{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1387979181"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1387979181","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Capturing and Modeling a Three-Dimensional Stationary Noise Source Directivity Pattern with a Dynamic Array in the Near Field","abstract":"The author has studied several legacy landmark methodologies to develop an original measurement technique. Spherical harmonics modeling practices were leveraged to accurately represent a source directivity pattern. In this thesis a lightweight microphone measurement array that was manually maneuvered around a static noise source was employed. The measurement technique consisted of inserting a head-tracker sensor onto the microphone array to allow the location of the captured acoustic Sound Pressure Level (SPL) to be investigated. By leveraging the historical methodologies the acoustic SPL and location data collected with this technique were processes to represent a directivity pattern of the compressor source chosen. The results indicated that the measurement technique is valid for capturing acoustic SPL and location data of a static noise source with a dynamic array. Propagation techniques yielded a ten decibel difference between the measured and predicated SPLs. The dynamic measurement technique and method for characterizing the three-dimensional acoustic directivity of a static noise source is further presented in this thesis.","abstract_html":"The author has studied several legacy landmark methodologies to develop an original measurement technique. Spherical harmonics modeling practices were leveraged to accurately represent a source directivity pattern. In this thesis a lightweight microphone measurement array that was manually maneuvered around a static noise source was employed. The measurement technique consisted of inserting a head-tracker sensor onto the microphone array to allow the location of the captured acoustic Sound Pressure Level (SPL) to be investigated. By leveraging the historical methodologies the acoustic SPL and location data collected with this technique were processes to represent a directivity pattern of the compressor source chosen. The results indicated that the measurement technique is valid for capturing acoustic SPL and location data of a static noise source with a dynamic array. Propagation techniques yielded a ten decibel difference between the measured and predicated SPLs. The dynamic measurement technique and method for characterizing the three-dimensional acoustic directivity of a static noise source is further presented in this thesis.","abstract_has_math":false,"creators":["Mieskoski, Randy"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Mobley, Frank","Petkie, Doug"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-26T04:35:51Z","subjects":["Acoustics","Physics","acoustic modeling and modeling","spherical harmonics","source directivity pattern","microphone array","acoustic Sound Pressure Level -SPL","propagation techniques","static noise source"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1387979181","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1387979181","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1387979181","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1387979181","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mobley, Frank","Petkie, Doug"]},{"key":"dc:creator","label":"Author","values":["Mieskoski, Randy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Acoustics","Physics","acoustic modeling and modeling","spherical harmonics","source directivity pattern","microphone array","acoustic Sound Pressure Level -SPL","propagation techniques","static noise source"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1387979181"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The author has studied several legacy landmark methodologies to develop an original measurement technique. Spherical harmonics modeling practices were leveraged to accurately represent a source directivity pattern. In this thesis a lightweight microphone measurement array that was manually maneuvered around a static noise source was employed. The measurement technique consisted of inserting a head-tracker sensor onto the microphone array to allow the location of the captured acoustic Sound Pressure Level (SPL) to be investigated. By leveraging the historical methodologies the acoustic SPL and location data collected with this technique were processes to represent a directivity pattern of the compressor source chosen. The results indicated that the measurement technique is valid for capturing acoustic SPL and location data of a static noise source with a dynamic array. Propagation techniques yielded a ten decibel difference between the measured and predicated SPLs. The dynamic measurement technique and method for characterizing the three-dimensional acoustic directivity of a static noise source is further presented in this thesis."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.105","3.21 MB"]},{"key":"dc:title","label":"Title","values":["Capturing and Modeling a Three-Dimensional Stationary Noise Source Directivity Pattern with a Dynamic Array in the Near Field"]}]}],"canonical_facts":{"dc:contributor":["Mobley, Frank","Petkie, Doug"],"dc:creator":["Mieskoski, Randy"],"dc:date":["2013"],"dc:description":["The author has studied several legacy landmark methodologies to develop an original measurement technique. Spherical harmonics modeling practices were leveraged to accurately represent a source directivity pattern. In this thesis a lightweight microphone measurement array that was manually maneuvered around a static noise source was employed. The measurement technique consisted of inserting a head-tracker sensor onto the microphone array to allow the location of the captured acoustic Sound Pressure Level (SPL) to be investigated. By leveraging the historical methodologies the acoustic SPL and location data collected with this technique were processes to represent a directivity pattern of the compressor source chosen. The results indicated that the measurement technique is valid for capturing acoustic SPL and location data of a static noise source with a dynamic array. Propagation techniques yielded a ten decibel difference between the measured and predicated SPLs. The dynamic measurement technique and method for characterizing the three-dimensional acoustic directivity of a static noise source is further presented in this thesis."],"dc:format":["application/pdf","p.105","3.21 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1387979181"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Acoustics","Physics","acoustic modeling and modeling","spherical harmonics","source directivity pattern","microphone array","acoustic Sound Pressure Level -SPL","propagation techniques","static noise source"],"dc:title":["Capturing and Modeling a Three-Dimensional Stationary Noise Source Directivity Pattern with a Dynamic Array in the Near Field"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T04:35:51Z"}