{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1284754038"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1284754038","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Experimental Comparison of ACR and ICAMRL Magnetic Resonance Imaging Accreditation Protocols","abstract":"Two primary accrediting bodies exist for magnetic resonance imaging systems: the American College of Radiology (ACR) and the Intersocietal Commission for the Accreditation of Magnetic Resonance Laboratories (ICAMRL), each of which defines specific standards for specific image quality criteria at which MRI images must be produced. An MRI clinic that wishes to show a commitment to image quality may do so by becoming accredited by one of these organizations of their choosing. The limits of these image criteria were compared to demonstrate the standards of each accrediting body. Images were produced that fell well within the standards of both accrediting organization, and subsequent images were produced at the limits of ACR and ICAMRL standards respectively. These images were first produced using a phantom to quantify a difference in criteria standards, then images were produced using a human patient to show a qualitative difference in criteria standards for clinical applications.","abstract_html":"Two primary accrediting bodies exist for magnetic resonance imaging systems: the American College of Radiology (ACR) and the Intersocietal Commission for the Accreditation of Magnetic Resonance Laboratories (ICAMRL), each of which defines specific standards for specific image quality criteria at which MRI images must be produced. An MRI clinic that wishes to show a commitment to image quality may do so by becoming accredited by one of these organizations of their choosing. The limits of these image criteria were compared to demonstrate the standards of each accrediting body. Images were produced that fell well within the standards of both accrediting organization, and subsequent images were produced at the limits of ACR and ICAMRL standards respectively. These images were first produced using a phantom to quantify a difference in criteria standards, then images were produced using a human patient to show a qualitative difference in criteria standards for clinical applications.","abstract_has_math":false,"creators":["Prater, Brock Andrew"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Foy, Brent"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-10-28","date_published":"2010-10-28","updated_at":"2026-11-26T04:32:10Z","subjects":["Physics","Slice Thickness","Slice","ACR","ACCREDITATION","ICAMRL","Spatial Resolution","phantom"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284754038","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284754038","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1284754038","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1284754038","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Foy, Brent"]},{"key":"dc:creator","label":"Author","values":["Prater, Brock Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-10-28"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics","Slice Thickness","Slice","ACR","ACCREDITATION","ICAMRL","Spatial Resolution","phantom"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284754038"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Two primary accrediting bodies exist for magnetic resonance imaging systems: the American College of Radiology (ACR) and the Intersocietal Commission for the Accreditation of Magnetic Resonance Laboratories (ICAMRL), each of which defines specific standards for specific image quality criteria at which MRI images must be produced. An MRI clinic that wishes to show a commitment to image quality may do so by becoming accredited by one of these organizations of their choosing. The limits of these image criteria were compared to demonstrate the standards of each accrediting body. Images were produced that fell well within the standards of both accrediting organization, and subsequent images were produced at the limits of ACR and ICAMRL standards respectively. These images were first produced using a phantom to quantify a difference in criteria standards, then images were produced using a human patient to show a qualitative difference in criteria standards for clinical applications."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.97","3.61 MB"]},{"key":"dc:title","label":"Title","values":["Experimental Comparison of ACR and ICAMRL Magnetic Resonance Imaging Accreditation Protocols"]}]}],"canonical_facts":{"dc:contributor":["Foy, Brent"],"dc:creator":["Prater, Brock Andrew"],"dc:date":["2010-10-28"],"dc:description":["Two primary accrediting bodies exist for magnetic resonance imaging systems: the American College of Radiology (ACR) and the Intersocietal Commission for the Accreditation of Magnetic Resonance Laboratories (ICAMRL), each of which defines specific standards for specific image quality criteria at which MRI images must be produced. An MRI clinic that wishes to show a commitment to image quality may do so by becoming accredited by one of these organizations of their choosing. The limits of these image criteria were compared to demonstrate the standards of each accrediting body. Images were produced that fell well within the standards of both accrediting organization, and subsequent images were produced at the limits of ACR and ICAMRL standards respectively. These images were first produced using a phantom to quantify a difference in criteria standards, then images were produced using a human patient to show a qualitative difference in criteria standards for clinical applications."],"dc:format":["application/pdf","p.97","3.61 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284754038"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Physics","Slice Thickness","Slice","ACR","ACCREDITATION","ICAMRL","Spatial Resolution","phantom"],"dc:title":["Experimental Comparison of ACR and ICAMRL Magnetic Resonance Imaging Accreditation Protocols"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:10Z"}