{"id":{"repo_id":"ohiolink","oai_identifier":"oai:etd.ohiolink.edu:wright1452960014"},"canonical_url":"https://search.ndltd.org/etd/ohiolink/oai:etd.ohiolink.edu:wright1452960014","repository":{"repo_id":"ohiolink","name":"OhioLINK","base_url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai"},"display":{"title":"Design of a low-cost wireless NIRS system withembedded Linux and a smartphone interface","abstract":"<p>Wireless near-infrared spectroscopy (NIRS) systems can help to reduce movement artifacts,and distraction due cables. Utilizing Embedded Linux (EL) can reduce size, developmenttime, cost of a project and allow portability. The goal of this project is to developa low-cost wireless small-sized NIRS system using EL and a Smartphone as the interface.This was achieved using a BeagleBone Black (BBB) with a deployed custom EL that: (1)controls two sources, (2) receives data from photodetectors (PDs), (3) processes, stores andtransmits data via Bluetooth to an Android Smartphone. This device was implemented inunder US$150 and its dimension was 9x5.5x4 cm. This is considerably cheaper and smallerthan most of commercial NIRS systems. It can be applied in functional NIRS researchand home care. More importantly our novel implementation of EL in NIRS will open upopportunities to further develop instrumentation using the modular nature of the Linux.","abstract_html":"&lt;p&gt;Wireless near-infrared spectroscopy (NIRS) systems can help to reduce movement artifacts,and distraction due cables. Utilizing Embedded Linux (EL) can reduce size, developmenttime, cost of a project and allow portability. The goal of this project is to developa low-cost wireless small-sized NIRS system using EL and a Smartphone as the interface.This was achieved using a BeagleBone Black (BBB) with a deployed custom EL that: (1)controls two sources, (2) receives data from photodetectors (PDs), (3) processes, stores andtransmits data via Bluetooth to an Android Smartphone. This device was implemented inunder US$150 and its dimension was 9x5.5x4 cm. This is considerably cheaper and smallerthan most of commercial NIRS systems. It can be applied in functional NIRS researchand home care. More importantly our novel implementation of EL in NIRS will open upopportunities to further develop instrumentation using the modular nature of the Linux.","abstract_has_math":false,"creators":["Dias, Diogo Da Silva"],"institution":"Wright State University","degree_name":"Master of Science in Biomedical Engineering (MSBME)","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Kashou, Nasser"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-26T05:27:49Z","subjects":["Biomedical Engineering","Computer Engineering","near-infrared spectroscopy","wireless","low-cost","embedded linux","portable","smartphone"],"languages":["English"],"rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1452960014","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"http://rave.ohiolink.edu/etdc/view?acc_num=wright1452960014","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aohiolink%3Aoai%3Aetd.ohiolink.edu%3Awright1452960014","prefix":"oai_dc"},"source_record":{"url":"https://etd.ohiolink.edu/acprod/odb_etd/ws/oai/oai?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aetd.ohiolink.edu%3Awright1452960014","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kashou, Nasser"]},{"key":"dc:creator","label":"Author","values":["Dias, Diogo Da Silva"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Wright State University / OhioLINK"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Biomedical Engineering (MSBME)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wright State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical Engineering","Computer Engineering","near-infrared spectroscopy","wireless","low-cost","embedded linux","portable","smartphone"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1452960014"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>Wireless near-infrared spectroscopy (NIRS) systems can help to reduce movement artifacts,and distraction due cables. Utilizing Embedded Linux (EL) can reduce size, developmenttime, cost of a project and allow portability. The goal of this project is to developa low-cost wireless small-sized NIRS system using EL and a Smartphone as the interface.This was achieved using a BeagleBone Black (BBB) with a deployed custom EL that: (1)controls two sources, (2) receives data from photodetectors (PDs), (3) processes, stores andtransmits data via Bluetooth to an Android Smartphone. This device was implemented inunder US$150 and its dimension was 9x5.5x4 cm. This is considerably cheaper and smallerthan most of commercial NIRS systems. It can be applied in functional NIRS researchand home care. More importantly our novel implementation of EL in NIRS will open upopportunities to further develop instrumentation using the modular nature of the Linux."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf","p.144","8.18 MB"]},{"key":"dc:title","label":"Title","values":["Design of a low-cost wireless NIRS system withembedded Linux and a smartphone interface"]}]}],"canonical_facts":{"dc:contributor":["Kashou, Nasser"],"dc:creator":["Dias, Diogo Da Silva"],"dc:date":["2015"],"dc:description":["<p>Wireless near-infrared spectroscopy (NIRS) systems can help to reduce movement artifacts,and distraction due cables. Utilizing Embedded Linux (EL) can reduce size, developmenttime, cost of a project and allow portability. The goal of this project is to developa low-cost wireless small-sized NIRS system using EL and a Smartphone as the interface.This was achieved using a BeagleBone Black (BBB) with a deployed custom EL that: (1)controls two sources, (2) receives data from photodetectors (PDs), (3) processes, stores andtransmits data via Bluetooth to an Android Smartphone. This device was implemented inunder US$150 and its dimension was 9x5.5x4 cm. This is considerably cheaper and smallerthan most of commercial NIRS systems. It can be applied in functional NIRS researchand home care. More importantly our novel implementation of EL in NIRS will open upopportunities to further develop instrumentation using the modular nature of the Linux."],"dc:format":["application/pdf","p.144","8.18 MB"],"dc:identifier":["http://rave.ohiolink.edu/etdc/view?acc_num=wright1452960014"],"dc:language":["English"],"dc:publisher":["Wright State University / OhioLINK"],"dc:rights":["unrestricted","This thesis or dissertation is protected by copyright: some rights reserved. It is licensed for use under a Creative Commons license. Specific terms and permissions are available from this document's record in the OhioLINK ETD Center."],"dc:subject":["Biomedical Engineering","Computer Engineering","near-infrared spectroscopy","wireless","low-cost","embedded linux","portable","smartphone"],"dc:title":["Design of a low-cost wireless NIRS system withembedded Linux and a smartphone interface"],"dc:type":["Electronic Thesis or Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Biomedical Engineering (MSBME)"],"thesis:institution_name":["Wright State University"]},"updated_at":"2026-11-26T05:27:49Z"}