{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1282766380"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1282766380","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Finding Cadaveric Human Head Masses and Center of Gravity: A Comparison of Direct Measurement to 3D ing","abstract":"<p>Mass properties of the human head are critical elements in developing neck injury threshold criteria in acceleration and impact environments. In order to accurately simulate the dynamics of the head in impact and acceleration environments, valid mass properties data for the human head must exist. </p><p>The purpose of this study was two-fold: First, to directly measure and generate a useful data set of human head mass properties and anthropometry, and second, compare the results from the direct measurement to measurements obtained using computed tomographic (CT) analyses of the human head. Four cadaveric human heads, all male, were measured. </p><p>For the direct measurement procedure, each frozen specimen was secured in a lightweight-aluminum box. The mass, center of gravity (CG) and principal moments of inertia (MOI) were then measured. These same properties of the box alone were subtracted from the measured quantities to determine each specimen's mass properties. For the CT analysis, the identical specimen preparation was imaged with CT. With both slice collimation and table feed set at 1 mm, the CT image resolution was 0.284 mm3/voxel. Segmentation of tissue types based on density thresholds was used to divide the volumetric data into brain matter, bone, and fat/skin. Surfaces from these groups were extracted to create volumes representing these structures. Assigning mass densities to the segmented volumes, the mass properties of the head were calculated using MIMICS, a 3D ing program and results were compared.</p><p>The final results showed the method to be accurate. The average weight for the directly measured heads was 8.96 lb compared to 8.99 lb for the calculated. The average shift in the z-axis (CGz) for the directly measured heads was 0.91 in above the Frankfort origin while the measured shift was 1.00 in on average. Overall, there was no significant difference seen among any of the parameters at α = 0.05.</p>","abstract_html":"&lt;p&gt;Mass properties of the human head are critical elements in developing neck injury threshold criteria in acceleration and impact environments. In order to accurately simulate the dynamics of the head in impact and acceleration environments, valid mass properties data for the human head must exist. &lt;/p&gt;&lt;p&gt;The purpose of this study was two-fold: First, to directly measure and generate a useful data set of human head mass properties and anthropometry, and second, compare the results from the direct measurement to measurements obtained using computed tomographic (CT) analyses of the human head. Four cadaveric human heads, all male, were measured. &lt;/p&gt;&lt;p&gt;For the direct measurement procedure, each frozen specimen was secured in a lightweight-aluminum box. The mass, center of gravity (CG) and principal moments of inertia (MOI) were then measured. These same properties of the box alone were subtracted from the measured quantities to determine each specimen&#x27;s mass properties. For the CT analysis, the identical specimen preparation was imaged with CT. With both slice collimation and table feed set at 1 mm, the CT image resolution was 0.284 mm3/voxel. Segmentation of tissue types based on density thresholds was used to divide the volumetric data into brain matter, bone, and fat/skin. Surfaces from these groups were extracted to create volumes representing these structures. Assigning mass densities to the segmented volumes, the mass properties of the head were calculated using MIMICS, a 3D ing program and results were compared.&lt;/p&gt;&lt;p&gt;The final results showed the method to be accurate. The average weight for the directly measured heads was 8.96 lb compared to 8.99 lb for the calculated. The average shift in the z-axis (CGz) for the directly measured heads was 0.91 in above the Frankfort origin while the measured shift was 1.00 in on average. Overall, there was no significant difference seen among any of the parameters at α = 0.05.