{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1441064582"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1441064582","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Verification and Validation of a Transient Heat Exchanger Model","abstract":"A statistical based verification and validation process is applied to the transient modeling of a shell and tube heat exchanger. A generic model of a heat exchanger was developed based on first principles as a sub-system of a larger thermal system model. This model was originally created without any experimental data, as it was not readily available. To provide the data necessary to apply the validation process, a thermal emulator was designed and built that allowed control of all system inputs to the heat exchanger, while also providing the instrumentation to record all required data. A wide test matrix was chosen to fully encompass the expected operational envelope of the heat exchanger. Focus on the collection of experimental data was the minimization of uncertainty, as these uncertainties were amplified once they were propagated through the validation process.The validation process encompasses the completion of sensitivity and uncertainty analyses, uncertainty propagation, verification, and validation. Once these steps were completed using a set of non-ideal experimental data, uncertainty in the transient heat exchanger model is quantified. This manuscript proposes a way to complete the validation process without replicate data sets by utilizing known information about the physical process. At the completion of the process, both uncertainties and model form error are quantified for the system outputs and a statistical validation metric is applied. These outputs help to define whether or not the model captures the physical process to a satisfactory degree while also highlighting avenues for improvement if the uncertainty is deemed too large for the intended application.","abstract_html":"A statistical based verification and validation process is applied to the transient modeling of a shell and tube heat exchanger. A generic model of a heat exchanger was developed based on first principles as a sub-system of a larger thermal system model. This model was originally created without any experimental data, as it was not readily available. To provide the data necessary to apply the validation process, a thermal emulator was designed and built that allowed control of all system inputs to the heat exchanger, while also providing the instrumentation to record all required data. A wide test matrix was chosen to fully encompass the expected operational envelope of the heat exchanger. Focus on the collection of experimental data was the minimization of uncertainty, as these uncertainties were amplified once they were propagated through the validation process.The validation process encompasses the completion of sensitivity and uncertainty analyses, uncertainty propagation, verification, and validation. Once these steps were completed using a set of non-ideal experimental data, uncertainty in the transient heat exchanger model is quantified. This manuscript proposes a way to complete the validation process without replicate data sets by utilizing known information about the physical process. At the completion of the process, both uncertainties and model form error are quantified for the system outputs and a statistical validation metric is applied. These outputs help to define whether or not the model captures the physical process to a satisfactory degree while also highlighting avenues for improvement if the uncertainty is deemed too large for the intended application.","abstract_has_math":false,"creators":["Carper, Jayme Lee"],"institution":"Wright State University","degree_name":"Master of Science in Engineering (MSEgr)","degree_level":"masters","degree_discipline":"Renewable and Clean Energy","degree_department":null,"school":null,"contributors":[],"advisors":["Roberts, Rory"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09-01","date_published":"2015-09-01","updated_at":"2026-11-27T04:40:38Z","subjects":["Engineering","Mechanical Engineering","verification","validation","transient heat exchanger model","first principles","thermal model","uncertainty","uncertainty propagation","sensitivity analysis"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1441064582","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1441064582","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1441064582","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1441064582","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Roberts, Rory"]},{"key":"dc:creator","label":"Author","values":["Carper, Jayme Lee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-09-01"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Renewable and Clean Energy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering (MSEgr)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Mechanical Engineering","verification","validation","transient heat exchanger model","first principles","thermal model","uncertainty","uncertainty propagation","sensitivity analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1441064582"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A statistical based verification and validation process is applied to the transient modeling of a shell and tube heat exchanger. A generic model of a heat exchanger was developed based on first principles as a sub-system of a larger thermal system model. This model was originally created without any experimental data, as it was not readily available. To provide the data necessary to apply the validation process, a thermal emulator was designed and built that allowed control of all system inputs to the heat exchanger, while also providing the instrumentation to record all required data. A wide test matrix was chosen to fully encompass the expected operational envelope of the heat exchanger. Focus on the collection of experimental data was the minimization of uncertainty, as these uncertainties were amplified once they were propagated through the validation process.The validation process encompasses the completion of sensitivity and uncertainty analyses, uncertainty propagation, verification, and validation. Once these steps were completed using a set of non-ideal experimental data, uncertainty in the transient heat exchanger model is quantified. This manuscript proposes a way to complete the validation process without replicate data sets by utilizing known information about the physical process. At the completion of the process, both uncertainties and model form error are quantified for the system outputs and a statistical validation metric is applied. These outputs help to define whether or not the model captures the physical process to a satisfactory degree while also highlighting avenues for improvement if the uncertainty is deemed too large for the intended application."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.232","9.26 MB"]},{"key":"dc:title","label":"Title","values":["Verification and Validation of a Transient Heat Exchanger Model"]}]}],"canonical_facts":{"dc:contributor.advisor":["Roberts, Rory"],"dc:creator":["Carper, Jayme Lee"],"dc:date":["2015-09-01"],"dc:description":["A statistical based verification and validation process is applied to the transient modeling of a shell and tube heat exchanger. A generic model of a heat exchanger was developed based on first principles as a sub-system of a larger thermal system model. This model was originally created without any experimental data, as it was not readily available. To provide the data necessary to apply the validation process, a thermal emulator was designed and built that allowed control of all system inputs to the heat exchanger, while also providing the instrumentation to record all required data. A wide test matrix was chosen to fully encompass the expected operational envelope of the heat exchanger. Focus on the collection of experimental data was the minimization of uncertainty, as these uncertainties were amplified once they were propagated through the validation process.The validation process encompasses the completion of sensitivity and uncertainty analyses, uncertainty propagation, verification, and validation. Once these steps were completed using a set of non-ideal experimental data, uncertainty in the transient heat exchanger model is quantified. This manuscript proposes a way to complete the validation process without replicate data sets by utilizing known information about the physical process. At the completion of the process, both uncertainties and model form error are quantified for the system outputs and a statistical validation metric is applied. These outputs help to define whether or not the model captures the physical process to a satisfactory degree while also highlighting avenues for improvement if the uncertainty is deemed too large for the intended application."],"dc:format":["application/pdf","p.232","9.26 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1441064582"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws."],"dc:subject":["Engineering","Mechanical Engineering","verification","validation","transient heat exchanger model","first principles","thermal model","uncertainty","uncertainty propagation","sensitivity analysis"],"dc:title":["Verification and Validation of a Transient Heat Exchanger Model"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Renewable and Clean Energy"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Engineering (MSEgr)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-27T04:40:38Z"}