{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1276484974"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1276484974","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"A Novel Synergistic Diagnosis Methodology for identifying Abnormalities in Wireless Capsule Endoscopy videos","abstract":"<p>Wireless Capsule Endoscopy (WCE) is a new technology that allows medical personnel to view the gastrointestinal (GI) mucosa. It is a swallowable miniature capsule device the size of a pill that transmits thousands of screenshots of the digestive tract to a wearable receiver. When the procedure finishes the video is uploaded to a workstation for viewing. Capsule Endoscopy has been established as a tool to identify various gastrointestinal (GI) conditions, such as blood-based abnormalities, polyps, ulcers, Crohn's disease in the small intestine, where the classical endoscopy is not regularly used.</p><p>As of 2009 the market is dominated by Given Imaging Inc. capsule (PillCam SB). More than 300,000 capsules have been sold since 2001 when it was first introduced. The company provides a software package (RAPID) to view the WCE video, offering a bleeding detector feature based on red color. It provides a position estimator of the capsule inside the digestive tract. Additionally its multi-view feature gives a simultaneous view of two or four consecutive video frames in multiple windows. Finally a library of reference images (RAPID Atlas) is provided so that the user can have easy access to on-screen case images. </p><p>Although the company's software is a useful tool, the viewing of a WCE video is still a time consuming process (~ 2 hours), even for experienced gastroenterologists. In addition, the company's software has serious limitations (35% bleeding detection) and no capability of detecting polyps or ulcers according to gastroenterologists. Therefore, the need for computer aided model-methodology with robust detection performance on various conditions (blood, polyps, ulcers, etc) is clearly obvious. </p><p>Thus, our research studies have been successfully carried out on: a) the automatic detection of malignant intestinal features like polyps, bleeding, and abnormal regions (tumors); b) finding the boundaries of the digestive organs; and c) reducing the viewing-examination time with a robust registra-tion methodology. These studies have led to the development of the ATRC Video Toolbox (ATRC-VT). </p><p>ATRC-VT incorporates signal processing methods, color and image processing techniques, and artificial intelligence tools to detect blood-based abnormalities, polyps and ulcers in the small intestine. It is the first computer aided detection (CAD) software with multiple capabilities for WCE videos designed with a Graphics User Interface so that it is easy to use.</p>","abstract_html":"&lt;p&gt;Wireless Capsule Endoscopy (WCE) is a new technology that allows medical personnel to view the gastrointestinal (GI) mucosa. It is a swallowable miniature capsule device the size of a pill that transmits thousands of screenshots of the digestive tract to a wearable receiver. When the procedure finishes the video is uploaded to a workstation for viewing. Capsule Endoscopy has been established as a tool to identify various gastrointestinal (GI) conditions, such as blood-based abnormalities, polyps, ulcers, Crohn&#x27;s disease in the small intestine, where the classical endoscopy is not regularly used.&lt;/p&gt;&lt;p&gt;As of 2009 the market is dominated by Given Imaging Inc. capsule (PillCam SB). More than 300,000 capsules have been sold since 2001 when it was first introduced. The company provides a software package (RAPID) to view the WCE video, offering a bleeding detector feature based on red color. It provides a position estimator of the capsule inside the digestive tract. Additionally its multi-view feature gives a simultaneous view of two or four consecutive video frames in multiple windows. Finally a library of reference images (RAPID Atlas) is provided so that the user can have easy access to on-screen case images. &lt;/p&gt;&lt;p&gt;Although the company&#x27;s software is a useful tool, the viewing of a WCE video is still a time consuming process (~ 2 hours), even for experienced gastroenterologists. In addition, the company&#x27;s software has serious limitations (35% bleeding detection) and no capability of detecting polyps or ulcers according to gastroenterologists. Therefore, the need for computer aided model-methodology with robust detection performance on various conditions (blood, polyps, ulcers, etc) is clearly obvious. &lt;/p&gt;&lt;p&gt;Thus, our research studies have been successfully carried out on: a) the automatic detection of malignant intestinal features like polyps, bleeding, and abnormal regions (tumors); b) finding the boundaries of the digestive organs; and c) reducing the viewing-examination time with a robust registra-tion methodology. These studies have led to the development of the ATRC Video Toolbox (ATRC-VT). &lt;/p&gt;&lt;p&gt;ATRC-VT incorporates signal processing methods, color and image processing techniques, and artificial intelligence tools to detect blood-based abnormalities, polyps and ulcers in the small intestine. It is the first computer aided detection (CAD) software with multiple capabilities for WCE videos designed with a Graphics User Interface so that it is easy to use.&lt;/p&gt;","abstract_has_math":false,"creators":["Karargyris, Alexandros"],"institution":"Wright State University","degree_name":"Doctor of Philosophy (PhD)","degree_level":"doctoral","degree_discipline":"Computer Science and Engineering PhD","degree_department":null,"school":null,"contributors":["Bourbakis, Nikolaos"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-07-21","date_published":"2010-07-21","updated_at":"2026-11-26T04:32:10Z","subjects":["Computer Science","capsule","endoscopy","imaging","medical","computer","graphics","computer vision","locomotion","bowel","digestive tract","gastroenterology"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1276484974","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1276484974","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1276484974","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1276484974","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bourbakis, Nikolaos"]},{"key":"dc:creator","label":"Author","values":["Karargyris, Alexandros"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-07-21"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer