{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1344523437"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1344523437","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Near Single-Molecule SERS-Based Detection Using Ultrafiltered, Unfunctionalized Silver Nanoparticles","abstract":"Silver nanoparticles (AgNPs) are currently widely-used in consumer products, therapeutics, biomedical devices, and electronics. Yet, one application for which AgNPs have been used extensively is surface-enhanced Raman spectroscopy (SERS)-based sensing. However, AgNP size and aggregation state are known to greatly influence these applications. This works aimed 1) to synthesize a large volume of unfunctionalized, Creighton AgNPs, to characterize their chemical and physical properties, 2) then to size-select AgNPs of 1-50 nm and 50-100 nm in diameter and to concentrate them using a three-step, “green” tangential flow ultrafiltration (TFU) process. 3) Finally, to determine and compare the SERS-based sensing capabilities of the Creighton AgNPs of various sizes (1-50 nm, 50-100 nm, and 1-100 nm). It was hypothesized that the concentrated colloidal AgNPs (1-50 nm and 50-100 nm) will lead to greater SERS enhancement factors compared to that of the original Creighton colloid due the presence of a significantly larger number of SERS “hot spots” within the focal volume. The three aims were successfully accomplished, and the proposed hypothesis was validated. AgNPs of 50-100 nm in diameter were found to have the best SERS-based sensing capabilities in non-resonant conditions due to a greater abundance of optimally sized AgNPs. The surface enhancement factor of these AgNPs was 2.1 x 10<sup>6</sup> at 10<sup>-8</sup> M of rhodamine 6G, which facilitated the detection of ~11 molecules within the focal volume.","abstract_html":"Silver nanoparticles (AgNPs) are currently widely-used in consumer products, therapeutics, biomedical devices, and electronics. Yet, one application for which AgNPs have been used extensively is surface-enhanced Raman spectroscopy (SERS)-based sensing. However, AgNP size and aggregation state are known to greatly influence these applications. This works aimed 1) to synthesize a large volume of unfunctionalized, Creighton AgNPs, to characterize their chemical and physical properties, 2) then to size-select AgNPs of 1-50 nm and 50-100 nm in diameter and to concentrate them using a three-step, “green” tangential flow ultrafiltration (TFU) process. 3) Finally, to determine and compare the SERS-based sensing capabilities of the Creighton AgNPs of various sizes (1-50 nm, 50-100 nm, and 1-100 nm). It was hypothesized that the concentrated colloidal AgNPs (1-50 nm and 50-100 nm) will lead to greater SERS enhancement factors compared to that of the original Creighton colloid due the presence of a significantly larger number of SERS “hot spots” within the focal volume. The three aims were successfully accomplished, and the proposed hypothesis was validated. AgNPs of 50-100 nm in diameter were found to have the best SERS-based sensing capabilities in non-resonant conditions due to a greater abundance of optimally sized AgNPs. The surface enhancement factor of these AgNPs was 2.1 x 10&lt;sup&gt;6&lt;/sup&gt; at 10&lt;sup&gt;-8&lt;/sup&gt; M of rhodamine 6G, which facilitated the detection of ~11 molecules within the focal volume.","abstract_has_math":false,"creators":["Baker, Joshua Dale"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":["Sizemore, Ioana E.P.","Higgins, Steven R."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-09-05","date_published":"2012-09-05","updated_at":"2026-11-26T04:32:24Z","subjects":["Nanoscience","Nanotechnology","Physical Chemistry","Raman Spectroscopy","SERS","Silver Nanoparticles"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1344523437","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1344523437","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1344523437","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1344523437","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sizemore, Ioana E.P.","Higgins, Steven R."]},{"key":"dc:creator","label":"Author","values":["Baker, Joshua Dale"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-09-05"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nanoscience","Nanotechnology","Physical Chemistry","Raman Spectroscopy","SERS","Silver Nanoparticles"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1344523437"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Silver nanoparticles (AgNPs) are currently widely-used in consumer products, therapeutics, biomedical devices, and electronics. Yet, one application for which AgNPs have been used extensively is surface-enhanced Raman spectroscopy (SERS)-based sensing. However, AgNP size and aggregation state are known to greatly influence these applications. This works aimed 1) to synthesize a large volume of unfunctionalized, Creighton AgNPs, to characterize their chemical and physical properties, 2) then to size-select AgNPs of 1-50 nm and 50-100 nm in diameter and to concentrate them using a three-step, “green” tangential flow ultrafiltration (TFU) process. 3) Finally, to determine and compare the SERS-based sensing capabilities of the Creighton AgNPs of various sizes (1-50 nm, 50-100 nm, and 1-100 nm). It was hypothesized that the concentrated colloidal AgNPs (1-50 nm and 50-100 nm) will lead to greater SERS enhancement factors compared to that of the original Creighton colloid due the presence of a significantly larger number of SERS “hot spots” within the focal volume. The three aims were successfully accomplished, and the proposed hypothesis was validated. AgNPs of 50-100 nm in diameter were found to have the best SERS-based sensing capabilities in non-resonant conditions due to a greater abundance of optimally sized AgNPs. The surface enhancement factor of these AgNPs was 2.1 x 10<sup>6</sup> at 10<sup>-8</sup> M of rhodamine 6G, which facilitated the detection of ~11 molecules within the focal volume."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.75","9.05 MB"]},{"key":"dc:title","label":"Title","values":["Near Single-Molecule SERS-Based Detection Using Ultrafiltered, Unfunctionalized Silver Nanoparticles"]}]}],"canonical_facts":{"dc:contributor":["Sizemore, Ioana E.P.","Higgins, Steven R."],"dc:creator":["Baker, Joshua Dale"],"dc:date":["2012-09-05"],"dc:description":["Silver nanoparticles (AgNPs) are currently widely-used in consumer products, therapeutics, biomedical devices, and electronics. Yet, one application for which AgNPs have been used extensively is surface-enhanced Raman spectroscopy (SERS)-based sensing. However, AgNP size and aggregation state are known to greatly influence these applications. This works aimed 1) to synthesize a large volume of unfunctionalized, Creighton AgNPs, to characterize their chemical and physical properties, 2) then to size-select AgNPs of 1-50 nm and 50-100 nm in diameter and to concentrate them using a three-step, “green” tangential flow ultrafiltration (TFU) process. 3) Finally, to determine and compare the SERS-based sensing capabilities of the Creighton AgNPs of various sizes (1-50 nm, 50-100 nm, and 1-100 nm). It was hypothesized that the concentrated colloidal AgNPs (1-50 nm and 50-100 nm) will lead to greater SERS enhancement factors compared to that of the original Creighton colloid due the presence of a significantly larger number of SERS “hot spots” within the focal volume. The three aims were successfully accomplished, and the proposed hypothesis was validated. AgNPs of 50-100 nm in diameter were found to have the best SERS-based sensing capabilities in non-resonant conditions due to a greater abundance of optimally sized AgNPs. The surface enhancement factor of these AgNPs was 2.1 x 10<sup>6</sup> at 10<sup>-8</sup> M of rhodamine 6G, which facilitated the detection of ~11 molecules within the focal volume."],"dc:format":["application/pdf","p.75","9.05 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1344523437"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Nanoscience","Nanotechnology","Physical Chemistry","Raman Spectroscopy","SERS","Silver Nanoparticles"],"dc:title":["Near Single-Molecule SERS-Based Detection Using Ultrafiltered, Unfunctionalized Silver Nanoparticles"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:32:24Z"}