{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1408732018"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1408732018","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Chemical Analysis of Exhaled Breath by Means of Terahertz Rotational Spectroscopy","abstract":"Terahertz spectroscopy, due to the high sensitivity and specificity that it affords, has been incorporated in many fields to aid in the chemical analysis of gases. One potential application is to detect bio-markers in human breath for early diagnosis. Our current aim of our research is to establish a relationship between several chemicals and the glucose levels from human exhaled breath. 20 chemical including Acetone, Carbon monoxide (CO), Methanol were studied. Volunteers’ breath samples were processed through a pre-concentration system before being injected into the spectrometer. Initially, a commercial preconcentration system, Entech 7100A, was used. However, due to the limitations of Entech 7100A, a custom built pre-concentration system that incorporates a sorbent pack from Markes International Ltd. has been developed. The new preconcentration system and preliminary results on exhaled breath analysis are presented here.","abstract_html":"Terahertz spectroscopy, due to the high sensitivity and specificity that it affords, has been incorporated in many fields to aid in the chemical analysis of gases. One potential application is to detect bio-markers in human breath for early diagnosis. Our current aim of our research is to establish a relationship between several chemicals and the glucose levels from human exhaled breath. 20 chemical including Acetone, Carbon monoxide (CO), Methanol were studied. Volunteers’ breath samples were processed through a pre-concentration system before being injected into the spectrometer. Initially, a commercial preconcentration system, Entech 7100A, was used. However, due to the limitations of Entech 7100A, a custom built pre-concentration system that incorporates a sorbent pack from Markes International Ltd. has been developed. The new preconcentration system and preliminary results on exhaled breath analysis are presented here.","abstract_has_math":false,"creators":["Guo, Tianle"],"institution":"Wright State University","degree_name":"Master of Science (MS)","degree_level":"masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Medvedev, Ivan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-08-26","date_published":"2014-08-26","updated_at":"2026-11-26T05:20:23Z","subjects":["Physics"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1408732018","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1408732018","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1408732018","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1408732018","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Medvedev, Ivan"]},{"key":"dc:creator","label":"Author","values":["Guo, Tianle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-08-26"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MS)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1408732018"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Terahertz spectroscopy, due to the high sensitivity and specificity that it affords, has been incorporated in many fields to aid in the chemical analysis of gases. One potential application is to detect bio-markers in human breath for early diagnosis. Our current aim of our research is to establish a relationship between several chemicals and the glucose levels from human exhaled breath. 20 chemical including Acetone, Carbon monoxide (CO), Methanol were studied. Volunteers’ breath samples were processed through a pre-concentration system before being injected into the spectrometer. Initially, a commercial preconcentration system, Entech 7100A, was used. However, due to the limitations of Entech 7100A, a custom built pre-concentration system that incorporates a sorbent pack from Markes International Ltd. has been developed. The new preconcentration system and preliminary results on exhaled breath analysis are presented here."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.54","2.82 MB"]},{"key":"dc:title","label":"Title","values":["Chemical Analysis of Exhaled Breath by Means of Terahertz Rotational Spectroscopy"]}]}],"canonical_facts":{"dc:contributor":["Medvedev, Ivan"],"dc:creator":["Guo, Tianle"],"dc:date":["2014-08-26"],"dc:description":["Terahertz spectroscopy, due to the high sensitivity and specificity that it affords, has been incorporated in many fields to aid in the chemical analysis of gases. One potential application is to detect bio-markers in human breath for early diagnosis. Our current aim of our research is to establish a relationship between several chemicals and the glucose levels from human exhaled breath. 20 chemical including Acetone, Carbon monoxide (CO), Methanol were studied. Volunteers’ breath samples were processed through a pre-concentration system before being injected into the spectrometer. Initially, a commercial preconcentration system, Entech 7100A, was used. However, due to the limitations of Entech 7100A, a custom built pre-concentration system that incorporates a sorbent pack from Markes International Ltd. has been developed. The new preconcentration system and preliminary results on exhaled breath analysis are presented here."],"dc:format":["application/pdf","p.54","2.82 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1408732018"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Physics"],"dc:title":["Chemical Analysis of Exhaled Breath by Means of Terahertz Rotational Spectroscopy"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science (MS)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T05:20:23Z"}