{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1433244703"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1433244703","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"An improved adaptive filtering approach for removing artifact from the electroencephalogram","abstract":"The biophysics of volume conduction that enable electrophysiological data acquisition also result in the mixing of data sources including possible, undesirable noise sources at the electrode interface. This work specifically focuses on improving the performance of the recursive least-squares (RLS) adaptive filtering method for removing eye movement artifact from the electroencephalogram. In biophysically-inspired simulated data, the RLS algorithm is verified to produce results that are inferior to extended infomax independent component analysis (ICA), the most widely used artifact correction approach in this problem space, due to its non-linear filter phase response and the presence of bidirectional contamination, or cross-talk, resultant of volume conduction in electroencephalographic data. The non-linear phase response of the RLS algorithm is mitigated by restricting its filter coefficients to form a linear phase, Type I finite impulse response filter. A reduced effect of cross-talk in RLS is achieved by filtering the reference noise input signal using a combination of non-local means weighting and Bayesian adaptive regression splines smoothing. When compared to extended infomax ICA, the modified RLS adaptive filtering approach meets or exceeds data source recovery accuracy while retaining highly desirable properties not afforded by blind source separation. These results support the use of a modified adaptive filtering approach for the near-ideal removal of eye artifact data from the electroencephalogram.","abstract_html":"The biophysics of volume conduction that enable electrophysiological data acquisition also result in the mixing of data sources including possible, undesirable noise sources at the electrode interface. This work specifically focuses on improving the performance of the recursive least-squares (RLS) adaptive filtering method for removing eye movement artifact from the electroencephalogram. In biophysically-inspired simulated data, the RLS algorithm is verified to produce results that are inferior to extended infomax independent component analysis (ICA), the most widely used artifact correction approach in this problem space, due to its non-linear filter phase response and the presence of bidirectional contamination, or cross-talk, resultant of volume conduction in electroencephalographic data. The non-linear phase response of the RLS algorithm is mitigated by restricting its filter coefficients to form a linear phase, Type I finite impulse response filter. A reduced effect of cross-talk in RLS is achieved by filtering the reference noise input signal using a combination of non-local means weighting and Bayesian adaptive regression splines smoothing. When compared to extended infomax ICA, the modified RLS adaptive filtering approach meets or exceeds data source recovery accuracy while retaining highly desirable properties not afforded by blind source separation. These results support the use of a modified adaptive filtering approach for the near-ideal removal of eye artifact data from the electroencephalogram.","abstract_has_math":false,"creators":["Estepp, Justin Ronald"],"institution":"Wright State University","degree_name":"Master of Science in Biomedical Engineering (MSBME)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["He, Ping"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-06-02","date_published":"2015-06-02","updated_at":"2026-11-26T05:24:35Z","subjects":["Biomedical Engineering","Biomedical Research","Biophysics","Engineering","Neurosciences","eeg","artifact","noise","blind source separation","adaptive filtering","independent component analysis","neurophysiology","electrophysiology","electrooculography","bidirectional contamination","artifact removal"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1433244703","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1433244703","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1433244703","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1433244703","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["He, Ping"]},{"key":"dc:creator","label":"Author","values":["Estepp, Justin Ronald"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-06-02"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MSBME)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Biomedical Research","Biophysics","Engineering","Neurosciences","eeg","artifact","noise","blind source separation","adaptive filtering","independent component analysis","neurophysiology","electrophysiology","electrooculography","bidirectional contamination","artifact removal"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1433244703"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The biophysics of volume conduction that enable electrophysiological data acquisition also result in the mixing of data sources including possible, undesirable noise sources at the electrode interface. This work specifically focuses on improving the performance of the recursive least-squares (RLS) adaptive filtering method for removing eye movement artifact from the electroencephalogram. In biophysically-inspired simulated data, the RLS algorithm is verified to produce results that are inferior to extended infomax independent component analysis (ICA), the most widely used artifact correction approach in this problem space, due to its non-linear filter phase response and the presence of bidirectional contamination, or cross-talk, resultant of volume conduction in electroencephalographic data. The non-linear phase response of the RLS algorithm is mitigated by restricting its filter coefficients to form a linear phase, Type I finite impulse response filter. A reduced effect of cross-talk in RLS is achieved by filtering the reference noise input signal using a combination of non-local means weighting and Bayesian adaptive regression splines smoothing. When compared to extended infomax ICA, the modified RLS adaptive filtering approach meets or exceeds data source recovery accuracy while retaining highly desirable properties not afforded by blind source separation. These results support the use of a modified adaptive filtering approach for the near-ideal removal of eye artifact data from the electroencephalogram."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.130","3.75 MB"]},{"key":"dc:title","label":"Title","values":["An improved adaptive filtering approach for removing artifact from the electroencephalogram"]}]}],"canonical_facts":{"dc:contributor":["He, Ping"],"dc:creator":["Estepp, Justin Ronald"],"dc:date":["2015-06-02"],"dc:description":["The biophysics of volume conduction that enable electrophysiological data acquisition also result in the mixing of data sources including possible, undesirable noise sources at the electrode interface. This work specifically focuses on improving the performance of the recursive least-squares (RLS) adaptive filtering method for removing eye movement artifact from the electroencephalogram. In biophysically-inspired simulated data, the RLS algorithm is verified to produce results that are inferior to extended infomax independent component analysis (ICA), the most widely used artifact correction approach in this problem space, due to its non-linear filter phase response and the presence of bidirectional contamination, or cross-talk, resultant of volume conduction in electroencephalographic data. The non-linear phase response of the RLS algorithm is mitigated by restricting its filter coefficients to form a linear phase, Type I finite impulse response filter. A reduced effect of cross-talk in RLS is achieved by filtering the reference noise input signal using a combination of non-local means weighting and Bayesian adaptive regression splines smoothing. When compared to extended infomax ICA, the modified RLS adaptive filtering approach meets or exceeds data source recovery accuracy while retaining highly desirable properties not afforded by blind source separation. These results support the use of a modified adaptive filtering approach for the near-ideal removal of eye artifact data from the electroencephalogram."],"dc:format":["application/pdf","p.130","3.75 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1433244703"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Biomedical Engineering","Biomedical Research","Biophysics","Engineering","Neurosciences","eeg","artifact","noise","blind source separation","adaptive filtering","independent component analysis","neurophysiology","electrophysiology","electrooculography","bidirectional contamination","artifact removal"],"dc:title":["An improved adaptive filtering approach for removing artifact from the electroencephalogram"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MSBME)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T05:24:35Z"}