{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1284726606"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1284726606","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Respiratory-Gated IMRT Quality Assurance with Motion in Two Dimensions","abstract":"<p>Intensity modulated radiation therapy (IMRT) plans can be furthercustomized to each patient with the use of a four-dimensional (4D) respiratorygatedcomputed tomography (CT), with time being the fourth dimension. The 4Drespiratory-gated CT allows for the internal margin (IM), the expansion of thetumor volume that accounts for physiologic motions, to be addressed in thetreatment planning process and no longer assumes that the treatments will bedelivered to a fixed or rigid patient anatomy. Delivering the IMRT plan with agated technique limits the treatment to a duty cycle when the target motion is at aminimum.</p><p>The goal of this project is to study respiratory-gated IMRT qualityassurance (QA) results for tumor motion in two dimensions and develop aguideline for acceptable limits on tumor motion and field size. Respiratory-gatedIMRT QA was performed for four field sizes and varying amounts of motion with afixed duty cycle using Sun Nuclear¿¿¿¿s MapCHECK and MotionSIM XY/4Dproducts. The treated and planned dose planes were compared and errors wereevaluated using standard acceptance conditions.</p>","abstract_html":"&lt;p&gt;Intensity modulated radiation therapy (IMRT) plans can be furthercustomized to each patient with the use of a four-dimensional (4D) respiratorygatedcomputed tomography (CT), with time being the fourth dimension. The 4Drespiratory-gated CT allows for the internal margin (IM), the expansion of thetumor volume that accounts for physiologic motions, to be addressed in thetreatment planning process and no longer assumes that the treatments will bedelivered to a fixed or rigid patient anatomy. Delivering the IMRT plan with agated technique limits the treatment to a duty cycle when the target motion is at aminimum.&lt;/p&gt;&lt;p&gt;The goal of this project is to study respiratory-gated IMRT qualityassurance (QA) results for tumor motion in two dimensions and develop aguideline for acceptable limits on tumor motion and field size. Respiratory-gatedIMRT QA was performed for four field sizes and varying amounts of motion with afixed duty cycle using Sun Nuclear¿¿¿¿s MapCHECK and MotionSIM XY/4Dproducts. The treated and planned dose planes were compared and errors wereevaluated using standard acceptance conditions.&lt;/p&gt;","abstract_has_math":false,"creators":["Massie, Michael Todd"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Foy, Brent"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-10-28","date_published":"2010-10-28","updated_at":"2026-11-26T04:32:10Z","subjects":["Physics","IMRT","QA","Respiratory-Gated","Intensity Modulated Radiation Therapy"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284726606","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284726606","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1284726606","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1284726606","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Foy, Brent"]},{"key":"dc:creator","label":"Author","values":["Massie, Michael Todd"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-10-28"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","IMRT","QA","Respiratory-Gated","Intensity Modulated Radiation Therapy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284726606"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Intensity modulated radiation therapy (IMRT) plans can be furthercustomized to each patient with the use of a four-dimensional (4D) respiratorygatedcomputed tomography (CT), with time being the fourth dimension. The 4Drespiratory-gated CT allows for the internal margin (IM), the expansion of thetumor volume that accounts for physiologic motions, to be addressed in thetreatment planning process and no longer assumes that the treatments will bedelivered to a fixed or rigid patient anatomy. Delivering the IMRT plan with agated technique limits the treatment to a duty cycle when the target motion is at aminimum.</p><p>The goal of this project is to study respiratory-gated IMRT qualityassurance (QA) results for tumor motion in two dimensions and develop aguideline for acceptable limits on tumor motion and field size. Respiratory-gatedIMRT QA was performed for four field sizes and varying amounts of motion with afixed duty cycle using Sun Nuclear¿¿¿¿s MapCHECK and MotionSIM XY/4Dproducts. The treated and planned dose planes were compared and errors wereevaluated using standard acceptance conditions.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.96","24.78 MB"]},{"key":"dc:title","label":"Title","values":["Respiratory-Gated IMRT Quality Assurance with Motion in Two Dimensions"]}]}],"canonical_facts":{"dc:contributor":["Foy, Brent"],"dc:creator":["Massie, Michael Todd"],"dc:date":["2010-10-28"],"dc:description":["<p>Intensity modulated radiation therapy (IMRT) plans can be furthercustomized to each patient with the use of a four-dimensional (4D) respiratorygatedcomputed tomography (CT), with time being the fourth dimension. The 4Drespiratory-gated CT allows for the internal margin (IM), the expansion of thetumor volume that accounts for physiologic motions, to be addressed in thetreatment planning process and no longer assumes that the treatments will bedelivered to a fixed or rigid patient anatomy. Delivering the IMRT plan with agated technique limits the treatment to a duty cycle when the target motion is at aminimum.</p><p>The goal of this project is to study respiratory-gated IMRT qualityassurance (QA) results for tumor motion in two dimensions and develop aguideline for acceptable limits on tumor motion and field size. Respiratory-gatedIMRT QA was performed for four field sizes and varying amounts of motion with afixed duty cycle using Sun Nuclear¿¿¿¿s MapCHECK and MotionSIM XY/4Dproducts. The treated and planned dose planes were compared and errors wereevaluated using standard acceptance conditions.</p>"],"dc:format":["application/pdf","p.96","24.78 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284726606"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics","IMRT","QA","Respiratory-Gated","Intensity Modulated Radiation Therapy"],"dc:title":["Respiratory-Gated IMRT Quality Assurance with Motion in Two Dimensions"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:10Z"}