{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1271111941"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1271111941","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Harmonic Distortion Reduction of Phase-Angle Fired SCRs Feeding a Resistive Load using Fuzzy Logic","abstract":"High power silicon controlled rectifiers (SCR) are used in the application of infraredradiation testing. A case study has been performed on a department of defense facilityutilizing SCRs to transfer electrical energy to thermal energy. The facility is capable ofgenerating up to 5000 °F across large cross-sectional areas, requiring tens of megawattsof power. The combination of high power, unbalanced loads, and SCR switching generatehigh harmonic disturbances that offer significant challenges for conventional linearcontrol systems. In addition, unbalanced three-phase distribution systems are difficult tomodel, specifically during switching transients. Fuzzy logic is used to characterize thenon-linear plant dynamics, control the system output, and reduce harmonics. Although theuse of fuzzy logic for harmonic reduction has been used extensively in the power industry,most applications focus on compensating for harmonic disturbance rather than avoiding it.Harmonic compensation adds hardware in the system, which adds maintenance costs andinefficiency. This thesis introduces a technique to eliminate harmonic content in the controlloop without adding additional hardware. A simulation of the system was created andfuzzy logic was used to characterize the behavior of the simulation. The simulation resultsdemonstrated the non-linear control problem and identified key harmonic areas to avoid.A fuzzy proportional-integral controller along with a fuzzy harmonic reduction controlleris implemented in this thesis to improve the control response while avoiding harmful harmonicinterference. The fuzzy harmonic reduction controller yielded a hybrid pulse widthmodulation output that eliminated the most harmful harmonics while maintaining closedloop control.","abstract_html":"High power silicon controlled rectifiers (SCR) are used in the application of infraredradiation testing. A case study has been performed on a department of defense facilityutilizing SCRs to transfer electrical energy to thermal energy. The facility is capable ofgenerating up to 5000 °F across large cross-sectional areas, requiring tens of megawattsof power. The combination of high power, unbalanced loads, and SCR switching generatehigh harmonic disturbances that offer significant challenges for conventional linearcontrol systems. In addition, unbalanced three-phase distribution systems are difficult tomodel, specifically during switching transients. Fuzzy logic is used to characterize thenon-linear plant dynamics, control the system output, and reduce harmonics. Although theuse of fuzzy logic for harmonic reduction has been used extensively in the power industry,most applications focus on compensating for harmonic disturbance rather than avoiding it.Harmonic compensation adds hardware in the system, which adds maintenance costs andinefficiency. This thesis introduces a technique to eliminate harmonic content in the controlloop without adding additional hardware. A simulation of the system was created andfuzzy logic was used to characterize the behavior of the simulation. The simulation resultsdemonstrated the non-linear control problem and identified key harmonic areas to avoid.A fuzzy proportional-integral controller along with a fuzzy harmonic reduction controlleris implemented in this thesis to improve the control response while avoiding harmful harmonicinterference. The fuzzy harmonic reduction controller yielded a hybrid pulse widthmodulation output that eliminated the most harmful harmonics while maintaining closedloop control.","abstract_has_math":false,"creators":["Clark, Matthew A."],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Rattan, Kuldip"],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-04-15","date_published":"2010-04-15","updated_at":"2026-11-27T04:38:30Z","subjects":["Electrical Engineering","Fuzzy Logic","Control","Power","SCR","Harmonics","Substations"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1271111941","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1271111941","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1271111941","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1271111941","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rattan, Kuldip"]},{"key":"dc:creator","label":"Author","values":["Clark, Matthew A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-04-15"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering","Fuzzy Logic","Control","Power","SCR","Harmonics","Substations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1271111941"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["High power silicon controlled rectifiers (SCR) are used in the application of infraredradiation testing. A case study has been performed on a department of defense facilityutilizing SCRs to transfer electrical energy to thermal energy. The facility is capable ofgenerating up to 5000 °F across large cross-sectional areas, requiring tens of megawattsof power. The combination of high power, unbalanced loads, and SCR switching generatehigh harmonic disturbances that offer significant challenges for conventional linearcontrol systems. In addition, unbalanced three-phase distribution systems are difficult tomodel, specifically during switching transients. Fuzzy logic is used to characterize thenon-linear plant dynamics, control the system output, and reduce harmonics. Although theuse of fuzzy logic for harmonic reduction has been used extensively in the power industry,most applications focus on compensating for harmonic disturbance rather than avoiding it.Harmonic compensation adds hardware in the system, which adds maintenance costs andinefficiency. This thesis introduces a technique to eliminate harmonic content in the controlloop without adding additional hardware. A simulation of the system was created andfuzzy logic was used to characterize the behavior of the simulation. The simulation resultsdemonstrated the non-linear control problem and identified key harmonic areas to avoid.A fuzzy proportional-integral controller along with a fuzzy harmonic reduction controlleris implemented in this thesis to improve the control response while avoiding harmful harmonicinterference. The fuzzy harmonic reduction controller yielded a hybrid pulse widthmodulation output that eliminated the most harmful harmonics while maintaining closedloop control."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.99","2.96 MB"]},{"key":"dc:title","label":"Title","values":["The Harmonic Distortion Reduction of Phase-Angle Fired SCRs Feeding a Resistive Load using Fuzzy Logic"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rattan, Kuldip"],"dc:creator":["Clark, Matthew A."],"dc:date":["2010-04-15"],"dc:description":["High power silicon controlled rectifiers (SCR) are used in the application of infraredradiation testing. A case study has been performed on a department of defense facilityutilizing SCRs to transfer electrical energy to thermal energy. The facility is capable ofgenerating up to 5000 °F across large cross-sectional areas, requiring tens of megawattsof power. The combination of high power, unbalanced loads, and SCR switching generatehigh harmonic disturbances that offer significant challenges for conventional linearcontrol systems. In addition, unbalanced three-phase distribution systems are difficult tomodel, specifically during switching transients. Fuzzy logic is used to characterize thenon-linear plant dynamics, control the system output, and reduce harmonics. Although theuse of fuzzy logic for harmonic reduction has been used extensively in the power industry,most applications focus on compensating for harmonic disturbance rather than avoiding it.Harmonic compensation adds hardware in the system, which adds maintenance costs andinefficiency. This thesis introduces a technique to eliminate harmonic content in the controlloop without adding additional hardware. A simulation of the system was created andfuzzy logic was used to characterize the behavior of the simulation. The simulation resultsdemonstrated the non-linear control problem and identified key harmonic areas to avoid.A fuzzy proportional-integral controller along with a fuzzy harmonic reduction controlleris implemented in this thesis to improve the control response while avoiding harmful harmonicinterference. The fuzzy harmonic reduction controller yielded a hybrid pulse widthmodulation output that eliminated the most harmful harmonics while maintaining closedloop control."],"dc:format":["application/pdf","p.99","2.96 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1271111941"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Electrical Engineering","Fuzzy Logic","Control","Power","SCR","Harmonics","Substations"],"dc:title":["The Harmonic Distortion Reduction of Phase-Angle Fired SCRs Feeding a Resistive Load using Fuzzy Logic"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:38:30Z"}