{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1245155890"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1245155890","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Effect of Variable Gravity on the Cooling Performance of a Partially-Confined FC-72 Spray","abstract":"This thesis discusses the effects of a variable-gravity environment on the performance of a subcooled partially-confined spray. An experiment, consisting of a test chamber, the associated flow loops, and instrumentation, was fabricated and flown on the NASA Reduced-Gravity Testing Platform. This modified KC-135 aircraft followed a parabolic flight path to provide various acceleration levels. The spray chamber contained two opposing nozzles spraying onto Thick Film Resistor (TFR) heaters, which were mounted on insulating glass pedestals. Only the upward facing heater was used during this testing. Thermocouples under the heater in the glass pedestal were used to determine the heater surface temperature. The glass pedestals were surrounded by an annular sump system, which was used to collect and remove the cooling fluid from the test chamber. The fluid used for this testing was FC-72, which is a non-toxic, non-flammable, and non-reactive refrigerant. Due to its dielectric nature, FC-72 was sprayed directly onto the electric thick film heaters. The parametric ranges of this experiment were as follows: Heat flux to the spray, 21.1 ≤ <i>q</i>″<sub>sp</sub> ≤ 69.0 W/cm<sup>2</sup>; acceleration field, 0.15 ≤ <i>a</i> ≤ 1.80 g; coolant volumetric flow rate, 6.18 ≤ <i>V</i> ≤ 8.94 ml/s; and coolant subcooling, 23.1 ≤ Δ<i>T</i><sub>sc</sub> ≤ 31.7 K. The heat fluxes tested were below the critical heat flux <i>q</i>″<sub>CHF</sub>. The wall superheat Δ<i>T</i><sub>sat</sub> = <i>T</i><sub>s</sub> − <i>T</i><sub>sat</sub> was found to increase with heat input and acceleration, and decrease with subcooling and volumetric flow rate.","abstract_html":"This thesis discusses the effects of a variable-gravity environment on the performance of a subcooled partially-confined spray. An experiment, consisting of a test chamber, the associated flow loops, and instrumentation, was fabricated and flown on the NASA Reduced-Gravity Testing Platform. This modified KC-135 aircraft followed a parabolic flight path to provide various acceleration levels. The spray chamber contained two opposing nozzles spraying onto Thick Film Resistor (TFR) heaters, which were mounted on insulating glass pedestals. Only the upward facing heater was used during this testing. Thermocouples under the heater in the glass pedestal were used to determine the heater surface temperature. The glass pedestals were surrounded by an annular sump system, which was used to collect and remove the cooling fluid from the test chamber. The fluid used for this testing was FC-72, which is a non-toxic, non-flammable, and non-reactive refrigerant. Due to its dielectric nature, FC-72 was sprayed directly onto the electric thick film heaters. The parametric ranges of this experiment were as follows: Heat flux to the spray, 21.1 ≤ &lt;i&gt;q&lt;/i&gt;″&lt;sub&gt;sp&lt;/sub&gt; ≤ 69.0 W/cm&lt;sup&gt;2&lt;/sup&gt;; acceleration field, 0.15 ≤ &lt;i&gt;a&lt;/i&gt; ≤ 1.80 g; coolant volumetric flow rate, 6.18 ≤ &lt;i&gt;V&lt;/i&gt; ≤ 8.94 ml/s; and coolant subcooling, 23.1 ≤ Δ&lt;i&gt;T&lt;/i&gt;&lt;sub&gt;sc&lt;/sub&gt; ≤ 31.7 K. The heat fluxes tested were below the critical heat flux &lt;i&gt;q&lt;/i&gt;″&lt;sub&gt;CHF&lt;/sub&gt;. The wall superheat Δ&lt;i&gt;T&lt;/i&gt;&lt;sub&gt;sat&lt;/sub&gt; = &lt;i&gt;T&lt;/i&gt;&lt;sub&gt;s&lt;/sub&gt; − &lt;i&gt;T&lt;/i&gt;&lt;sub&gt;sat&lt;/sub&gt; was found to increase with heat input and acceleration, and decrease with subcooling and volumetric flow rate.","abstract_has_math":false,"creators":["Michalak, Travis Edward"],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Thomas, Scott K."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-06-29","date_published":"2009-06-29","updated_at":"2026-11-26T04:31:56Z","subjects":["Mechanical Engineering","spray cooling","acceleration","variable gravity","thermal management"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1245155890","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1245155890","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1245155890","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1245155890","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Thomas, Scott K."]