{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1316534684"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1316534684","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Cervical Spine Biomechanical Behavior and Injury","abstract":"A finite element model of the cervical spine including the C2 through C7 levels was developed in order to study the behavior of the cervical spine region. The model was validated in flexion extension, bending, and rotational load scenarios. The model was found to represent the biomechanical behavior of the cervical spine. The validated cervical spine finite element model was used to study spinal injury and disease processes. The model provided qualitative estimates of load carrying and stress distribution as well as range of motion.","abstract_html":"A finite element model of the cervical spine including the C2 through C7 levels was developed in order to study the behavior of the cervical spine region. The model was validated in flexion extension, bending, and rotational load scenarios. The model was found to represent the biomechanical behavior of the cervical spine. The validated cervical spine finite element model was used to study spinal injury and disease processes. The model provided qualitative estimates of load carrying and stress distribution as well as range of motion.","abstract_has_math":false,"creators":["Makola, Mbulelo T."],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Goswami, Tarun"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-09-23","date_published":"2011-09-23","updated_at":"2026-11-26T04:32:24Z","subjects":["Biomechanics","Biomedical Engineering","Biomedical Research","Cervical Spine","Finite Element Analysis","Injury"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1316534684","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1316534684","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1316534684","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1316534684","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Goswami, Tarun"]},{"key":"dc:creator","label":"Author","values":["Makola, Mbulelo T."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-09-23"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomechanics","Biomedical Engineering","Biomedical Research","Cervical Spine","Finite Element Analysis","Injury"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1316534684"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A finite element model of the cervical spine including the C2 through C7 levels was developed in order to study the behavior of the cervical spine region. The model was validated in flexion extension, bending, and rotational load scenarios. The model was found to represent the biomechanical behavior of the cervical spine. The validated cervical spine finite element model was used to study spinal injury and disease processes. The model provided qualitative estimates of load carrying and stress distribution as well as range of motion."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.84","1.72 MB"]},{"key":"dc:title","label":"Title","values":["Cervical Spine Biomechanical Behavior and Injury"]}]}],"canonical_facts":{"dc:contributor":["Goswami, Tarun"],"dc:creator":["Makola, Mbulelo T."],"dc:date":["2011-09-23"],"dc:description":["A finite element model of the cervical spine including the C2 through C7 levels was developed in order to study the behavior of the cervical spine region. The model was validated in flexion extension, bending, and rotational load scenarios. The model was found to represent the biomechanical behavior of the cervical spine. The validated cervical spine finite element model was used to study spinal injury and disease processes. The model provided qualitative estimates of load carrying and stress distribution as well as range of motion."],"dc:format":["application/pdf","p.84","1.72 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1316534684"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomechanics","Biomedical Engineering","Biomedical Research","Cervical Spine","Finite Element Analysis","Injury"],"dc:title":["Cervical Spine Biomechanical Behavior and Injury"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:24Z"}