{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1227233038"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1227233038","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Dynamic Characterization of a Pneumatic Muscle Actuator and Its Application to a Resistive Training Device","abstract":"<p>Research described in this dissertation expands the use of a biomechanical phenomenological model to a commercially available pneumatic muscle actuator (PMA). Due to the nonlinearities of the device, achieving accurate control is challenging. Experiments have been conducted that define boundaries of operation where linear approximations can be used to describe the dynamics of the PMA. Empirical data presented in this dissertation show that nonlinearities exist more prevalently at higher loads (on average >70% contractile force value). When the PMA is under high loads, low displacement occurs. Therefore, these regions are of less interest to design engineers. Once conditions of nonlinearities were defined, operational areas of interest were characterized. </p><p>Open-loop linear systems analysis utilized the characterization profiles for the PMA in combination with a model for the D.C. servo motor to develop a system transfer function describing the dynamics of the overall plant. A Tustin (bilinear) transform was applied to the transfer function to generate a discrete time recursion equation. This equation describes the interaction of the PMA and the D.C. servo motor. It was then used to generate motor voltage profiles to demonstrate various tasks on the system. </p><p>Finally, this dissertation describes a new concept of using PMAs as an antagonist in a resistive training device. One such application is in a microgravity environment (prolonged space flight). The characterization analysis presents a method to demonstrate this task on the Dynamic Test Station (DTS). In this demonstration the PMA acts as an antagonist generating a resistive load, which the D.C. servo motor, representing the human operator, works against. A 90 degree isokinetic (constant velocity) rotation of the D.C. servo motor pulley is achieved at eight PMA pressures each of which generates a different resistive load.</p>","abstract_html":"&lt;p&gt;Research described in this dissertation expands the use of a biomechanical phenomenological model to a commercially available pneumatic muscle actuator (PMA). Due to the nonlinearities of the device, achieving accurate control is challenging. Experiments have been conducted that define boundaries of operation where linear approximations can be used to describe the dynamics of the PMA. Empirical data presented in this dissertation show that nonlinearities exist more prevalently at higher loads (on average &gt;70% contractile force value). When the PMA is under high loads, low displacement occurs. Therefore, these regions are of less interest to design engineers. Once conditions of nonlinearities were defined, operational areas of interest were characterized. &lt;/p&gt;&lt;p&gt;Open-loop linear systems analysis utilized the characterization profiles for the PMA in combination with a model for the D.C. servo motor to develop a system transfer function describing the dynamics of the overall plant. A Tustin (bilinear) transform was applied to the transfer function to generate a discrete time recursion equation. This equation describes the interaction of the PMA and the D.C. servo motor. It was then used to generate motor voltage profiles to demonstrate various tasks on the system. &lt;/p&gt;&lt;p&gt;Finally, this dissertation describes a new concept of using PMAs as an antagonist in a resistive training device. One such application is in a microgravity environment (prolonged space flight). The characterization analysis presents a method to demonstrate this task on the Dynamic Test Station (DTS). In this demonstration the PMA acts as an antagonist generating a resistive load, which the D.C. servo motor, representing the human operator, works against. A 90 degree isokinetic (constant velocity) rotation of the D.C. servo motor pulley is achieved at eight PMA pressures each of which generates a different resistive load.&lt;/p&gt;","abstract_has_math":false,"creators":["Serres, Jennifer L."],"institution":"Wright State University","degree_name":"Doctor of Philosophy (PhD)","degree_level":"doctoral","degree_discipline":"Engineering PhD","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Reynolds, David B.","Phillips, Chandler A."],"committee_members":[],"year":2008,"date_issued":"2008-11-21","date_published":"2008-11-21","updated_at":"2026-11-27T04:38:26Z","subjects":["Biomedical Research","Pneumatic Muscle Actuator","Phenomenological Model","biomimetic","parameter characterization","zero-G exercise","resistive training device"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1227233038","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1227233038","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1227233038","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1227233038","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Reynolds, David B.","Phillips, Chandler A."]