{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1284927583"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1284927583","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Dosimetric Effects Near Implanted Vascular Access Ports Under External Electron Beam Radiation","abstract":"<p>Previous studies on dosimetry show important effects for metal vascular access ports for x-rays and electron beams and moderate to no effects for plastic ports for x-ray beams when ports are in the path of the beam. No previous studies exist regarding the effects of electron beams on vascular access ports other than for those made of metal although it has been suggested that electron beam attenuation through non-metal ports may be possible. </p><p>Measurements of relative ionization through the device and adjacent to the device anteriorly and laterally were taken. A clinical particle accelerator delivered typical clinical electron beams of 6, 9, 12, 16, and 20 MeV through the devices. Results showed a noticeable increase in attenuation in the presence of ports, especially for lower energy beams and little or no variation in scattering measurements.</p>","abstract_html":"&lt;p&gt;Previous studies on dosimetry show important effects for metal vascular access ports for x-rays and electron beams and moderate to no effects for plastic ports for x-ray beams when ports are in the path of the beam. No previous studies exist regarding the effects of electron beams on vascular access ports other than for those made of metal although it has been suggested that electron beam attenuation through non-metal ports may be possible. &lt;/p&gt;&lt;p&gt;Measurements of relative ionization through the device and adjacent to the device anteriorly and laterally were taken. A clinical particle accelerator delivered typical clinical electron beams of 6, 9, 12, 16, and 20 MeV through the devices. Results showed a noticeable increase in attenuation in the presence of ports, especially for lower energy beams and little or no variation in scattering measurements.&lt;/p&gt;","abstract_has_math":false,"creators":["Coll Segarra, David"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Foy, Brent"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-10-28","date_published":"2010-10-28","updated_at":"2026-11-26T04:32:10Z","subjects":["Biomedical Research","Biophysics","Health","Oncology","Physics","Radiation","Radiology","vascular access port","electron beam","dosimetry","attenuation","lateral scatter","backscatter"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284927583","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1284927583","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1284927583","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1284927583","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Foy, Brent"]},{"key":"dc:creator","label":"Author","values":["Coll Segarra, David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-10-28"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Research","Biophysics","Health","Oncology","Physics","Radiation","Radiology","vascular access port","electron beam","dosimetry","attenuation","lateral scatter","backscatter"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284927583"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Previous studies on dosimetry show important effects for metal vascular access ports for x-rays and electron beams and moderate to no effects for plastic ports for x-ray beams when ports are in the path of the beam. No previous studies exist regarding the effects of electron beams on vascular access ports other than for those made of metal although it has been suggested that electron beam attenuation through non-metal ports may be possible. </p><p>Measurements of relative ionization through the device and adjacent to the device anteriorly and laterally were taken. A clinical particle accelerator delivered typical clinical electron beams of 6, 9, 12, 16, and 20 MeV through the devices. Results showed a noticeable increase in attenuation in the presence of ports, especially for lower energy beams and little or no variation in scattering measurements.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.90","10.44 MB"]},{"key":"dc:title","label":"Title","values":["Dosimetric Effects Near Implanted Vascular Access Ports Under External Electron Beam Radiation"]}]}],"canonical_facts":{"dc:contributor":["Foy, Brent"],"dc:creator":["Coll Segarra, David"],"dc:date":["2010-10-28"],"dc:description":["<p>Previous studies on dosimetry show important effects for metal vascular access ports for x-rays and electron beams and moderate to no effects for plastic ports for x-ray beams when ports are in the path of the beam. No previous studies exist regarding the effects of electron beams on vascular access ports other than for those made of metal although it has been suggested that electron beam attenuation through non-metal ports may be possible. </p><p>Measurements of relative ionization through the device and adjacent to the device anteriorly and laterally were taken. A clinical particle accelerator delivered typical clinical electron beams of 6, 9, 12, 16, and 20 MeV through the devices. Results showed a noticeable increase in attenuation in the presence of ports, especially for lower energy beams and little or no variation in scattering measurements.</p>"],"dc:format":["application/pdf","p.90","10.44 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1284927583"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Research","Biophysics","Health","Oncology","Physics","Radiation","Radiology","vascular access port","electron beam","dosimetry","attenuation","lateral scatter","backscatter"],"dc:title":["Dosimetric Effects Near Implanted Vascular Access Ports Under External Electron Beam Radiation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:10Z"}