equipped with a single pass spray chamber; all nebulizers were compared using ion-pair HPLC conditions. Observed detection limits for arsenic compounds separated were 160 to 360 ppb for the OCN verses 2.0 to 11 ppb for the conventional nebulizer combinations using a small bore (2 mm ID) column. Also, a microbore (1 mm ID) column using a commercial micronebulizer produced low detection limits for the arsenic compounds. Capillary electrophoresis is a low flow separation technique and is well suited for low flow nebulizers. All pneumatic nebulizers, however, have a problem with interfacing with CE. The aspiration generated by the nebulizer can greatly affect the flow rate through the capillary and compromise the CE separation. Different designs of CE OCN interfaces were tried using UV detection as a scouting technique. The use of a permeable frit in the sample side of the capillary was used to evaluate the OCN for possible ICP-MS interface. The novel concept of the fritted capillary was ultimately conducted on a more conventional micronebulizer. The application of elemental speciation to actual samples not previously studied was performed. Freeze-dried apple samples were studied for trace levels of various arsenic compounds using ion-exchange HPLC interfaced to the ICP-MS. Total arsenic levels of three apple samples were determined, as well as an evaluation of extraction techniques used for speciation. Finally, reversed-phase HPLC was used to study six different brands of yeast-based selenium dietary food supplements using ICP-MS detection. Although selenomethionine was the expected main component from yeast inoculated with selenium, only two of the brands of supplements showed high levels of selenomethionine. Two brands were found to contain high levels of inorganic selenium, and two brands had poor extraction results."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["INTERFACES FOR LIQUID SAMPLE INTRODUCTION FOR INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY AND APPLICATIONS OF ELEMENTAL SPECIATION WITH ICP-MS DETECTION INCLUDING ARSENIC IN APPLES AND SELENIUM IN DIETARY FOOD SUPPLEMENTS"]}]}],"canonical_facts":{"dc:contributor.advisor":["Caruso, Joseph"],"dc:creator":["B'Hymer, Clayton"],"dc:date":["2000"],"dc:description":["Liquid sample introduction with inductively coupled plasma-mass spectrometry (ICP-MS) can be a key issue in the development of separation techniques used for elemental speciation. A two-tube oscillating capillary nebulizer (OCN) was developed and evaluated for interfacing both high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). The chief theoretical advantage of the OCN is in its low flow operation which makes it well suited for the ICP. A number of commercial nebulizers and spray chambers were compared to the developed OCN equipped with a single pass spray chamber; all nebulizers were compared using ion-pair HPLC conditions. Observed detection limits for arsenic compounds separated were 160 to 360 ppb for the OCN verses 2.0 to 11 ppb for the conventional nebulizer combinations using a small bore (2 mm ID) column. Also, a microbore (1 mm ID) column using a commercial micronebulizer produced low detection limits for the arsenic compounds. Capillary electrophoresis is a low flow separation technique and is well suited for low flow nebulizers. All pneumatic nebulizers, however, have a problem with interfacing with CE. The aspiration generated by the nebulizer can greatly affect the flow rate through the capillary and compromise the CE separation. Different designs of CE OCN interfaces were tried using UV detection as a scouting technique. The use of a permeable frit in the sample side of the capillary was used to evaluate the OCN for possible ICP-MS interface. The novel concept of the fritted capillary was ultimately conducted on a more conventional micronebulizer. The application of elemental speciation to actual samples not previously studied was performed. Freeze-dried apple samples were studied for trace levels of various arsenic compounds using ion-exchange HPLC interfaced to the ICP-MS. Total arsenic levels of three apple samples were determined, as well as an evaluation of extraction techniques used for speciation. Finally, reversed-phase HPLC was used to study six different brands of yeast-based selenium dietary food supplements using ICP-MS detection. Although selenomethionine was the expected main component from yeast inoculated with selenium, only two of the brands of supplements showed high levels of selenomethionine. Two brands were found to contain high levels of inorganic selenium, and two brands had poor extraction results."],"dc:format":["application/pdf"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=ucin976038470"],"dc:language":["English"],"dc:publisher":["University of Cincinnati / OhioLINK"],"dc:rights":["restricted--full text not available online","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Chemistry, Analytical","Elemental Speculation","Inductively Coupled Plasma-Mass Spectrometry","Selenium","Arsenic"],"dc:title":["INTERFACES FOR LIQUID SAMPLE INTRODUCTION FOR INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY AND APPLICATIONS OF ELEMENTAL SPECIATION WITH ICP-MS DETECTION INCLUDING ARSENIC IN APPLES AND SELENIUM IN DIETARY FOOD SUPPLEMENTS"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Arts and Sciences : Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["PhD"],"thesis:institution_name":["University of Cincinnati"]},"updated_at":"2026-11-27T04:38:24Z"}