{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1166490962"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1166490962","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Methodology for Quantifying Biomechanical Bone Movement of Transtibial Amputations","abstract":"A controversy has long existed about an alternate below knee amputation procedure that may be more beneficial than the traditional transtibial amputation. The proponents of this alternate procedure that stabilizes the distal tibia and fibula claim it reduces excessive movement of the fibula relative to the tibia that occurs with common movements, such as walking. The purpose of this study is to develop a methodology for quantifying excessive movement of the fibula bone relative to the tibia bone in traditional below the knee amputations. The methodology will measure the movement and rotation of the fibula relative to the tibia. These results can be compared to the bone movement from below the knee distal tibiofibular fusion procedure in order to observe if the excessive movement has been reduced. Matlab was used to analyze CT data from a traditional transtibial amputation subject and a distal tibiofibular fusion subject under four loading conditions. Distance and rotation measurements were collected using preexisting and generated Matlab programs. The measurements include locations from several regions on the limb to try to establish a trend for motion. A repeatable methodology with high precision was developed to quantify the movement of the fibula relative to the tibia for both distance and rotation measurements; the average standard deviation for distance measurement is 0.374 mm and the average standard deviation for rotation measurement is 0.131 degrees.","abstract_html":"A controversy has long existed about an alternate below knee amputation procedure that may be more beneficial than the traditional transtibial amputation. The proponents of this alternate procedure that stabilizes the distal tibia and fibula claim it reduces excessive movement of the fibula relative to the tibia that occurs with common movements, such as walking. The purpose of this study is to develop a methodology for quantifying excessive movement of the fibula bone relative to the tibia bone in traditional below the knee amputations. The methodology will measure the movement and rotation of the fibula relative to the tibia. These results can be compared to the bone movement from below the knee distal tibiofibular fusion procedure in order to observe if the excessive movement has been reduced. Matlab was used to analyze CT data from a traditional transtibial amputation subject and a distal tibiofibular fusion subject under four loading conditions. Distance and rotation measurements were collected using preexisting and generated Matlab programs. The measurements include locations from several regions on the limb to try to establish a trend for motion. A repeatable methodology with high precision was developed to quantify the movement of the fibula relative to the tibia for both distance and rotation measurements; the average standard deviation for distance measurement is 0.374 mm and the average standard deviation for rotation measurement is 0.131 degrees.","abstract_has_math":false,"creators":["Bell, Johanna C."],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["He, Ping","Reynolds, David"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-11-26T04:31:29Z","subjects":["Engineering, Biomedical","tibia","fibula","limb","loading conditions","Amputations","Bone"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1166490962","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1166490962","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1166490962","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1166490962","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["He, Ping","Reynolds, David"]},{"key":"dc:creator","label":"Author","values":["Bell, Johanna C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","tibia","fibula","limb","loading conditions","Amputations","Bone"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1166490962"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A controversy has long existed about an alternate below knee amputation procedure that may be more beneficial than the traditional transtibial amputation. The proponents of this alternate procedure that stabilizes the distal tibia and fibula claim it reduces excessive movement of the fibula relative to the tibia that occurs with common movements, such as walking. The purpose of this study is to develop a methodology for quantifying excessive movement of the fibula bone relative to the tibia bone in traditional below the knee amputations. The methodology will measure the movement and rotation of the fibula relative to the tibia. These results can be compared to the bone movement from below the knee distal tibiofibular fusion procedure in order to observe if the excessive movement has been reduced. Matlab was used to analyze CT data from a traditional transtibial amputation subject and a distal tibiofibular fusion subject under four loading conditions. Distance and rotation measurements were collected using preexisting and generated Matlab programs. The measurements include locations from several regions on the limb to try to establish a trend for motion. A repeatable methodology with high precision was developed to quantify the movement of the fibula relative to the tibia for both distance and rotation measurements; the average standard deviation for distance measurement is 0.374 mm and the average standard deviation for rotation measurement is 0.131 degrees."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.64","2.12 MB"]},{"key":"dc:title","label":"Title","values":["Methodology for Quantifying Biomechanical Bone Movement of Transtibial Amputations"]}]}],"canonical_facts":{"dc:contributor":["He, Ping","Reynolds, David"],"dc:creator":["Bell, Johanna C."],"dc:date":["2006"],"dc:description":["A controversy has long existed about an alternate below knee amputation procedure that may be more beneficial than the traditional transtibial amputation. The proponents of this alternate procedure that stabilizes the distal tibia and fibula claim it reduces excessive movement of the fibula relative to the tibia that occurs with common movements, such as walking. The purpose of this study is to develop a methodology for quantifying excessive movement of the fibula bone relative to the tibia bone in traditional below the knee amputations. The methodology will measure the movement and rotation of the fibula relative to the tibia. These results can be compared to the bone movement from below the knee distal tibiofibular fusion procedure in order to observe if the excessive movement has been reduced. Matlab was used to analyze CT data from a traditional transtibial amputation subject and a distal tibiofibular fusion subject under four loading conditions. Distance and rotation measurements were collected using preexisting and generated Matlab programs. The measurements include locations from several regions on the limb to try to establish a trend for motion. A repeatable methodology with high precision was developed to quantify the movement of the fibula relative to the tibia for both distance and rotation measurements; the average standard deviation for distance measurement is 0.374 mm and the average standard deviation for rotation measurement is 0.131 degrees."],"dc:format":["application/pdf","p.64","2.12 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1166490962"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering, Biomedical","tibia","fibula","limb","loading conditions","Amputations","Bone"],"dc:title":["Methodology for Quantifying Biomechanical Bone Movement of Transtibial Amputations"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:31:29Z"}