{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1271689072"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1271689072","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Population Fit Threshold: Fully Automated Signal Map generation for Baseline Correction in NMR-based Metabolomics","abstract":"Baseline correction of NMR-based metabolomic spectra is a key step in data processing to elucidate biomarkers of diseased and toxic states. Automated baseline correction methods often use human-selected parameters. Presented is a method for automated baseline correction using parameters selected from and without manipulation of the spectrum. The focus is on generating an accurate signal map based on the differentiating characteristics of baseline noise and signal. The presented method of signal map generation and baseline correction was developed and tested on 13C and 1H NMR spectra. The spectra were as simple as chemical standards containing less than 25 signal peaks to very dense urinary metabolite profiles. This method has shown proper correction of even the most complicated NMR biofluid spectra and is acceptable for use in multivariate analyses. This technique may also be robust enough to utilize in other spectroscopic methods in which thermally generated baseline noise is present.","abstract_html":"Baseline correction of NMR-based metabolomic spectra is a key step in data processing to elucidate biomarkers of diseased and toxic states. Automated baseline correction methods often use human-selected parameters. Presented is a method for automated baseline correction using parameters selected from and without manipulation of the spectrum. The focus is on generating an accurate signal map based on the differentiating characteristics of baseline noise and signal. The presented method of signal map generation and baseline correction was developed and tested on 13C and 1H NMR spectra. The spectra were as simple as chemical standards containing less than 25 signal peaks to very dense urinary metabolite profiles. This method has shown proper correction of even the most complicated NMR biofluid spectra and is acceptable for use in multivariate analyses. This technique may also be robust enough to utilize in other spectroscopic methods in which thermally generated baseline noise is present.","abstract_has_math":false,"creators":["Homer, Daniel C."],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Reo, Nicholas","Skipper, Julie"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-05-14","date_published":"2010-05-14","updated_at":"2026-11-26T04:32:10Z","subjects":["Bioinformatics","Computer Science","Engineering","NMR","Metabolomics","Baseline Correction: Signal Map","Spectroscopy"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1271689072","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1271689072","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1271689072","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1271689072","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Reo, Nicholas","Skipper, Julie"]},{"key":"dc:creator","label":"Author","values":["Homer, Daniel C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-05-14"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bioinformatics","Computer Science","Engineering","NMR","Metabolomics","Baseline Correction: Signal Map","Spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1271689072"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Baseline correction of NMR-based metabolomic spectra is a key step in data processing to elucidate biomarkers of diseased and toxic states. Automated baseline correction methods often use human-selected parameters. Presented is a method for automated baseline correction using parameters selected from and without manipulation of the spectrum. The focus is on generating an accurate signal map based on the differentiating characteristics of baseline noise and signal. The presented method of signal map generation and baseline correction was developed and tested on 13C and 1H NMR spectra. The spectra were as simple as chemical standards containing less than 25 signal peaks to very dense urinary metabolite profiles. This method has shown proper correction of even the most complicated NMR biofluid spectra and is acceptable for use in multivariate analyses. This technique may also be robust enough to utilize in other spectroscopic methods in which thermally generated baseline noise is present."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.69","923.8 KB"]},{"key":"dc:title","label":"Title","values":["Population Fit Threshold: Fully Automated Signal Map generation for Baseline Correction in NMR-based Metabolomics"]}]}],"canonical_facts":{"dc:contributor":["Reo, Nicholas","Skipper, Julie"],"dc:creator":["Homer, Daniel C."],"dc:date":["2010-05-14"],"dc:description":["Baseline correction of NMR-based metabolomic spectra is a key step in data processing to elucidate biomarkers of diseased and toxic states. Automated baseline correction methods often use human-selected parameters. Presented is a method for automated baseline correction using parameters selected from and without manipulation of the spectrum. The focus is on generating an accurate signal map based on the differentiating characteristics of baseline noise and signal. The presented method of signal map generation and baseline correction was developed and tested on 13C and 1H NMR spectra. The spectra were as simple as chemical standards containing less than 25 signal peaks to very dense urinary metabolite profiles. This method has shown proper correction of even the most complicated NMR biofluid spectra and is acceptable for use in multivariate analyses. This technique may also be robust enough to utilize in other spectroscopic methods in which thermally generated baseline noise is present."],"dc:format":["application/pdf","p.69","923.8 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1271689072"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Bioinformatics","Computer Science","Engineering","NMR","Metabolomics","Baseline Correction: Signal Map","Spectroscopy"],"dc:title":["Population Fit Threshold: Fully Automated Signal Map generation for Baseline Correction in NMR-based Metabolomics"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:10Z"}