},{"key":"dc:creator","label":"Author","values":["Serres, Jennifer L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2008-11-21"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering PhD"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Pneumatic Muscle Actuator","Phenomenological Model","biomimetic","parameter characterization","zero-G exercise","resistive training device"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1227233038"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Research described in this dissertation expands the use of a biomechanical phenomenological model to a commercially available pneumatic muscle actuator (PMA). Due to the nonlinearities of the device, achieving accurate control is challenging. Experiments have been conducted that define boundaries of operation where linear approximations can be used to describe the dynamics of the PMA. Empirical data presented in this dissertation show that nonlinearities exist more prevalently at higher loads (on average >70% contractile force value). When the PMA is under high loads, low displacement occurs. Therefore, these regions are of less interest to design engineers. Once conditions of nonlinearities were defined, operational areas of interest were characterized. </p><p>Open-loop linear systems analysis utilized the characterization profiles for the PMA in combination with a model for the D.C. servo motor to develop a system transfer function describing the dynamics of the overall plant. A Tustin (bilinear) transform was applied to the transfer function to generate a discrete time recursion equation. This equation describes the interaction of the PMA and the D.C. servo motor. It was then used to generate motor voltage profiles to demonstrate various tasks on the system. </p><p>Finally, this dissertation describes a new concept of using PMAs as an antagonist in a resistive training device. One such application is in a microgravity environment (prolonged space flight). The characterization analysis presents a method to demonstrate this task on the Dynamic Test Station (DTS). In this demonstration the PMA acts as an antagonist generating a resistive load, which the D.C. servo motor, representing the human operator, works against. A 90 degree isokinetic (constant velocity) rotation of the D.C. servo motor pulley is achieved at eight PMA pressures each of which generates a different resistive load.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.218","8.64 MB"]},{"key":"dc:title","label":"Title","values":["Dynamic Characterization of a Pneumatic Muscle Actuator and Its Application to a Resistive Training Device"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Reynolds, David B.","Phillips, Chandler A."],"dc:creator":["Serres, Jennifer L."],"dc:date":["2008-11-21"],"dc:description":["<p>Research described in this dissertation expands the use of a biomechanical phenomenological model to a commercially available pneumatic muscle actuator (PMA). Due to the nonlinearities of the device, achieving accurate control is challenging. Experiments have been conducted that define boundaries of operation where linear approximations can be used to describe the dynamics of the PMA. Empirical data presented in this dissertation show that nonlinearities exist more prevalently at higher loads (on average >70% contractile force value). When the PMA is under high loads, low displacement occurs. Therefore, these regions are of less interest to design engineers. Once conditions of nonlinearities were defined, operational areas of interest were characterized. </p><p>Open-loop linear systems analysis utilized the characterization profiles for the PMA in combination with a model for the D.C. servo motor to develop a system transfer function describing the dynamics of the overall plant. A Tustin (bilinear) transform was applied to the transfer function to generate a discrete time recursion equation. This equation describes the interaction of the PMA and the D.C. servo motor. It was then used to generate motor voltage profiles to demonstrate various tasks on the system. </p><p>Finally, this dissertation describes a new concept of using PMAs as an antagonist in a resistive training device. One such application is in a microgravity environment (prolonged space flight). The characterization analysis presents a method to demonstrate this task on the Dynamic Test Station (DTS). In this demonstration the PMA acts as an antagonist generating a resistive load, which the D.C. servo motor, representing the human operator, works against. A 90 degree isokinetic (constant velocity) rotation of the D.C. servo motor pulley is achieved at eight PMA pressures each of which generates a different resistive load.</p>"],"dc:format":["application/pdf","p.218","8.64 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1227233038"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Pneumatic Muscle Actuator","Phenomenological Model","biomimetic","parameter characterization","zero-G exercise","resistive training device"],"dc:title":["Dynamic Characterization of a Pneumatic Muscle Actuator and Its Application to a Resistive Training Device"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Engineering PhD"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:38:26Z"}