{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1310134767"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1310134767","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Influence of Design Parameters on Cup-Stem Orientations for Impingement free Range of Motion in Hip Implants","abstract":"The objective of this investigation is to determine the optimum positions of the prosthesis in total hip arthroplasty that produce least amount of impingement. Theoretical ranges of six basic hip motions were determined under walking, stumbling, internal rotation at 90 flexion and external rotation at 0 extension with 15 abduction, using mathematical models and validated for impingement using finite element analysis. A generalized approach, where impingement does not occur, was developed in this study to understand influence of design parameters such as head-neck ratio, neck-shaft angle, oscillation angle, and stem offset on cup-stem orientations such as cup inclination, cup anteversion, and stem antetorsion. Stems with head-neck ratio lower than 2.3 and neck shaft angle greater than 135 did not impinge. For impingement free range of motion, cups should be anteverted more when stems with high neck shaft angle are combined with low stem offset and antetorsion.","abstract_html":"The objective of this investigation is to determine the optimum positions of the prosthesis in total hip arthroplasty that produce least amount of impingement. Theoretical ranges of six basic hip motions were determined under walking, stumbling, internal rotation at 90 flexion and external rotation at 0 extension with 15 abduction, using mathematical models and validated for impingement using finite element analysis. A generalized approach, where impingement does not occur, was developed in this study to understand influence of design parameters such as head-neck ratio, neck-shaft angle, oscillation angle, and stem offset on cup-stem orientations such as cup inclination, cup anteversion, and stem antetorsion. Stems with head-neck ratio lower than 2.3 and neck shaft angle greater than 135 did not impinge. For impingement free range of motion, cups should be anteverted more when stems with high neck shaft angle are combined with low stem offset and antetorsion.","abstract_has_math":false,"creators":["Patel, Dishita Prakashbhai"],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Goswami, Tarun"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-07-15","date_published":"2011-07-15","updated_at":"2026-11-26T04:32:24Z","subjects":["Biomedical Engineering","Biomedical Research","Surgery","hip implants","impingement","range of motion","cup-stem orientations","finite element analysis of hip implants"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1310134767","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1310134767","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1310134767","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1310134767","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Goswami, Tarun"]},{"key":"dc:creator","label":"Author","values":["Patel, Dishita Prakashbhai"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-07-15"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Surgery","hip implants","impingement","range of motion","cup-stem orientations","finite element analysis of hip implants"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1310134767"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The objective of this investigation is to determine the optimum positions of the prosthesis in total hip arthroplasty that produce least amount of impingement. Theoretical ranges of six basic hip motions were determined under walking, stumbling, internal rotation at 90 flexion and external rotation at 0 extension with 15 abduction, using mathematical models and validated for impingement using finite element analysis. A generalized approach, where impingement does not occur, was developed in this study to understand influence of design parameters such as head-neck ratio, neck-shaft angle, oscillation angle, and stem offset on cup-stem orientations such as cup inclination, cup anteversion, and stem antetorsion. Stems with head-neck ratio lower than 2.3 and neck shaft angle greater than 135 did not impinge. For impingement free range of motion, cups should be anteverted more when stems with high neck shaft angle are combined with low stem offset and antetorsion."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.115","3.07 MB"]},{"key":"dc:title","label":"Title","values":["Influence of Design Parameters on Cup-Stem Orientations for Impingement free Range of Motion in Hip Implants"]}]}],"canonical_facts":{"dc:contributor":["Goswami, Tarun"],"dc:creator":["Patel, Dishita Prakashbhai"],"dc:date":["2011-07-15"],"dc:description":["The objective of this investigation is to determine the optimum positions of the prosthesis in total hip arthroplasty that produce least amount of impingement. Theoretical ranges of six basic hip motions were determined under walking, stumbling, internal rotation at 90 flexion and external rotation at 0 extension with 15 abduction, using mathematical models and validated for impingement using finite element analysis. A generalized approach, where impingement does not occur, was developed in this study to understand influence of design parameters such as head-neck ratio, neck-shaft angle, oscillation angle, and stem offset on cup-stem orientations such as cup inclination, cup anteversion, and stem antetorsion. Stems with head-neck ratio lower than 2.3 and neck shaft angle greater than 135 did not impinge. For impingement free range of motion, cups should be anteverted more when stems with high neck shaft angle are combined with low stem offset and antetorsion."],"dc:format":["application/pdf","p.115","3.07 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1310134767"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Surgery","hip implants","impingement","range of motion","cup-stem orientations","finite element analysis of hip implants"],"dc:title":["Influence of Design Parameters on Cup-Stem Orientations for Impingement free Range of Motion in Hip Implants"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:24Z"}