Science and Engineering PhD"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Computer Science","capsule","endoscopy","imaging","medical","computer","graphics","computer vision","locomotion","bowel","digestive tract","gastroenterology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1276484974"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Wireless Capsule Endoscopy (WCE) is a new technology that allows medical personnel to view the gastrointestinal (GI) mucosa. It is a swallowable miniature capsule device the size of a pill that transmits thousands of screenshots of the digestive tract to a wearable receiver. When the procedure finishes the video is uploaded to a workstation for viewing. Capsule Endoscopy has been established as a tool to identify various gastrointestinal (GI) conditions, such as blood-based abnormalities, polyps, ulcers, Crohn's disease in the small intestine, where the classical endoscopy is not regularly used.</p><p>As of 2009 the market is dominated by Given Imaging Inc. capsule (PillCam SB). More than 300,000 capsules have been sold since 2001 when it was first introduced. The company provides a software package (RAPID) to view the WCE video, offering a bleeding detector feature based on red color. It provides a position estimator of the capsule inside the digestive tract. Additionally its multi-view feature gives a simultaneous view of two or four consecutive video frames in multiple windows. Finally a library of reference images (RAPID Atlas) is provided so that the user can have easy access to on-screen case images. </p><p>Although the company's software is a useful tool, the viewing of a WCE video is still a time consuming process (~ 2 hours), even for experienced gastroenterologists. In addition, the company's software has serious limitations (35% bleeding detection) and no capability of detecting polyps or ulcers according to gastroenterologists. Therefore, the need for computer aided model-methodology with robust detection performance on various conditions (blood, polyps, ulcers, etc) is clearly obvious. </p><p>Thus, our research studies have been successfully carried out on: a) the automatic detection of malignant intestinal features like polyps, bleeding, and abnormal regions (tumors); b) finding the boundaries of the digestive organs; and c) reducing the viewing-examination time with a robust registra-tion methodology. These studies have led to the development of the ATRC Video Toolbox (ATRC-VT). </p><p>ATRC-VT incorporates signal processing methods, color and image processing techniques, and artificial intelligence tools to detect blood-based abnormalities, polyps and ulcers in the small intestine. It is the first computer aided detection (CAD) software with multiple capabilities for WCE videos designed with a Graphics User Interface so that it is easy to use.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.204","4.39 MB"]},{"key":"dc:title","label":"Title","values":["A Novel Synergistic Diagnosis Methodology for identifying Abnormalities in Wireless Capsule Endoscopy videos"]}]}],"canonical_facts":{"dc:contributor":["Bourbakis, Nikolaos"],"dc:creator":["Karargyris, Alexandros"],"dc:date":["2010-07-21"],"dc:description":["<p>Wireless Capsule Endoscopy (WCE) is a new technology that allows medical personnel to view the gastrointestinal (GI) mucosa. It is a swallowable miniature capsule device the size of a pill that transmits thousands of screenshots of the digestive tract to a wearable receiver. When the procedure finishes the video is uploaded to a workstation for viewing. Capsule Endoscopy has been established as a tool to identify various gastrointestinal (GI) conditions, such as blood-based abnormalities, polyps, ulcers, Crohn's disease in the small intestine, where the classical endoscopy is not regularly used.</p><p>As of 2009 the market is dominated by Given Imaging Inc. capsule (PillCam SB). More than 300,000 capsules have been sold since 2001 when it was first introduced. The company provides a software package (RAPID) to view the WCE video, offering a bleeding detector feature based on red color. It provides a position estimator of the capsule inside the digestive tract. Additionally its multi-view feature gives a simultaneous view of two or four consecutive video frames in multiple windows. Finally a library of reference images (RAPID Atlas) is provided so that the user can have easy access to on-screen case images. </p><p>Although the company's software is a useful tool, the viewing of a WCE video is still a time consuming process (~ 2 hours), even for experienced gastroenterologists. In addition, the company's software has serious limitations (35% bleeding detection) and no capability of detecting polyps or ulcers according to gastroenterologists. Therefore, the need for computer aided model-methodology with robust detection performance on various conditions (blood, polyps, ulcers, etc) is clearly obvious. </p><p>Thus, our research studies have been successfully carried out on: a) the automatic detection of malignant intestinal features like polyps, bleeding, and abnormal regions (tumors); b) finding the boundaries of the digestive organs; and c) reducing the viewing-examination time with a robust registra-tion methodology. These studies have led to the development of the ATRC Video Toolbox (ATRC-VT). </p><p>ATRC-VT incorporates signal processing methods, color and image processing techniques, and artificial intelligence tools to detect blood-based abnormalities, polyps and ulcers in the small intestine. It is the first computer aided detection (CAD) software with multiple capabilities for WCE videos designed with a Graphics User Interface so that it is easy to use.</p>"],"dc:format":["application/pdf","p.204","4.39 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1276484974"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Computer Science","capsule","endoscopy","imaging","medical","computer","graphics","computer vision","locomotion","bowel","digestive tract","gastroenterology"],"dc:title":["A Novel Synergistic Diagnosis Methodology for identifying Abnormalities in Wireless Capsule Endoscopy videos"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Computer Science and Engineering PhD"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:10Z"}