{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1284785248"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1284785248","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"The Derivation and Testing of Three-Dimensional Line Equations That Predict the Location of Brachytherapy Sources","abstract":"In High Dose Rate brachytherapy, a catheter is placed inside the body and a radioactive source is allowed to dwell at specific positions to treat a tumor. In normal usage, anatomical images acquired before the treatment are used to plan dwell positions, and then the plan is executed without further verifying source locations during treatment. However, slight errors in catheter positioning and shifts in internal anatomy cause variations in source position. In this study, a general method for determining dwell positions during treatment is evaluated. For this method, the treatment source exposes the tumor to radiation and creates an image on a film after the radiation passes through a constructed phantom. 3D line reconstruction is then used to back-extrapolate to the source location. Experiments are performed for several types of catheter movement. Two methods of identifying image locations and two mathematical methods for back-extrapolation are evaluated.","abstract_html":"In High Dose Rate brachytherapy, a catheter is placed inside the body and a radioactive source is allowed to dwell at specific positions to treat a tumor. In normal usage, anatomical images acquired before the treatment are used to plan dwell positions, and then the plan is executed without further verifying source locations during treatment. However, slight errors in catheter positioning and shifts in internal anatomy cause variations in source position. In this study, a general method for determining dwell positions during treatment is evaluated. For this method, the treatment source exposes the tumor to radiation and creates an image on a film after the radiation passes through a constructed phantom. 3D line reconstruction is then used to back-extrapolate to the source location. Experiments are performed for several types of catheter movement. Two methods of identifying image locations and two mathematical methods for back-extrapolation are evaluated.","abstract_has_math":false,"creators":["Lindsey, Rhett Ellis"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Foy, Brent"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-10-28","date_published":"2010-10-28","updated_at":"2026-11-26T04:32:10Z","subjects":["Health","Health Care","Oncology","Physics","Public Health","Radiation","Radiology","Brachytherapy","Source Location","Medical Physics","Three-Dimensional Line Equation"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284785248","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284785248","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1284785248","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1284785248","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Foy, Brent"]},{"key":"dc:creator","label":"Author","values":["Lindsey, Rhett Ellis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-10-28"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health","Health Care","Oncology","Physics","Public Health","Radiation","Radiology","Brachytherapy","Source Location","Medical Physics","Three-Dimensional Line Equation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284785248"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In High Dose Rate brachytherapy, a catheter is placed inside the body and a radioactive source is allowed to dwell at specific positions to treat a tumor. In normal usage, anatomical images acquired before the treatment are used to plan dwell positions, and then the plan is executed without further verifying source locations during treatment. However, slight errors in catheter positioning and shifts in internal anatomy cause variations in source position. In this study, a general method for determining dwell positions during treatment is evaluated. For this method, the treatment source exposes the tumor to radiation and creates an image on a film after the radiation passes through a constructed phantom. 3D line reconstruction is then used to back-extrapolate to the source location. Experiments are performed for several types of catheter movement. Two methods of identifying image locations and two mathematical methods for back-extrapolation are evaluated."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.143","4.07 MB"]},{"key":"dc:title","label":"Title","values":["The Derivation and Testing of Three-Dimensional Line Equations That Predict the Location of Brachytherapy Sources"]}]}],"canonical_facts":{"dc:contributor":["Foy, Brent"],"dc:creator":["Lindsey, Rhett Ellis"],"dc:date":["2010-10-28"],"dc:description":["In High Dose Rate brachytherapy, a catheter is placed inside the body and a radioactive source is allowed to dwell at specific positions to treat a tumor. In normal usage, anatomical images acquired before the treatment are used to plan dwell positions, and then the plan is executed without further verifying source locations during treatment. However, slight errors in catheter positioning and shifts in internal anatomy cause variations in source position. In this study, a general method for determining dwell positions during treatment is evaluated. For this method, the treatment source exposes the tumor to radiation and creates an image on a film after the radiation passes through a constructed phantom. 3D line reconstruction is then used to back-extrapolate to the source location. Experiments are performed for several types of catheter movement. Two methods of identifying image locations and two mathematical methods for back-extrapolation are evaluated."],"dc:format":["application/pdf","p.143","4.07 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284785248"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Health","Health Care","Oncology","Physics","Public Health","Radiation","Radiology","Brachytherapy","Source Location","Medical Physics","Three-Dimensional Line Equation"],"dc:title":["The Derivation and Testing of Three-Dimensional Line Equations That Predict the Location of Brachytherapy Sources"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:10Z"}