{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1430403954"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1430403954","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Measuring Pulse Rate Variability During Motion Artifact with a Non-Contact, Multi-Imager Photoplethysmography System","abstract":"Non-contact imaging photoplethysmography is an exciting new field based on the principles of traditional photoplethysmography where viable signals can now be acquired without the use of contact equipment. Recent advances regarding non-contact imaging photoplethysmography have permitted a wide range of new possibilities focused on sensing the cardiopulmonary system. Physiological metrics such as pulse rate, respiration rate, and pulse rate variability can be obtained by current photoplethysmographic imaging methods. Although previous systems were challenged by head-motion artifacts, the mitigation of rigid head-motion artifacts has been demonstrated with a multi-imager design. This study investigated the feasibility and accuracy of pulse rate variability utilizing a multi-imager recording system. Parameters such as sampling rate, image resolution, and number of imagers utilized were examined in an attempt to minimize overall system data bandwidth. Accurate pulse rate variability metrics where found within the frequency and temporal domains, along with promising results regarding the aforementioned input parameters.","abstract_html":"Non-contact imaging photoplethysmography is an exciting new field based on the principles of traditional photoplethysmography where viable signals can now be acquired without the use of contact equipment. Recent advances regarding non-contact imaging photoplethysmography have permitted a wide range of new possibilities focused on sensing the cardiopulmonary system. Physiological metrics such as pulse rate, respiration rate, and pulse rate variability can be obtained by current photoplethysmographic imaging methods. Although previous systems were challenged by head-motion artifacts, the mitigation of rigid head-motion artifacts has been demonstrated with a multi-imager design. This study investigated the feasibility and accuracy of pulse rate variability utilizing a multi-imager recording system. Parameters such as sampling rate, image resolution, and number of imagers utilized were examined in an attempt to minimize overall system data bandwidth. Accurate pulse rate variability metrics where found within the frequency and temporal domains, along with promising results regarding the aforementioned input parameters.","abstract_has_math":false,"creators":["Kiehl, Zachary Adam"],"institution":"Wright State University","degree_name":"Master of Science in Biomedical Engineering (MSBME)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Fendley, Mary"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-05-11","date_published":"2015-05-11","updated_at":"2026-11-27T04:40:22Z","subjects":["Biomedical Engineering","Biomedical Research","Imaging Photoplethysmography","Heart Rate Variability","Pulse Rate Variability","Non-Contact Photoplethysmography","Non-Contact Monitoring","Motion Artifact"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1430403954","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1430403954","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1430403954","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1430403954","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Fendley, Mary"]},{"key":"dc:creator","label":"Author","values":["Kiehl, Zachary Adam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-05-11"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MSBME)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Imaging Photoplethysmography","Heart Rate Variability","Pulse Rate Variability","Non-Contact Photoplethysmography","Non-Contact Monitoring","Motion Artifact"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1430403954"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Non-contact imaging photoplethysmography is an exciting new field based on the principles of traditional photoplethysmography where viable signals can now be acquired without the use of contact equipment. Recent advances regarding non-contact imaging photoplethysmography have permitted a wide range of new possibilities focused on sensing the cardiopulmonary system. Physiological metrics such as pulse rate, respiration rate, and pulse rate variability can be obtained by current photoplethysmographic imaging methods. Although previous systems were challenged by head-motion artifacts, the mitigation of rigid head-motion artifacts has been demonstrated with a multi-imager design. This study investigated the feasibility and accuracy of pulse rate variability utilizing a multi-imager recording system. Parameters such as sampling rate, image resolution, and number of imagers utilized were examined in an attempt to minimize overall system data bandwidth. Accurate pulse rate variability metrics where found within the frequency and temporal domains, along with promising results regarding the aforementioned input parameters."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.132","5.31 MB"]},{"key":"dc:title","label":"Title","values":["Measuring Pulse Rate Variability During Motion Artifact with a Non-Contact, Multi-Imager Photoplethysmography System"]}]}],"canonical_facts":{"dc:contributor.advisor":["Fendley, Mary"],"dc:creator":["Kiehl, Zachary Adam"],"dc:date":["2015-05-11"],"dc:description":["Non-contact imaging photoplethysmography is an exciting new field based on the principles of traditional photoplethysmography where viable signals can now be acquired without the use of contact equipment. Recent advances regarding non-contact imaging photoplethysmography have permitted a wide range of new possibilities focused on sensing the cardiopulmonary system. Physiological metrics such as pulse rate, respiration rate, and pulse rate variability can be obtained by current photoplethysmographic imaging methods. Although previous systems were challenged by head-motion artifacts, the mitigation of rigid head-motion artifacts has been demonstrated with a multi-imager design. This study investigated the feasibility and accuracy of pulse rate variability utilizing a multi-imager recording system. Parameters such as sampling rate, image resolution, and number of imagers utilized were examined in an attempt to minimize overall system data bandwidth. Accurate pulse rate variability metrics where found within the frequency and temporal domains, along with promising results regarding the aforementioned input parameters."],"dc:format":["application/pdf","p.132","5.31 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1430403954"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Imaging Photoplethysmography","Heart Rate Variability","Pulse Rate Variability","Non-Contact Photoplethysmography","Non-Contact Monitoring","Motion Artifact"],"dc:title":["Measuring Pulse Rate Variability During Motion Artifact with a Non-Contact, Multi-Imager Photoplethysmography System"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MSBME)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:40:22Z"}