},{"key":"dc:creator","label":"Author","values":["Michalak, Travis Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-06-29"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering","spray cooling","acceleration","variable gravity","thermal management"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1245155890"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis discusses the effects of a variable-gravity environment on the performance of a subcooled partially-confined spray. An experiment, consisting of a test chamber, the associated flow loops, and instrumentation, was fabricated and flown on the NASA Reduced-Gravity Testing Platform. This modified KC-135 aircraft followed a parabolic flight path to provide various acceleration levels. The spray chamber contained two opposing nozzles spraying onto Thick Film Resistor (TFR) heaters, which were mounted on insulating glass pedestals. Only the upward facing heater was used during this testing. Thermocouples under the heater in the glass pedestal were used to determine the heater surface temperature. The glass pedestals were surrounded by an annular sump system, which was used to collect and remove the cooling fluid from the test chamber. The fluid used for this testing was FC-72, which is a non-toxic, non-flammable, and non-reactive refrigerant. Due to its dielectric nature, FC-72 was sprayed directly onto the electric thick film heaters. The parametric ranges of this experiment were as follows: Heat flux to the spray, 21.1 ≤ <i>q</i>″<sub>sp</sub> ≤ 69.0 W/cm<sup>2</sup>; acceleration field, 0.15 ≤ <i>a</i> ≤ 1.80 g; coolant volumetric flow rate, 6.18 ≤ <i>V</i> ≤ 8.94 ml/s; and coolant subcooling, 23.1 ≤ Δ<i>T</i><sub>sc</sub> ≤ 31.7 K. The heat fluxes tested were below the critical heat flux <i>q</i>″<sub>CHF</sub>. The wall superheat Δ<i>T</i><sub>sat</sub> = <i>T</i><sub>s</sub> − <i>T</i><sub>sat</sub> was found to increase with heat input and acceleration, and decrease with subcooling and volumetric flow rate."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.224","6.84 MB"]},{"key":"dc:title","label":"Title","values":["The Effect of Variable Gravity on the Cooling Performance of a Partially-Confined FC-72 Spray"]}]}],"canonical_facts":{"dc:contributor":["Thomas, Scott K."],"dc:creator":["Michalak, Travis Edward"],"dc:date":["2009-06-29"],"dc:description":["This thesis discusses the effects of a variable-gravity environment on the performance of a subcooled partially-confined spray. An experiment, consisting of a test chamber, the associated flow loops, and instrumentation, was fabricated and flown on the NASA Reduced-Gravity Testing Platform. This modified KC-135 aircraft followed a parabolic flight path to provide various acceleration levels. The spray chamber contained two opposing nozzles spraying onto Thick Film Resistor (TFR) heaters, which were mounted on insulating glass pedestals. Only the upward facing heater was used during this testing. Thermocouples under the heater in the glass pedestal were used to determine the heater surface temperature. The glass pedestals were surrounded by an annular sump system, which was used to collect and remove the cooling fluid from the test chamber. The fluid used for this testing was FC-72, which is a non-toxic, non-flammable, and non-reactive refrigerant. Due to its dielectric nature, FC-72 was sprayed directly onto the electric thick film heaters. The parametric ranges of this experiment were as follows: Heat flux to the spray, 21.1 ≤ <i>q</i>″<sub>sp</sub> ≤ 69.0 W/cm<sup>2</sup>; acceleration field, 0.15 ≤ <i>a</i> ≤ 1.80 g; coolant volumetric flow rate, 6.18 ≤ <i>V</i> ≤ 8.94 ml/s; and coolant subcooling, 23.1 ≤ Δ<i>T</i><sub>sc</sub> ≤ 31.7 K. The heat fluxes tested were below the critical heat flux <i>q</i>″<sub>CHF</sub>. The wall superheat Δ<i>T</i><sub>sat</sub> = <i>T</i><sub>s</sub> − <i>T</i><sub>sat</sub> was found to increase with heat input and acceleration, and decrease with subcooling and volumetric flow rate."],"dc:format":["application/pdf","p.224","6.84 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1245155890"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Mechanical Engineering","spray cooling","acceleration","variable gravity","thermal management"],"dc:title":["The Effect of Variable Gravity on the Cooling Performance of a Partially-Confined FC-72 Spray"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:31:56Z"}