{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1210371947"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1210371947","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A System for Collecting Data to Characterize a Pre-Fall Change in Sway: Development and Proof-of-Concept Analyses","abstract":"Falls account for almost two million emergency department visits per year in the U.S. and are the leading cause of injury deaths among adults 65 years of age and older. Despite efforts to reduce fall risk factors, about one-third of community-dwelling older adults fall each year in the U.S. New methods and devices are needed to prevent falls and to reduce morbidity and mortality related to falls. Presently, it is unknown if there is a measurable change in sway before a person falls. In order to find out, a wireless data acquisition system was developed as no existing tools were available. A fall was induced to allow the study of pre-fall motion on a healthy subject. The sensor was positioned at the level of the hips, upper torso, shoulder, and head. The data collected showed a measureable change in postural motion. The results indicated that there are four distinguishable levels of postural stability, which are baseline, near-fall, pre-fall, and fall. Also, the hip level is the optimal sensor location based on the results of this pilot study. This research serves as a basis for further work in postural sway and interventions to prevent falls.","abstract_html":"Falls account for almost two million emergency department visits per year in the U.S. and are the leading cause of injury deaths among adults 65 years of age and older. Despite efforts to reduce fall risk factors, about one-third of community-dwelling older adults fall each year in the U.S. New methods and devices are needed to prevent falls and to reduce morbidity and mortality related to falls. Presently, it is unknown if there is a measurable change in sway before a person falls. In order to find out, a wireless data acquisition system was developed as no existing tools were available. A fall was induced to allow the study of pre-fall motion on a healthy subject. The sensor was positioned at the level of the hips, upper torso, shoulder, and head. The data collected showed a measureable change in postural motion. The results indicated that there are four distinguishable levels of postural stability, which are baseline, near-fall, pre-fall, and fall. Also, the hip level is the optimal sensor location based on the results of this pilot study. This research serves as a basis for further work in postural sway and interventions to prevent falls.","abstract_has_math":false,"creators":["Sipp, Amy Renae"],"institution":"Wright State University","degree_name":"Doctor of Philosophy (PhD)","degree_level":"doctoral","degree_discipline":"Engineering PhD","degree_department":null,"school":null,"contributors":[],"advisors":["Rowley, Blair","Reynolds, David"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-05-12","date_published":"2008-05-12","updated_at":"2026-11-27T04:38:26Z","subjects":["Biomedical Research","Electrical Engineering","Remote Sensing","falling","gyroscope","wireless data acquisition system","motion detection"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1210371947","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1210371947","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1210371947","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1210371947","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rowley, Blair","Reynolds, David"]},{"key":"dc:creator","label":"Author","values":["Sipp, Amy Renae"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-05-12"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering PhD"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Electrical Engineering","Remote Sensing","falling","gyroscope","wireless data acquisition system","motion detection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1210371947"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Falls account for almost two million emergency department visits per year in the U.S. and are the leading cause of injury deaths among adults 65 years of age and older. Despite efforts to reduce fall risk factors, about one-third of community-dwelling older adults fall each year in the U.S. New methods and devices are needed to prevent falls and to reduce morbidity and mortality related to falls. Presently, it is unknown if there is a measurable change in sway before a person falls. In order to find out, a wireless data acquisition system was developed as no existing tools were available. A fall was induced to allow the study of pre-fall motion on a healthy subject. The sensor was positioned at the level of the hips, upper torso, shoulder, and head. The data collected showed a measureable change in postural motion. The results indicated that there are four distinguishable levels of postural stability, which are baseline, near-fall, pre-fall, and fall. Also, the hip level is the optimal sensor location based on the results of this pilot study. This research serves as a basis for further work in postural sway and interventions to prevent falls."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.540","40.43 MB"]},{"key":"dc:title","label":"Title","values":["A System for Collecting Data to Characterize a Pre-Fall Change in Sway: Development and Proof-of-Concept Analyses"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rowley, Blair","Reynolds, David"],"dc:creator":["Sipp, Amy Renae"],"dc:date":["2008-05-12"],"dc:description":["Falls account for almost two million emergency department visits per year in the U.S. and are the leading cause of injury deaths among adults 65 years of age and older. Despite efforts to reduce fall risk factors, about one-third of community-dwelling older adults fall each year in the U.S. New methods and devices are needed to prevent falls and to reduce morbidity and mortality related to falls. Presently, it is unknown if there is a measurable change in sway before a person falls. In order to find out, a wireless data acquisition system was developed as no existing tools were available. A fall was induced to allow the study of pre-fall motion on a healthy subject. The sensor was positioned at the level of the hips, upper torso, shoulder, and head. The data collected showed a measureable change in postural motion. The results indicated that there are four distinguishable levels of postural stability, which are baseline, near-fall, pre-fall, and fall. Also, the hip level is the optimal sensor location based on the results of this pilot study. This research serves as a basis for further work in postural sway and interventions to prevent falls."],"dc:format":["application/pdf","p.540","40.43 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1210371947"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Electrical Engineering","Remote Sensing","falling","gyroscope","wireless data acquisition system","motion detection"],"dc:title":["A System for Collecting Data to Characterize a Pre-Fall Change in Sway: Development and Proof-of-Concept Analyses"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering PhD"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:38:26Z"}