{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1308095868"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1308095868","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Computed Tomography Reconstruction: Investigating the Effect of Varying Circle Diameter","abstract":"<p>In Computed Tomography (CT) reconstruction, several methods for determining the intensity of individual pixels from the back-projection of the scanned profiles exist. The standard reconstruction method uses linear interpolation between ray values to determine pixel intensity. This study quantifies the effects of varying circle diameter on the accuracy of an alternative method where the pixel is approximated as a circle and the area contributions calculated. </p><p>A library of 104 scans in 3 image families was created by a synthetic CT scanner and reconstructed with circle radii from 0.1 to 1.0 pixel in 0.1 pixel steps. Images were compared against a baseline and accuracy measured. Image quality was poor and measures erratic for radii smaller than 0.5 pixels where it stabilized. The overall optimum of the radius was determined to be 0.5 pixels for all images. The reconstructed image quality was not a significant improvement over the standard linear interpolation method.</p>","abstract_html":"&lt;p&gt;In Computed Tomography (CT) reconstruction, several methods for determining the intensity of individual pixels from the back-projection of the scanned profiles exist. The standard reconstruction method uses linear interpolation between ray values to determine pixel intensity. This study quantifies the effects of varying circle diameter on the accuracy of an alternative method where the pixel is approximated as a circle and the area contributions calculated. &lt;/p&gt;&lt;p&gt;A library of 104 scans in 3 image families was created by a synthetic CT scanner and reconstructed with circle radii from 0.1 to 1.0 pixel in 0.1 pixel steps. Images were compared against a baseline and accuracy measured. Image quality was poor and measures erratic for radii smaller than 0.5 pixels where it stabilized. The overall optimum of the radius was determined to be 0.5 pixels for all images. The reconstructed image quality was not a significant improvement over the standard linear interpolation method.&lt;/p&gt;","abstract_has_math":false,"creators":["Sanders, William F., IV"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":["Foy, Brent"],"committee_members":[],"year":2011,"date_issued":"2011-06-21","date_published":"2011-06-21","updated_at":"2026-11-27T04:38:30Z","subjects":["Biomedical Engineering","Medical Imaging","Physics","Computed Tomography","Filtered Backprojection","Fourier","Circle","Area"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1308095868","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1308095868","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1308095868","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1308095868","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Foy, Brent"]},{"key":"dc:creator","label":"Author","values":["Sanders, William F., IV"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-06-21"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Medical Imaging","Physics","Computed Tomography","Filtered Backprojection","Fourier","Circle","Area"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1308095868"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>In Computed Tomography (CT) reconstruction, several methods for determining the intensity of individual pixels from the back-projection of the scanned profiles exist. The standard reconstruction method uses linear interpolation between ray values to determine pixel intensity. This study quantifies the effects of varying circle diameter on the accuracy of an alternative method where the pixel is approximated as a circle and the area contributions calculated. </p><p>A library of 104 scans in 3 image families was created by a synthetic CT scanner and reconstructed with circle radii from 0.1 to 1.0 pixel in 0.1 pixel steps. Images were compared against a baseline and accuracy measured. Image quality was poor and measures erratic for radii smaller than 0.5 pixels where it stabilized. The overall optimum of the radius was determined to be 0.5 pixels for all images. The reconstructed image quality was not a significant improvement over the standard linear interpolation method.</p>"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.72","1.21 MB"]},{"key":"dc:title","label":"Title","values":["Computed Tomography Reconstruction: Investigating the Effect of Varying Circle Diameter"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Foy, Brent"],"dc:creator":["Sanders, William F., IV"],"dc:date":["2011-06-21"],"dc:description":["<p>In Computed Tomography (CT) reconstruction, several methods for determining the intensity of individual pixels from the back-projection of the scanned profiles exist. The standard reconstruction method uses linear interpolation between ray values to determine pixel intensity. This study quantifies the effects of varying circle diameter on the accuracy of an alternative method where the pixel is approximated as a circle and the area contributions calculated. </p><p>A library of 104 scans in 3 image families was created by a synthetic CT scanner and reconstructed with circle radii from 0.1 to 1.0 pixel in 0.1 pixel steps. Images were compared against a baseline and accuracy measured. Image quality was poor and measures erratic for radii smaller than 0.5 pixels where it stabilized. The overall optimum of the radius was determined to be 0.5 pixels for all images. The reconstructed image quality was not a significant improvement over the standard linear interpolation method.</p>"],"dc:format":["application/pdf","p.72","1.21 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1308095868"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Medical Imaging","Physics","Computed Tomography","Filtered Backprojection","Fourier","Circle","Area"],"dc:title":["Computed Tomography Reconstruction: Investigating the Effect of Varying Circle Diameter"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:38:30Z"}