{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1309616451"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1309616451","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Predicting Vigilance Performance Under Transcranial Direct Current Stimulation","abstract":"A brain stimulation technology called transcranial direct current stimulation (tDCS) may potentially mitigate the vigilance decrement. To practically use such technology, however, a model is necessary that indicates vigilance performance, both when stimulation is being applied and not applied. To address this issue, the author developed models capable of predicting vigilance performance in real and control stimulation conditions using previous tDCS-study data. The “all possible combinations” regression method produced over 200 models, later screened to 10. The model with the best average %error (11.49 ± 0.10) used left hemispheric cerebral blood flow velocity (CBFVL) as its sole input term-accounting for 95.7% of the performance variability (linear best-fit slope of 0.8585). When applied to the control stimulation condition, the model had an average %error of 16.76 ± 0.17 and linear best-fit slope of 0.9278. Such results suggest that CBFVL may be useful as a vigilance performance metric during tDCS applications.","abstract_html":"A brain stimulation technology called transcranial direct current stimulation (tDCS) may potentially mitigate the vigilance decrement. To practically use such technology, however, a model is necessary that indicates vigilance performance, both when stimulation is being applied and not applied. To address this issue, the author developed models capable of predicting vigilance performance in real and control stimulation conditions using previous tDCS-study data. The “all possible combinations” regression method produced over 200 models, later screened to 10. The model with the best average %error (11.49 ± 0.10) used left hemispheric cerebral blood flow velocity (CBFVL) as its sole input term-accounting for 95.7% of the performance variability (linear best-fit slope of 0.8585). When applied to the control stimulation condition, the model had an average %error of 16.76 ± 0.17 and linear best-fit slope of 0.9278. Such results suggest that CBFVL may be useful as a vigilance performance metric during tDCS applications.","abstract_has_math":false,"creators":["Bridges, Nathaniel Reese"],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Gallimore, Jennie"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-07-05","date_published":"2011-07-05","updated_at":"2026-11-26T04:32:24Z","subjects":["Biomedical Engineering","Psychology","transcranial direct current stimulation","transcranial doppler","vigilance","sustained attention","cerebral blood flow","cognitive enhancement"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1309616451","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1309616451","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1309616451","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1309616451","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gallimore, Jennie"]},{"key":"dc:creator","label":"Author","values":["Bridges, Nathaniel Reese"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-07-05"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Psychology","transcranial direct current stimulation","transcranial doppler","vigilance","sustained attention","cerebral blood flow","cognitive enhancement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1309616451"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A brain stimulation technology called transcranial direct current stimulation (tDCS) may potentially mitigate the vigilance decrement. To practically use such technology, however, a model is necessary that indicates vigilance performance, both when stimulation is being applied and not applied. To address this issue, the author developed models capable of predicting vigilance performance in real and control stimulation conditions using previous tDCS-study data. The “all possible combinations” regression method produced over 200 models, later screened to 10. The model with the best average %error (11.49 ± 0.10) used left hemispheric cerebral blood flow velocity (CBFVL) as its sole input term-accounting for 95.7% of the performance variability (linear best-fit slope of 0.8585). When applied to the control stimulation condition, the model had an average %error of 16.76 ± 0.17 and linear best-fit slope of 0.9278. Such results suggest that CBFVL may be useful as a vigilance performance metric during tDCS applications."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.146","1.61 MB"]},{"key":"dc:title","label":"Title","values":["Predicting Vigilance Performance Under Transcranial Direct Current Stimulation"]}]}],"canonical_facts":{"dc:contributor":["Gallimore, Jennie"],"dc:creator":["Bridges, Nathaniel Reese"],"dc:date":["2011-07-05"],"dc:description":["A brain stimulation technology called transcranial direct current stimulation (tDCS) may potentially mitigate the vigilance decrement. To practically use such technology, however, a model is necessary that indicates vigilance performance, both when stimulation is being applied and not applied. To address this issue, the author developed models capable of predicting vigilance performance in real and control stimulation conditions using previous tDCS-study data. The “all possible combinations” regression method produced over 200 models, later screened to 10. The model with the best average %error (11.49 ± 0.10) used left hemispheric cerebral blood flow velocity (CBFVL) as its sole input term-accounting for 95.7% of the performance variability (linear best-fit slope of 0.8585). When applied to the control stimulation condition, the model had an average %error of 16.76 ± 0.17 and linear best-fit slope of 0.9278. Such results suggest that CBFVL may be useful as a vigilance performance metric during tDCS applications."],"dc:format":["application/pdf","p.146","1.61 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1309616451"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Psychology","transcranial direct current stimulation","transcranial doppler","vigilance","sustained attention","cerebral blood flow","cognitive enhancement"],"dc:title":["Predicting Vigilance Performance Under Transcranial Direct Current Stimulation"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:24Z"}