&lt;/p&gt;","abstract_has_math":false,"creators":["Roush, Grant Corwin"],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Reynolds, David"],"committee_members":[],"year":2010,"date_issued":"2010-10-27","date_published":"2010-10-27","updated_at":"2026-11-27T04:38:30Z","subjects":["Biomedical Research","Mass Properties","Imaging","Cadaver","Impact ing"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1282766380","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1282766380","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1282766380","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1282766380","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Reynolds, David"]},{"key":"dc:creator","label":"Author","values":["Roush, Grant Corwin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-10-27"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Mass Properties","Imaging","Cadaver","Impact ing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1282766380"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Mass properties of the human head are critical elements in developing neck injury threshold criteria in acceleration and impact environments. In order to accurately simulate the dynamics of the head in impact and acceleration environments, valid mass properties data for the human head must exist. </p><p>The purpose of this study was two-fold: First, to directly measure and generate a useful data set of human head mass properties and anthropometry, and second, compare the results from the direct measurement to measurements obtained using computed tomographic (CT) analyses of the human head. Four cadaveric human heads, all male, were measured. </p><p>For the direct measurement procedure, each frozen specimen was secured in a lightweight-aluminum box. The mass, center of gravity (CG) and principal moments of inertia (MOI) were then measured. These same properties of the box alone were subtracted from the measured quantities to determine each specimen's mass properties. For the CT analysis, the identical specimen preparation was imaged with CT. With both slice collimation and table feed set at 1 mm, the CT image resolution was 0.284 mm3/voxel. Segmentation of tissue types based on density thresholds was used to divide the volumetric data into brain matter, bone, and fat/skin. Surfaces from these groups were extracted to create volumes representing these structures. Assigning mass densities to the segmented volumes, the mass properties of the head were calculated using MIMICS, a 3D ing program and results were compared.</p><p>The final results showed the method to be accurate. The average weight for the directly measured heads was 8.96 lb compared to 8.99 lb for the calculated. The average shift in the z-axis (CGz) for the directly measured heads was 0.91 in above the Frankfort origin while the measured shift was 1.00 in on average. Overall, there was no significant difference seen among any of the parameters at α = 0.05.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.48","1009.1 KB"]},{"key":"dc:title","label":"Title","values":["Finding Cadaveric Human Head Masses and Center of Gravity: A Comparison of Direct Measurement to 3D ing"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Reynolds, David"],"dc:creator":["Roush, Grant Corwin"],"dc:date":["2010-10-27"],"dc:description":["<p>Mass properties of the human head are critical elements in developing neck injury threshold criteria in acceleration and impact environments. In order to accurately simulate the dynamics of the head in impact and acceleration environments, valid mass properties data for the human head must exist. </p><p>The purpose of this study was two-fold: First, to directly measure and generate a useful data set of human head mass properties and anthropometry, and second, compare the results from the direct measurement to measurements obtained using computed tomographic (CT) analyses of the human head. Four cadaveric human heads, all male, were measured. </p><p>For the direct measurement procedure, each frozen specimen was secured in a lightweight-aluminum box. The mass, center of gravity (CG) and principal moments of inertia (MOI) were then measured. These same properties of the box alone were subtracted from the measured quantities to determine each specimen's mass properties. For the CT analysis, the identical specimen preparation was imaged with CT. With both slice collimation and table feed set at 1 mm, the CT image resolution was 0.284 mm3/voxel. Segmentation of tissue types based on density thresholds was used to divide the volumetric data into brain matter, bone, and fat/skin. Surfaces from these groups were extracted to create volumes representing these structures. Assigning mass densities to the segmented volumes, the mass properties of the head were calculated using MIMICS, a 3D ing program and results were compared.</p><p>The final results showed the method to be accurate. The average weight for the directly measured heads was 8.96 lb compared to 8.99 lb for the calculated. The average shift in the z-axis (CGz) for the directly measured heads was 0.91 in above the Frankfort origin while the measured shift was 1.00 in on average. Overall, there was no significant difference seen among any of the parameters at α = 0.05.</p>"],"dc:format":["application/pdf","p.48","1009.1 KB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1282766380"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Mass Properties","Imaging","Cadaver","Impact ing"],"dc:title":["Finding Cadaveric Human Head Masses and Center of Gravity: A Comparison of Direct Measurement to 3D ing"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:38:30Z"}